INFINITI M35 2007  Factory Service Manual FUEL INJECTOR
EC-1389
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
FUEL INJECTORPFP:16600
Component DescriptionNBS005PV
The fuel injector is a small, precise solenoid valve. Whe

Page 2920 of 4647

INFINITI M35 2007  Factory Service Manual FUEL INJECTOR
EC-1391
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is mea

Page 2921 of 4647

INFINITI M35 2007  Factory Service Manual EC-1392
[VK45DE]
FUEL INJECTOR
Revision: 2007 April2007 M35/M45
2. CHECK OVERALL FUNCTION
 With CONSULT-II
1. Start engine.
2. Perform “POWER BALANCE” in “ACTIVE TEST” mode with
CONSULT-II.
3.

Page 2924 of 4647

INFINITI M35 2007  Factory Service Manual FUEL PUMP
EC-1395
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
FUEL PUMPPFP:17042
DescriptionNBS005Q1
SYSTEM DESCRIPTION
*: ECM determines the start signal status by the signals

Page 2926 of 4647

INFINITI M35 2007  Factory Service Manual FUEL PUMP
EC-1397
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM

Page 2942 of 4647

INFINITI M35 2007  Factory Service Manual IGNITION SIGNAL
EC-1413
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not u

Page 2944 of 4647

INFINITI M35 2007  Factory Service Manual IGNITION SIGNAL
EC-1415
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is m

Page 2946 of 4647

INFINITI M35 2007  Factory Service Manual IGNITION SIGNAL
EC-1417
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.