2006 INFINITI M35 ignition

[x] Cancel search: ignition

Page 1438 of 5621

INFINITI M35 2006  Factory Service Manual COMBINATION METERS
DI-5
C
D
E
F
G
H
I
J
L
MA
B
DI
Revision: 2006 January2006 M35/M45
COMBINATION METERSPFP:24814
System DescriptionNKS003TV
UNIFIED METER CONTROL UNIT
Speedometer, odo/trip meter, tach

Page 1441 of 5621

INFINITI M35 2006  Factory Service Manual DI-8
COMBINATION METERS
Revision: 2006 January2006 M35/M45
METER ILLUMINATION CONTROL
Meter illumination*  is controlled by the unified meter control unit.
Ring illumination under normal operation and

Page 1448 of 5621

INFINITI M35 2006  Factory Service Manual COMBINATION METERS
DI-15
C
D
E
F
G
H
I
J
L
MA
B
DI
Revision: 2006 January2006 M35/M45
Terminals and Reference Value for Combination MeterNKS003U0
Terminal 
No.Wire 
colorItemCondition
Reference value

Page 1449 of 5621

INFINITI M35 2006  Factory Service Manual DI-16
COMBINATION METERS
Revision: 2006 January2006 M35/M45
Terminals and Reference Value for Unified Meter and A/C Amp.NKS003U1
Te r m i n a l  
No.Wire 
colorItemCondition
Reference value
(Approx.)

Page 1450 of 5621

INFINITI M35 2006  Factory Service Manual COMBINATION METERS
DI-17
C
D
E
F
G
H
I
J
L
MA
B
DI
Revision: 2006 January2006 M35/M45
Self-Diagnosis Mode of Combination MeterNKS003U2
SELF-DIAGNOSIS FUNCTION
Odo/trip meter segment and dot matrix LCD

Page 1452 of 5621

INFINITI M35 2006  Factory Service Manual COMBINATION METERS
DI-19
C
D
E
F
G
H
I
J
L
MA
B
DI
Revision: 2006 January2006 M35/M45
Power Supply and Ground Circuit InspectionNKS003U6
1. CHECK FUSE
Check for blown fuses.
OK or NG
OK >> GO TO 2.
NG

Page 1454 of 5621

INFINITI M35 2006  Factory Service Manual COMBINATION METERS
DI-21
C
D
E
F
G
H
I
J
L
MA
B
DI
Revision: 2006 January2006 M35/M45
3. CHECK CONTINUITY BETWEEN COMBINATION METER AND UNIFIED METER AND A/C AMP. 
1. Turn ignition switch OFF.
2. Disc

Page 1455 of 5621

INFINITI M35 2006  Factory Service Manual DI-22
COMBINATION METERS
Revision: 2006 January2006 M35/M45
Engine Coolant Temperature Signal InspectionNKS003U9
Symptom: Water temperature gauge indication is malfunction.
1. CHECK UNIFIED METER AND