Trouble Diagnosis ProcedureNIS001XG
WORK FLOW
1. CHECK IN
CHECK IN.
>> GO TO 2.
2. GET SYMPTOMS
Listen to custom

Page 1012 of 4647

INFINITI M35 2007  Factory Service Manual INTELLIGENT KEY SYSTEM
BL-79
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
15. CHECK OUT
CHECK OUT.
>> INSPECTION END
CONSULT-II Functions (INTELLIGENT KEY)NIS001XH
CONSULT-II can display

Page 1013 of 4647

INFINITI M35 2007  Factory Service Manual BL-80
INTELLIGENT KEY SYSTEM
Revision: 2007 April2007 M35/M45
CAUTION:
When CAN COMM  [U1000] and CONTROL UNIT (CAN) [U1010] are displayed, give priority to performing trouble diagnosis.
DATA MONITOR

Page 1016 of 4647

INFINITI M35 2007  Factory Service Manual INTELLIGENT KEY SYSTEM
BL-83
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
ACTIVE TEST
Test item Description
DOOR LOCK/UNLOCKThis test is able to check door lock/unlock operation.
The al

Page 1021 of 4647

INFINITI M35 2007  Factory Service Manual BL-88
INTELLIGENT KEY SYSTEM
Revision: 2007 April2007 M35/M45
POWER WINDOW DOWN FUNCTION MALFUNCTION
NOTE:
Before performing the diagnosis in the following table, check “Trouble Diagnosis Procedure

Page 1022 of 4647

INFINITI M35 2007  Factory Service Manual INTELLIGENT KEY SYSTEM
BL-89
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
Take away warning 
does not operate.Door open to close1. Check door switch.BL-94
2. Check inside key antenna.BL-

Page 1023 of 4647

INFINITI M35 2007  Factory Service Manual BL-90
INTELLIGENT KEY SYSTEM
Revision: 2007 April2007 M35/M45
Check CAN Communication SystemNIS001XL
1. CHECK SELF-DIAGNOSTIC RESULTS
CAUTION:
If CONSULT-II is used with no connection of CONSULT-II CO