EC-340Revision: November 2009
DTC P0335 CKP SENSOR (POS)
2006 QX56
DTC P0335 CKP SENSOR (POS)PFP:23731
Component DescriptionUBS00H40
The crankshaft position sensor (POS) is located on the A/T assem-
bly facing the gear teeth (cogs) of the signal plate. It detects the fluc-
tuation of the engine revolution.
The sensor consists of a permanent magnet and Hall IC.
When the engine is running, the high and low parts of the teeth
cause the gap with the sensor to change.
The changing gap causes the magnetic field near the sensor to
change.
Due to the changing magnetic field, the voltage from the sensor
changes.
The ECM receives the voltage signal and detects the fluctuation of
the engine revolution.
ECM receives the signals as shown in the figure.
CONSULT-II Reference Value in Data Monitor ModeUBS00H41
Specification data are reference values.
On Board Diagnosis LogicUBS00H42
DTC Confirmation ProcedureUBS00H43
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 10.5V with igni-
tion switch ON.
PBIB0562E
PBIB2448E
MONITOR ITEM CONDITION SPECIFICATION
ENG SPEED
Run engine and compare CONSULT-II value with the tachometer indication. Almost the same speed as the
tachometer indication.
DTC No. Trouble diagnosis name
DTC detecting condition Possible cause
P0335
0335 Crankshaft position
sensor (POS) circuit
The crankshaft position sensor (POS) signal
is not detected by the ECM during the first
few seconds of engine cranking.
The proper pulse signal from the crankshaft
position sensor (POS) is not sent to ECM
while the engine is running.
The crankshaft position sensor (POS) signal
is not in the normal pattern during engine
running.
Harness or connectors
(The sensor circuit is open or shorted)
Crankshaft position sensor (POS)
Signal plate
DTC P0335 CKP SENSOR (POS)EC-343
C
DE
F
G H
I
J
K L
M A
EC
Revision: November 2009 2006 QX56
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnostic ProcedureUBS00H45
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body. Refer to EC-150, "
Ground Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
TER-
MINAL NO. WIRE
COLOR ITEM
CONDITION DATA (DC Voltage)
13 O Crankshaft position sensor
(POS) [Engine is running]
Warm-up condition
Idle speed
NOTE:
The pulse cycle changes depending on rpm at
idle. 1.0 - 2.0V
[Engine is running]
Engine speed: 2,000 rpm. 1.0 - 2.0V
111 W / B ECM relay
(Self shut-off) [Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition switch
OFF
0 - 1.5V
[Ignition switch: OFF]
More than a few seconds after turning ignition
switch OFF BATTERY VOLTAGE
(11 - 14V)
11 9
120 BR
BR
Power supply for ECM
[Ignition switch: ON] BATTERY VOLTAGE
(11 - 14V)
PBIB1041E
PBIB1042E
BBIA0354E
DTC P0340 CMP SENSOR (PHASE)EC-347
C
DE
F
G H
I
J
K L
M A
EC
Revision: November 2009 2006 QX56
DTC P0340 CMP SENSOR (PHASE)PFP:23731
Component DescriptionUBS00H48
The camshaft position sensor (PHASE) senses the protrusion of
exhaust valve cam sprocket to identify a particular cylinder. The
camshaft position sensor (PHASE) senses the piston position.
When the crankshaft position sensor (POS) system becomes inoper-
ative, the camshaft position sensor (PHASE) provides various con-
trols of engine parts instead, utilizing timing of cylinder identification
signals.
The sensor consists of a permanent magnet and Hall IC.
When engine is running, the high and low parts of the teeth cause
the gap with the sensor to change.
The changing gap causes the magnetic field near the sensor to
change.
Due to the changing magnetic field, the voltage from the sensor changes.
ECM receives the signals as shown in the figure.
On Board Diagnosis LogicUBS00H49
DTC Confirmation ProcedureUBS00H4A
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 10.5V with igni-
tion switch ON.
WITH CONSULT-II
1. Turn ignition switch ON.
PBIB0562E
PBIB2448E
DTC No. Trouble diagnosis nameDTC detecting condition Possible cause
P0340
0340 Camshaft position sen-
sor (PHASE) circuit
The cylinder No. signal is not sent to ECM
for the first few seconds during engine
cranking.
The cylinder No. signal is not sent to ECM
during engine running.
The cylinder No. signal is not in the normal
pattern during engine running.
Harness or connectors
(The sensor circuit is open or shorted)
Camshaft position sensor (PHASE)
Camshaft (Exhaust)
Starter motor (Refer to
SC-10, "START-
ING SYSTEM" .)
Starting system circuit (Refer to SC-10,
"STARTING SYSTEM" .)
Dead (Weak) battery
EC-350Revision: November 2009
DTC P0340 CMP SENSOR (PHASE)
2006 QX56
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnostic ProcedureUBS00H4C
1. CHECK STARTING SYSTEM
Turn ignition switch to START position.
Ye s o r N o
Yes >> GO TO 2.
No >> Check starting system. (Refer to SC-10, "
STARTING SYSTEM" .)
TER-
MINAL NO. WIRE
COLOR ITEM
CONDITION DATA (DC Voltage)
14 Y Camshaft position sensor
(PHASE) [Engine is running]
Warm-up condition
Idle speed
NOTE:
The pulse cycle changes depending on rpm at
idle. 1.0 - 4.0V
[Engine is running]
Engine speed: 2,000 rpm. 1.0 - 4.0V
111 W / B ECM relay
(Self shut-off) [Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition
switch OFF
0 - 1.5V
[Ignition switch: OFF]
More than a few seconds after turning igni-
tion switch OFF BATTERY VOLTAGE
(11 - 14V)
11 9
120 BR
BR
Power supply for ECM
[Ignition switch: ON] BATTERY VOLTAGE
(11 - 14V)
PBIB1039E
PBIB1040E
Does the engine turn over?
Does the starter motor operate?
EC-352Revision: November 2009
DTC P0340 CMP SENSOR (PHASE)
2006 QX56
5. CHECK CMP SENSOR (PHASE) GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Check harness continuity between CMP sensor (PHASE) terminal 1 and ground. Refer to wiring Diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F32, E2
Harness for open or short between CMP sensor (PHASE) and ground
>> Repair open circuit or short to power in harness or connectors.
7. CHECK CMP SENSOR (PHASE) INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal 14 and CMP sensor (PHASE) terminal 2. Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 8.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
8. CHECK CAMSHAFT POSITION SENSOR (PHASE)
Refer to EC-353, "
Component Inspection" .
OK or NG
OK >> GO TO 9.
NG >> Replace camshaft position sensor (PHASE).
9. CHECK INTERMITTENT INCIDENT
Refer to EC-144, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>> INSPECTION END
Continuity should exist.
Continuity should exist.
DTC P0420, P0430 THREE WAY CATALYST FUNCTIONEC-355
C
DE
F
G H
I
J
K L
M A
EC
Revision: November 2009 2006 QX56
8. Select “DTC & SRT CONFIRMATION ” then “SRT WORK SUP-
PORT ” mode with CONSULT-II.
9. Rev engine up to 2,000 to 3,000 rpm and hold it for 3 consecu- tive minutes then release the accelerator pedal completely.
If “INCMP ” of “CATALYST ” changed to “CMPLT ”, go to step 12.
10. Wait 5 seconds at idle.
11. Rev engine up to 2,000 to 3,000 rpm and maintain it until “INCMP ” of “CATALYST ” changes to “CMPLT ” (It will take
approximately 5 minutes).
If not “CMPLT ”, stop engine and cool it down to less than 70 °C
(158 °F) and then retest from step 1.
12. Select “SELF-DIAG RESULTS ” mode with CONSULT-II.
13. Confirm that the 1st trip DTC is not detected. If the 1st trip DTC is detected, go to EC-356, "
Diagnostic Proce-
dure" .
Overall Function CheckUBS00H4H
Use this procedure to check the overall function of the three way catalyst (manifold). During this check, a 1st
trip DTC might not be confirmed.
WITH GST
1. Start engine and warm it up to the normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
4. Let engine idle for 1 minute.
5. Open engine hood.
6. Set voltmeter probe between ECM terminals ECM terminals 55
[HO2S2 (bank 1) signal], 74 [HO2S2 (bank 2) signal] and
ground.
7. Keep engine speed at 2,500 rpm constant under no load.
8. Make sure that the voltage does not vary for more than 5 sec- onds.
If the voltage fluctuation cycle takes less than 5 seconds, go to
EC-356, "
Diagnostic Procedure" .
1 cycle: 0.6 - 1.0 → 0 - 0.3 → 0.6 - 1.0
PBIB1784E
PBIB1785E
SEF535Z
PBIB2056E
EC-358Revision: November 2009
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
2006 QX56
7. CHECK FUNCTION OF IGNITION COIL-II
1. Turn ignition switch OFF.
2. Disconnect spark plug and connect a known-good spark plug.
3. Crank engine for about 3 seconds, and recheck whether spark is generated between the spark plug and the grounded metal portion.
OK or NG
OK >> GO TO 8.
NG >> Check ignition coil, power transistor and their circuits. Refer to EC-618, "
IGNITION SIGNAL" .
8. CHECK SPARK PLUG
Check the initial spark plug for fouling, etc.
OK or NG
OK >> Replace spark plug(s) with standard type one(s). For spark plug type, refer to MA-18, "
Changing Spark Plugs"
.
NG >> 1. Repair or clean spark plug.
2. GO TO 9.
9. CHECK FUNCTION OF IGNITION COIL-III
1. Reconnect the initial spark plugs.
2. Crank engine for about three seconds, and recheck whether spark is generated between the spark plug and the grounded portion.
OK or NG
OK >> INSPECTION END
NG >> Replace spark plug(s) with standard type one(s). For spark plug type, refer to MA-18, "
Changing
Spark Plugs" .
10. CHECK FUEL INJECTOR
1. Turn ignition switch OFF.
2. Remove fuel injector assembly. Refer to EM-31, "
FUEL INJECTOR AND FUEL TUBE" .
Keep fuel hose and all fuel injectors connected to fuel injector gallery.
3. Disconnect all ignition coil harness connectors.
4. Reconnect all fuel injector harness connectors disconnected.
5. Turn ignition switch ON. Make sure fuel does not drip from fuel injector.
OK or NG
OK (Does not drip.)>>GO TO 11.
NG (Drips.)>>Replace the fuel injector(s) from which fuel is dripping. Spark should be generated.
SEF156I
Spark should be generated.
DTC P0441 EVAP CONTROL SYSTEMEC-361
C
DE
F
G H
I
J
K L
M A
EC
Revision: November 2009 2006 QX56
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and let it idle for at least 70 seconds.
4. Select “PURG FLOW P0441 ” of “EVAPORATIVE SYSTEM ” in “DTC CONFIRMATION ” mode with CON-
SULT-II.
5. Touch “START”.
If “COMPLETED” is displayed, go to step 7.
6. When the following conditions are met, “TESTING” will be displayed on the CONSULT-II screen. Maintain
the conditions continuously until “TESTING” changes to “COMPLETED ”. (It will take at least 35 seconds.)
If “TESTING” is not changed for a long time, retry from step 2.
7. Make sure that “OK ” is displayed after touching “SELF-DIAG RESULTS ”. If “NG” is displayed, refer to EC-
362, "Diagnostic Procedure" .
Overall Function CheckUBS00H4M
Use this procedure to check the overall monitoring function of the EVAP control system purge flow monitoring.
During this check, a 1st trip DTC might not be confirmed.
WITH GST
1. Lift up drive wheels.
2. Start engine (VDC switch OFF) and warm it up to normal operating temperature.
3. Turn ignition switch OFF, wait at least 10 seconds.
4. Start engine and wait at least 70 seconds.
5. Set voltmeter probes to ECM terminals 32 (EVAP control system
pressure sensor signal) and ground.
6. Check EVAP control system pressure sensor value at idle speed and note it.
7. Establish and maintain the following conditions for at least 1 minute.
8. Verify that EVAP control system pressure sensor value stays 0.1V less than the value at idle speed (mea- sured at step 6) for at least 1 second.
Selector lever Suitable position
VHCL SPEED SE 32 - 120 km/h (20 - 75 MPH)
ENG SPEED 500 - 3,000 rpm
B/FUEL SCHDL 1.0 - 12.0 msec
COOLAN TEMP/S 70 - 100°C (158 - 212° F)
PBIB0826E
Air conditioner switch ON
Headlamp switch ON
Rear window defogger switch ON
Engine speed Approx. 3,000 rpm
Gear position Any position other than P, N or R
PBIB1109E