Page 2186 of 3383

POWER WINDOW SYSTEMGW-41
C
DE
F
G H
J
K L
M A
B
GW
Revision: November 2009 2006 QX56
Front Power Window Motor RH Circuit CheckEIS005Y2
1. CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH OUTPUT SIGNAL
1. Connect power window and door lock/unlock switch RH.
2. Turn ignition switch ON.
3. Check voltage between power window and door lock/unlock switch RH connector D105 terminals 8, 9 and ground.
OK or NG
OK >> GO TO 2.
NG >> Replace power window and door lock/unlock switch RH. Refer to EI-32, "
REMOVAL" .
2. CHECK FRONT POWER WINDOW MOTOR RH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect front power window motor RH and power window and door lock/unlock switch RH.
3. Check continuity between power window and door lock/unlock switch RH connector D105 terminals 8, 9 and front power win-
dow motor RH connector D104 terminals 1, 2.
OK or NG
OK >> Replace front power window motor RH. Refer to GW-66,
"FRONT DOOR GLASS REGULATOR" .
NG >> Repair or replace harness.
Limit Switch Circuit Check Front LHEIS005Y3
1. CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH LIMIT SIGNAL
1. Turn ignition switch ON.
2. Check voltage between main power window and door lock/ unlock switch connector D7 termimal 9 and ground.
OK or NG
OK >> Limit switch circuit is OK.
NG >> GO TO 2.
Connector Terminals
ConditionVoltage (V)
(Approx.)
(+) (-)
D105 9
Ground UP
0
DOWN Battery voltage
8 UP Battery voltage
DOWN 0
LIIA1261E
8 - 2 : Continuity should exist.
9 - 1 : Continuity should exist.
LIIA1262E
ConnectorTerminal
Condition Voltage (V)
(Approx.)
(+) (-)
D7 9 Ground Front power window LH is
between fully-open and just
before fully-closed position
(ON)
0
Front power window LH is
between just before fully-
closed position and fully-
closed position (OFF) 5
LIIA0339E
Page 2187 of 3383

GW-42
POWER WINDOW SYSTEM
Revision: November 20092006 QX56
2. CHECK FRONT POWER WINDOW MOTOR LH LIMIT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect front power window motor LH.
3. Turn ignition switch ON.
4. Check voltage between front power window motor LH connector D9 terminal 5 and ground.
OK or NG
OK >> GO TO 3.
NG >> GO TO 5.
3. CHECK LIMIT SWITCH GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check continuity between front power window motor LH connec- tor D9 terminal 6 and ground.
OK or NG
OK >> Replace front power window motor LH. Refer to GW-66,
"FRONT DOOR GLASS REGULATOR" .
NG >> GO TO 4.
4. CHECK HARNESS CONTINUITY
1. Disconnect main power window and door lock/unlock switch.
2. Check continuity between front power window motor LH connec- tor D9 terminal 6 and main power window and door lock/unlock
switch connector D7 terminal 2.
OK or NG
OK >> Replace main power window and door lock/unlock switch. Refer to EI-32, "
REMOVAL" .
NG >> Repair or replace harness.
5. CHECK HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect main power window and door lock/unlock switch.
3. Check continuity between front power window motor LH connec- tor D9 terminal 5 and main power window and door lock/unlock
switch connector D7 terminal 9.
OK or NG
OK >> Replace main power window and door lock/unlock switch. Refer to EI-32, "
REMOVAL" .
NG >> Repair or replace harness. 5 - Ground : Approx. 5V
LIIA0922E
6 - Ground
: Continuity should exist.
LIIA0923E
6 - 2: Continuity should exist.
LIIA0924E
5 - 9: Continuity should exist.
LIIA0925E
Page 2188 of 3383

POWER WINDOW SYSTEMGW-43
C
DE
F
G H
J
K L
M A
B
GW
Revision: November 2009 2006 QX56
Limit Switch Circuit Check Front RHEIS005Y4
1. CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH LIMIT SIGNAL
1. Turn ignition switch ON.
2. Check voltage between power window motor RH connector D105 terminal 15 and ground.
OK or NG
OK >> Limit switch circuit is OK.
NG >> GO TO 2.
2. CHECK FRONT POWER WINDOW MOTOR RH LIMIT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect front power window motor RH.
3. Turn ignition switch ON.
4. Check voltage between front power window motor RH connector D104 terminal 5 and ground.
OK or NG
OK >> GO TO 3.
NG >> GO TO 5.
3. CHECK LIMIT SWITCH GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check continuity between front power window motor RH con- nector D104 terminal 6 and ground.
OK or NG
OK >> Replace front power window motor RH. Refer to GW-66,
"FRONT DOOR GLASS REGULATOR" .
NG >> GO TO 4.
Connector Te r m i n a l s
Condition Voltage (V)
(Approx.)
(+) (-)
D105 15 Ground Front power window RH is
between fully-open and just
before fully-closed position
(ON)
0
Front power window RH is
between just before fully-
closed position and fully-
closed position (OFF) 5
LIIA1263E
5 - Ground
: Approx. 5V
LIIA0922E
6 - Ground: Continuity should exist.
LIIA0923E
Page 2190 of 3383

POWER WINDOW SYSTEMGW-45
C
DE
F
G H
J
K L
M A
B
GW
Revision: November 2009 2006 QX56
3. CHECK ENCODER GROUND
1. Turn ignition switch OFF.
2. Check continuity between front power window motor LH connec- tor D9 terminal 6 and ground.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. CHECK ENCODER GROUND CIRCUIT
1. Disconnect main power window and door lock/unlock switch.
2. Check continuity between front power window motor LH connec- tor D9 terminal 6 and main power window and door lock/unlock
switch connector D7 terminal 2.
OK or NG
OK >> Replace main power window and door lock/unlock switch. Refer to EI-32, "
REMOVAL" .
NG >> Repair or replace harness.
5. CHECK ENCODER SIGNAL
1. Connect front power window motor LH.
2. Turn ignition switch ON.
3. Check the signal between main power window and door lock/ unlock switch connector and ground with oscilloscope.
OK or NG
OK >> Replace main power window and door lock/unlock switch. Refer to EI-32, "REMOVAL" .
NG >> GO TO 6. 6 - Ground
: Continuity should exist.
LIIA0923E
6 - 2: Continuity should exist.
LIIA0924E
Connec-
tor Terminals
Condition Signal
(+) (-)
D7 13 Ground Opening
LIIA0364E
OCC3383D
Page 2192 of 3383

POWER WINDOW SYSTEMGW-47
C
DE
F
G H
J
K L
M A
B
GW
Revision: November 2009 2006 QX56
4. CHECK ENCODER GROUND CIRCUIT
1. Disconnect power window and door lock/unlock switch RH.
2. Check continuity between front power window motor RH con- nector D104 terminal 6 and power window and door lock/unlock
switch RH connector D105 terminal 3.
OK or NG
OK >> Replace power window and door lock/unlock switch RH. Refer to EI-32, "
REMOVAL" .
NG >> Repair or replace harness.
5. CHECK ENCODER SIGNAL
1. Connect front power window motor RH.
2. Turn ignition switch ON.
3. Check the signal between power window and door lock/unlock switch RH connector and ground with oscilloscope.
OK or NG
OK >> Replace power window and door lock/unlock switch RH. Refer to EI-32, "REMOVAL" .
NG >> GO TO 6.
6. CHECK ENCODER CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect front power window motor RH and power window and door lock/unlock switch RH.
3. Check continuity between front power window motor RH con- nector D104 terminal 3 and power window and door lock/unlock
switch RH connector D105 terminal 12.
OK or NG
OK >> Replace front power window motor RH. Refer to GW-66,
"FRONT DOOR GLASS REGULATOR" .
NG >> Repair or replace harness. 6 - 3 : Continuity should exist.
LIIA1264E
Connec-
tor Te r m i n a l s
Condition Signal
(+) (-)
D105 12 Ground Opening
LIIA1267E
OCC3383D
3 - 12 : Continuity should exist.
LIIA1268E
Page 2193 of 3383

GW-48
POWER WINDOW SYSTEM
Revision: November 20092006 QX56
Door Switch CheckEIS005Y7
1. CHECK FRONT DOOR SWITCH INPUT SIGNAL
With CONSULT-II
Check front door switches ( “DOOR SW-DR” and “DOOR SW-AS ” )
in “DATA MONITOR” mode with CONSULT-II. Refer to GW-34,
"DATA MONITOR" .
Without CONSULT-II
Check voltage between BCM connector and ground.
OK or NG
OK >> Front door switch is OK.
NG >> GO TO 2.
2. CHECK FRONT DOOR SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect front door switch LH or RH and BCM.
3. Check continuity between front door switch connector B8 (LH) or B108 (RH) terminal 2 and BCM connector M19 terminal 47
(LH) or connector M18 terminal 12 (LH).
4. Check continuity between front door switch connector B8 (LH) or B108 (RH) terminal 2 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
Monitor item Condition
DOOR SW-DR OPEN: ON
CLOSE: OFF
DOOR SW-AS OPEN: ON
CLOSE: OFF
Item Connector Terminals
ConditionVoltage (V)
(Approx.)
(+) (-)
Front RH M18 12 GroundOPEN
0
CLOSE Battery voltage
Front LH M19 47 OPEN
0
CLOSE Battery voltage
PIIA2464E
LIIA0946E
Front LH
2 - 47 : Continuity should exist.
Front RH
2 - 12 : Continuity should exist.
2 - Ground : Continuity should not exist.
LIIA0947E
Page 2194 of 3383

POWER WINDOW SYSTEMGW-49
C
DE
F
G H
J
K L
M A
B
GW
Revision: November 2009 2006 QX56
3. CHECK DOOR SWITCH
1. Disconnect front door switch LH or RH.
2. Check continuity between each front door switch terminal 2 and body ground part of front door switch.
OK or NG
OK >> Replace BCM. Refer to BCS-20, "BCM" .
NG >> Replace malfunctioning front door switch.
Front Door Lock Assembly LH (Key Cylinder Switch) CheckEIS005Y8
1. CHECK FRONT DOOR LOCK ASSEMBLY LH (KEY CYLINDER SWITCH) INPUT SIGNAL
With CONSULT-II
Check front door lock assembly LH (key cylinder switch) ( “KEY
CYL LK SW ”) in “DATA MONITOR” mode for “POWER DOOR
LOCK SYSTEM ” with CONSULT-II. Refer to GW-34, "
DATA
MONITOR" .
Check front door lock assembly LH (key cylinder switch) ( “KEY
CYL UN-SW ”) in “DATA MONITOR” mode for “POWER DOOR
LOCK SYSTEM ” with CONSULT-II. Refer to GW-34, "
DATA
MONITOR" .
Without CONSULT-II
Check voltage between main power window and door lock/unlock
switch connector and ground.
OK or NG
OK >> Front door lock assembly LH (key cylinder switch) is OK.
NG >> GO TO 2.
Terminal Door switch Continuity
2 Body ground part
of front door
switch Pushed
No
Released Yes
WIIA0644E
“KEY CYL LK-SW” should be “ON” when key inserted
in door key cylinder is turned to lock.
LIIA0047E
“KEY CYL UN-SW” should be “ON” when key inserted
in door key cylinder was turned to unlock.
LIIA0050E
ConnectorTe r m i n a l s
Key position Voltage (V)
(Approx.)
(+) (-)
D7 6
Ground Neutral / Unlock 5
Lock 0
4 Neutral / Lock 5
Unlock 0
LIIA1448E
Page 2196 of 3383

POWER WINDOW SYSTEMGW-51
C
DE
F
G H
J
K L
M A
B
GW
Revision: November 2009 2006 QX56
Power Window Serial Link Check Front LH and RHEIS005Y9
1. CHECK BUS OUTPUT SIGNAL
With CONSULT-II
Check door lock and unlock switch ( “LOCK SW DR/AS”, “UNLK SW
DR/AS ”) in DATA MONITOR mode for “MULTI REMOTE ENT” with
CONSULT-II. Refer to BL-27, "
DATA MONITOR" .
When door lock and unlock switch is turned to LOCK
When door lock and unlock switch is turned to UNLOCK
Without CONSULT-II
1. Remove key from ignition switch, and the door of driver side and passenger side is closed.
2. Check the signal between BCM connector and ground with oscilloscope when door lock and unlock switch (front LH and
front RH) is turned “LOCK ” or “UNLOCK ”.
3. Make sure signals which are shown in the figure below can be detected during 10 second just after door lock and unlock switch
(front LH and front RH) is turned “LOCK ” or “UNLOCK ”.
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
2. CHECK BCM BUS OUTPUT SIGNAL
Check power window serial link ( “POWER WINDOW DOWN”) in
“ACTIVE TEST ” mode with CONSULT-II. Refer to GW-34, "
ACTIVE
TEST" .
When “ACTIVE TEST ” is executed, is the window of driver side and
passenger side lowered.
OK or NG
OK >> Further inspection is necessary. Refer to GW-35, "Trou-
ble Diagnoses Symptom Chart" .
NG >> Replace BCM. Refer to .BCS-20, "
BCM"
LOCK SW DR/AS : ON
UNLK SW DR/AS : ON
LIIA0172E
ConnectorTerminals (Wire color)
Signal
(+) (-)
M18 22 GroundLIIA0391E
PIIA2344E