LT-92
INTERIOR ROOM LAMP
Revision: June 20062007 Versa
When key is inserted in the key switch and ignition knob switch, power is supplied (with Intelligent Key system)
through key switch and ignition knob switch terminal 1
to BCM terminal 37.
When ignition knob switch is pushed, power is supplied (with Intelligent Key system)
through key switch and ignition knob switch terminal 3
to Intelligent Key unit terminal 27.
With the ignition switch in the ON or START position, power is supplied
through 10A fuse [No. 6, located in fuse block (J/B)]
to BCM terminal 38.
Ground is supplied
to BCM terminal 67
through grounds M57 and M61.
When front door LH is opened, ground is supplied
to BCM terminal 47
through front door switch LH terminal 2
through case ground of front door switch LH.
When front door RH is opened, ground is supplied
to BCM terminal 12
through front door switch RH terminal 2
through case ground of front door switch RH.
When rear door LH is opened, ground is supplied
to BCM terminal 48
through rear door switch LH terminal 1
through case ground of rear door switch LH.
When rear door RH is opened, ground is supplied
to BCM terminal 13
through rear door switch RH terminal 1
through case ground of rear door switch RH.
When back door is opened, ground is supplied
to BCM terminal 43
through back door lock assembly (back door switch) terminal 3
through back door lock assembly (back door switch) terminal 4
through grounds B117, B132 and D402.
When front door LH is unlocked by front door key cylinder switch LH, the BCM receives a ground signal
to BCM terminal 7
through front door key cylinder switch LH terminal 3
through front door key cylinder switch LH terminal 2
through grounds M57 and M61.
When a signal, or combination of signals is received by BCM, ground is supplied
to room lamp terminal 2
through map lamp terminals 5 and 2 (with map lamp)
through BCM terminal 63.
With power and ground supplied, the interior room lamp illuminates.
SWITCH OPERATION
When map lamp switch is ON (with map lamp), ground is supplied
through grounds M57 and M61.
to map lamp terminal 1
Power is supplied
INTERIOR ROOM LAMP
LT-93
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: June 20062007 Versa
through BCM terminal 56
to map lamp terminal 4.
When interior room lamp switch is ON, ground is supplied
to interior room lamp terminal 1
through map lamp (with map lamp) terminal 7
through map lamp (with map lamp) terminal 1
through grounds M57 and M61.
Power is supplied
through BCM terminal 56
through map lamp (with map lamp) terminal 4
through map lamp (with map lamp) terminal 6
to room lamp terminal 3.
INTERIOR ROOM LAMP TIMER OPERATION
Without Intelligent Key System
When room lamp switch is in DOOR position, and when all conditions below are met, BCM performs timer
control (maximum 30 seconds) for room lamp ON/OFF.
In addition, when the interior room lamp turns ON or OFF there is gradual brightening or dimming over 1 sec-
ond.
Power is supplied
through 10A fuse [No. 14, located in fuse block (J/B)]
to key switch and key lock solenoid terminal 2.
When the key is removed from ignition key cylinder (key switch OFF), power will not be supplied to BCM termi-
nal 37.
When front door key cylinder switch LH is unlocked, ground is supplied
to BCM terminal 7
through front door key cylinder switch LH terminal 3
through front door key cylinder switch LH terminal 2
through grounds M57 and M61.
At the time that front door LH is opened, BCM detects that front door LH is unlocked. It determines that interior
room lamp timer operation condition is met, and turns the room lamp ON for 30 seconds.
When key is in ignition key cylinder (key switch ON),
Power is supplied
through key switch and key lock solenoid terminal 1
to BCM terminal 37.
When key is removed from key switch and key lock solenoid (key switch OFF), the power supply to BCM ter-
minal 37 is terminated. BCM detects that key has been removed, determines that interior room lamp timer
conditions are met, and turns the room lamp ON for 30 seconds.
When front door LH opens → closes, and the key is not inserted in the key switch and key lock solenoid (key
switch OFF), voltage at BCM terminal 47 changes between 0V (door open) → 12V (door closed). The BCM
determines that conditions for room lamp operation are met and turns the room lamp ON for 30 seconds.
Interior room lamp timer control is canceled under the following conditions:
Front door LH is locked (locked front door key cylinder switch LH).
Front door LH is opened (front door switch LH).
Ignition switch ON.
With Intelligent Key System
When the room lamp switch is in DOOR position, and when all conditions below are met, BCM performs timer
control (maximum 30 second) for room lamp ON/OFF.
In addition, when interior room lamp turns ON or OFF there is gradual brightening or dimming over 1 second.
Power is supplied
through 10A fuse (No. 31, located in fuse and fusible link box)
to key switch and ignition knob switch terminals 2 and 4.
LT-94
INTERIOR ROOM LAMP
Revision: June 20062007 Versa
When key is removed from ignition key cylinder (key switch OFF), power will not be supplied to BCM terminal
37.
When the ignition knob switch is released, power will not be supplied to Intelligent Key unit terminal 27.
When front door key cylinder switch LH is unlocked, ground is supplied
to BCM terminal 7
through front door key cylinder switch LH terminal 3
through front door key cylinder switch LH terminal 2
through grounds M57 and M61.
At the time the front door LH is opened, the BCM detects the front door LH is unlocked. It determines that the
interior room lamp timer operation conditions are met, and interior room lamp ON for 30 seconds.
When the key is in ignition key cylinder (key switch ON), or ignition knob switch is pushed, power is supplied
through key switch and ignition knob switch terminal 1
to BCM terminal 37, or
through key switch and ignition knob switch terminal 3
to Intelligent Key unit terminal 27.
When the key is removed from key switch (key switch OFF), power supply to BCM terminal 37 is terminated.
When the ignition knob switch is released, power supply to intelligent key unit is terminated. The BCM detects
that the key has been removed, determines that interior room lamp timer conditions are met, and turns room
lamp ON for 30 seconds.
When the front door LH opens → closes, and key is not inserted in key switch (or ignition knob switch is
released), BCM terminal 47 changes between 0V (door open) → 12V (door closed). BCM determines that
conditions for room lamp operation are met, and turns room lamp ON for 30 seconds.
Interior room lamp timer control is canceled under the following conditions:
Front door LH is locked (with keyfob or front door key cylinder switch LH).
Front door LH is opened (front door switch LH).
Ignition switch ON.
INTERIOR LAMP BATTERY SAVER CONTROL
If an interior room lamp is left ON, it will not be turned OFF even when door is closed.
BCM turns off interior lamp automatically to save battery 30 minutes after ignition switch is turned off.
After lamps are turned OFF by the battery saver system, the lamps illuminate again when
front door key cylinder switch LH is locked or unlocked
door is opened or closed
key is removed from ignition key cylinder or inserted in ignition key cylinder, or the ignition knob switch is
pushed or released.
Interior lamp battery saver control time period can be changed by the function setting of CONSULT-II.
INTERIOR ROOM LAMP
LT-101
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: June 20062007 Versa
Terminals and Reference Values for BCMEKS00HZN
Refer to BCS-12, "Terminals and Reference Values for BCM" .
How to Proceed With Trouble DiagnosisEKS00HZO
1. Confirm the symptom or customer complaint.
2. Understand operation description and function description. Refer to LT- 9 1 , "
System Description" .
3. Perform the preliminary check. Refer to LT-101, "
Preliminary Check" .
4. Check symptom and repair or replace the component.
5. Does the interior room lamp operate normally? If YES, GO TO 6. If NO, GO TO 4.
6. Inspection End
Preliminary CheckEKS00HZP
CHECK POWER SUPPLY AND GROUND CIRCUIT FOR BCM
Refer to BCS-16, "BCM Power Supply and Ground Circuit Check" .
CONSULT-II Function (BCM)EKS00HZQ
CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.
CONSULT-II START PROCEDURE
Refer to BCS-17, "CONSULT-II START PROCEDURE" .
WORK SUPPORT
Display Item List
Reference between “MODE” and “TIME” for “TURN ON/OFF”
DATA MONITOR
Display Item List
BCM diagnostic
test itemDiagnostic mode Description
Inspection by partWORK SUPPORTSupports inspections and adjustments. Commands are transmitted to the BCM
for setting the status suitable for required operation, input/output signals are
received from the BCM and received data is displayed.
DATA MONITOR Displays BCM input/output data in real time.
ACTIVE TEST Operation of electrical loads can be checked by sending drive signal to them.
SELF-DIAG RESULTS Displays BCM self-diagnosis results.
CAN DIAG SUPPORT MNTR The result of transmit/receive diagnosis of CAN communication can be read.
ECU PART NUMBER BCM part number can be read.
CONFIGURATION Performs BCM configuration read/write functions.
Item Description CONSULT-II
SET I/L D−UNLCK INTCONThe 30 second operating function of the interior room lamps can be selected
when the front door LH is released (unlocked). ON/OFF
ROOM LAMP ON TIME SETThe time in order to escalate illumination can be adjusted when interior room
lamps are turned on.MODE 1 – 7
ROOM LAMP OFF TIME SETThe time in order to diminish illumination can be adjusted when interior room
lamps are turned off.MODE 1 – 7
MODE12345 6 7
Time (sec.) 0.5 1 2 3 4 5 0
Monitor item Contents
IGN ON SW “ON/OFF”Displays “IGN position (ON)/OFF, ACC position (OFF)” judged from ignition switch sig-
nal.
KEY ON SW “ON/OFF” Displays “Key inserted (ON)/key removed (OFF)” status judged from key switch signal.
LT-102
INTERIOR ROOM LAMP
Revision: June 20062007 Versa
NOTE:
Vehicles without intelligent key system display this item, but cannot be monitored.
ACTIVE TEST
Display Item List
WORK SUPPORT
Display Item List
DATA MONITOR
Display Item List
DOOR SW - DR “ON/OFF”Displays status of front door LH as judged from front door switch LH signal. (Door is
open: ON/Door is closed: OFF)
DOOR SW - AS “ON/OFF”Displays “Door open (ON)/Door closed (OFF)” status, determined from front door switch
RH signal.
DOOR SW - RR “ON/OFF”Displays “Door open (ON)/Door closed (OFF)” status, determined from rear door switch
RH signal.
DOOR SW - RL “ON/OFF”Displays “Door open (ON)/Door closed (OFF) ” status, determined from rear door switch
LH signal.
LOCK STATUS “ON/OFF”Display status (door is locked: ON/door is unlocked: OFF) of front door lock actuator LH
(unlock sensor) judged from the front door lock actuator LH (unlock sensor) signal.
CDL LOCK SW “ON/OFF”Displays “Door locked (ON)/Door unlocked (OFF) status, determined from locking
detection switch in the front door LH.
CDL UNLOCK SW “ON/OFF”Displays “Door unlocked (OFF)” status, determined from locking detection switch in
front door RH.
I− KEY LOCK
NOTE“ON/OFF” Displays “Locked (ON)/Other (OFF)” status, determined from lock signal.
I− KEY UNLOCK
NOTE“ON/OFF” Displays “Unlocked (ON)/Other (OFF)” status, determined from unlock signal. Monitor item Contents
Test item Description
INT LAMP Interior room lamp can be operated by any ON-OFF operations.
Item Description CONSULT-II
ROOM LAMP TIMER SET Interior room lamp battery saver timer setting can be changed.MODE 1: 30 min.
MODE 2: 60 min.
ROOM LAMP BAT SAV SETInterior room lamp battery saver control mode can be changed in this mode.
Select interior room lamp battery saver control mode between ON and OFF.ON/OFF
Monitor item Contents
IGN ON SW “ON/OFF”Displays “IGN position (ON)/OFF, ACC position (OFF)” judged from ignition switch sig-
nal.
KEY ON SW “ON/OFF” Displays “Key inserted (ON)/key removed (OFF)” status judged from key switch signal.
DOOR SW - DR “ON/OFF”Displays status of front door LH as judged from front door switch LH signal. (Door is
open: ON/Door is closed: OFF)
DOOR SW - AS “ON/OFF”Displays “Door open (ON)/Door closed (OFF)” status, determined from front door switch
RH signal.
DOOR SW - RR “ON/OFF”Displays “Door open (ON)/Door closed (OFF)” status, determined from rear door switch
RH signal.
DOOR SW - RL “ON/OFF”Displays “Door open (ON)/Door closed (OFF) ” status, determined from rear door switch
LH signal.
LOCK STATUS “ON/OFF”Display status (door is locked: ON/door is unlocked: OFF) of front door lock actuator LH
(unlock sensor) judged from the front door lock actuator LH (unlock sensor) signal.
CDL LOCK SW “ON/OFF”Displays “Door locked (ON)/Door unlocked (OFF) status, determined from locking
detection switch in front door LH.
CDL UNLOCK SW “ON/OFF”Displays “Door unlocked (OFF)” status, determined from locking detection switch in pas-
senger’s door.
INTERIOR ROOM LAMP
LT-103
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: June 20062007 Versa
NOTE:
Vehicles without Intelligent Key system display this item, but cannot be monitored.
Interior Room Lamp Control Does Not Operate (With Map Lamp)EKS00HZR
1. CHECK EACH SWITCH
Select "BCM" on CONSULT-II. With "INT LAMP" data monitor, make
sure switches listed in display item list turn ON-OFF linked with
switch operation. Refer to LT- 1 0 1 , "
Display Item List" for switches
and their functions.
OK or NG
OK >> GO TO 2.
NG >> Inspect malfunctioning switch system.
2. ACTIVE TEST
1. Select “BCM” on CONSULT-II. Select “INT LAMP" active test.
2. When room lamp switch is in DOOR position, make sure room
lamp operates.
OK or NG
OK >> Replace BCM. Refer to BCS-25, "Removal and Installa-
tion of BCM" .
NG >> GO TO 3.
3. CHECK ROOM LAMP INPUT VOLTAGE
1. Turn ignition switch OFF.
2. Check voltage between interior room lamp harness connector
R7 terminal 3 and ground.
OK or NG
OK >> GO TO 6.
NG >> GO TO 4.
I− KEY LOCKNOTE“ON/OFF” Displays “Locked (ON)/Other (OFF)” status, determined from lock signal.
I− KEY UNLOCK
NOTE“ON/OFF” Displays “Unlocked (ON)/Other (OFF)” status, determined from unlock signal. Monitor item Contents
PKIB0263E
Room lamp should operate.
LKIA0092E
3 - Ground : Battery voltage.
WKIA5512E
LT-106
INTERIOR ROOM LAMP
Revision: June 20062007 Versa
3. CHECK ROOM LAMP INPUT VOLTAGE
1. Turn ignition switch OFF.
2. Check voltage between interior room lamp harness connector
R7 terminal 3 and ground.
OK or NG
OK >> GO TO 4.
NG >> GO TO 6.
4. CHECK ROOM LAMP
1. Disconnect room lamp connector.
2. Check continuity between room lamp terminals.
OK or NG
OK >> GO TO 5.
NG >> Check bulb. If OK, replace room lamp. Refer to LT-107, "
ROOM LAMP" .
5. CHECK ROOM LAMP CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between BCM harness connector M20 (A) ter-
minal 56 and room lamp harness connector R7 (B) terminal 3.
OK or NG
OK >> GO TO 6.
NG >> Repair harness or connector.
6. CHECK ROOM LAMP CIRCUIT
1. Disconnect BCM connector and room lamp connector.
2. Check continuity between BCM harness connector M20 (A) ter-
minal 63 and room lamp harness connector R7 (B) terminal 2.
OK or NG
OK >> Replace BCM if interior lamp does not work after setting
the connector again. Refer to BCS-25, "
Removal and
Installation of BCM" .
NG >> Repair harness or connector.3 - Ground : Battery voltage should exist.
WKIA5610E
Room lamp
Condition Continuity
Te r m i n a l
23 Room lamp switch is in
DOOR positionYe s
Room lamp switch is in OFF
positionNo
WKIA5609E
56 - 3 : Continuity should exist.
WKIA5559E
63 - 2 : Continuity should exist.
WKIA5560E
LT-108
ILLUMINATION
Revision: June 20062007 Versa
ILLUMINATIONPFP:27545
System DescriptionEKS00HZU
The control of the illumination lamps operation is dependent upon the position of the lighting switch. When the
lighting switch is placed in the 1ST or 2ND position, the BCM (body control module) receives input signal
requesting the illumination lamps to illuminate. This input signal is communicated to IPDM E/R (intelligent
power distribution module engine room) across CAN communication lines. CPU (central processing unit)
located in the IPDM E/R controls the tail lamp relay coil. This relay, when energized, directs power to the illu-
mination lamps, which then illuminate.
Power is supplied at all times
to ignition relay, located in IPDM E/R,
to tail lamp relay, located in IPDM E/R,
through 15A fuse (No. 52, located in IPDM E/R) and
through 20A fuse (No. 53, located in IPDM E/R)
to CPU located in IPDM E/R,
through 40A fusible link (letter g , located in fuse and fusible link box)
to BCM terminal 70, and
through 10A fuse [No. 8, located in fuse block (J/B)]
to BCM terminal 57.
With the ignition switch in the ON or START position, power is supplied
to ignition relay, located in IPDM E/R, and
through 10A fuse [No. 6, located in fuse block (J/B)]
to BCM terminal 38.
With the ignition switch in the ACC or ON position, power is supplied
through 10A fuse [No. 20, located in fuse block (J/B)]
to BCM terminal 11.
Ground is supplied
to BCM terminal 67
through grounds M57 and M61, and
to IPDM E/R terminals 39 and 59
through grounds E15 and E24.
ILLUMINATION OPERATION BY LIGHTING SWITCH
With the lighting switch in the 1ST or 2ND position, BCM receives input signal requesting the illumination
lamps to illuminate. This input signal is communicated to IPDM E/R across CAN communication lines. CPU
located in the IPDM E/R controls the tail lamp relay coil, which, when energized, directs power
through 10A fuse (No. 37, located in IPDM E/R)
through IPDM E/R terminal 29
to microphone terminal 3 (with Bluetooth)
to illumination control switch terminal 1
to glove box lamp terminal 1 (with glovebox lamp)
to audio unit terminal 9
to front air control terminal 5
to A/T device terminal 3 (without M/T)
to hazard switch terminal 3
to combination meter terminal 12
to door mirror remote control switch terminal 16, and
to main power window and door lock/unlock switch terminal 4.
Ground is supplied
to microphone terminal 2 (with Bluetooth)
to glove box lamp terminal 2 (with glove box lamp), and