2006 INFINITI QX56 battery

[x] Cancel search: battery

Page 1592 of 3383

INFINITI QX56 2006  Factory Service Manual DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-381
C
D E
F
G H
I
J
K L
M A
EC
Revision: November 2009 2006 QX56
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VA L

Page 1593 of 3383

INFINITI QX56 2006  Factory Service Manual EC-382Revision: November 2009
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
2006 QX56
On Board Diagnosis LogicUBS00H4T
DTC Confirmation ProcedureUBS00H4U
NOTE:
If DTC Confirmation

Page 1595 of 3383

INFINITI QX56 2006  Factory Service Manual EC-384Revision: November 2009
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
2006 QX56
Specification data are reference values and are measured between each terminal and ground.
Pu

Page 1596 of 3383

INFINITI QX56 2006  Factory Service Manual DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-385
C
D E
F
G H
I
J
K L
M A
EC
Revision: November 2009 2006 QX56
Diagnostic ProcedureUBS00H4W
1. CHECK EVAP CANISTER PURGE VOLUME

Page 1600 of 3383

INFINITI QX56 2006  Factory Service Manual DTC P0447 EVAP CANISTER VENT CONTROL VALVEEC-389
C
DE
F
G H
I
J
K L
M A
EC
Revision: November 2009 2006 QX56
DTC Confirmation ProcedureUBS00H52
NOTE:
If DTC Confirmation Procedure has been previously

Page 1602 of 3383

INFINITI QX56 2006  Factory Service Manual DTC P0447 EVAP CANISTER VENT CONTROL VALVEEC-391
C
DE
F
G H
I
J
K L
M A
EC
Revision: November 2009 2006 QX56
Specification data are reference values and are measured between each terminal and ground.

Page 1603 of 3383

INFINITI QX56 2006  Factory Service Manual EC-392Revision: November 2009
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
2006 QX56
3. CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect EVAP canist

Page 1609 of 3383

INFINITI QX56 2006  Factory Service Manual EC-398Revision: November 2009
DTC P0448 EVAP CANISTER VENT CONTROL VALVE
2006 QX56
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM gr