2006 NISSAN PATROL lock

[x] Cancel search: lock

Page 963 of 1226

NISSAN PATROL 2006  Service Manual When installing oil jet, align oil jets boss with hole on cylin-
der block.
Oil jet bolt:
:30-40Nzm (3.1 - 4.1 kg-m, 22 - 30 ft-lb)
Turbocharger
+Before removing water tube, drain coolant ®rst.
+Be

Page 965 of 1226

NISSAN PATROL 2006  Service Manual Pull the negative pressure valve to open it. Check that it closes
completely when released.
CHECKING COOLING SYSTEM FOR LEAKS
Apply pressure to the cooling system by means of a tester to check
for lea

Page 966 of 1226

NISSAN PATROL 2006  Service Manual INSPECTION
1. Check for rusted or corroded body assembly and vane.
2. Check for excessive end play and rough operation.
INSTALLATION
+Remove liquid gasket from mating surface of pump housing
using a s

Page 967 of 1226

NISSAN PATROL 2006  Service Manual +Apply a continuous bead of liquid gasket to mating surface of
pump housing as shown.
a. Be sure diameter of liquid gasket is within 2.0 to 3.0 mm
(0.079 to 0.118 in) dia. range.
b. Attach pump housin

Page 968 of 1226

NISSAN PATROL 2006  Service Manual +Cut off tip of nozzle of liquid gasket at point shown in ®gure.
+Use Genuine Liquid Gasket or equivalent.
+Apply a continuous bead of liquid gasket to mating surface of
water inlet.
a. Be sure diame

Page 975 of 1226

NISSAN PATROL 2006  Service Manual Overheating Cause Analysis
Symptom Check items
Cooling
system parts
malfunctionPoor heat transferWater pump malfunction Worn or loose drive belt
Ð Thermostat stuck closed Ð
Damaged ®nsDust contamin

Page 977 of 1226

NISSAN PATROL 2006  Service Manual MAINTENANCE
SECTION
MA
CONTENTS
PRECAUTIONS AND PREPARATION............................1
Supplemental Restraint System (SRS) ``AIR
BAG and ``SEAT BELT PRE-TENSIONER...............1
Special Service

Page 979 of 1226

NISSAN PATROL 2006  Service Manual Shown below are Pre-delivery Inspection Items required for the new vehicle. It is recommended that
necessary items other than those listed here be added, paying due regard to the conditions in each
co