SE-32
AUTOMATIC DRIVE POSITIONER
Revision: 2006 January2006 M35/M45
24 W Seat sliding sensor signalON (seat sliding motor operation)
Other than above 0 or 5
25 W/Y Front lifting sensor signalON (front lifting motor operation)
Other than above 0 or 5
26 R/B Seat sliding switch forward signalON (seat sliding switch forward oper-
ation)0
Other than above Battery voltage
27 G/BSeat reclining switch forward sig-
nalON (seat reclining switch forward
operation)0
Other than above Battery voltage
28 Y/B Front lifting switch UP signalON (front lifting switch UP operation) 0
Other than above Battery voltage
29 L/B Rear lifting switch UP signalON (rear lifting switch UP operation) 0
Other than above Battery voltage
31 B/W Sensor ground — 0
32 W/B Ground (signal) — 0
33 W Power source (C/B) — Battery voltage
35 R/WSliding motor forward output sig-
nalSliding switch forward operation
(Motor operated)Battery voltage
Other than above 0
36 G/WReclining motor forward output
signalReclining switch forward operation
(Motor operated)Battery voltage
Other than above 0
37 Y/WFront lifting motor DOWN output
signalFront lifting switch down operation
(Motor operated)Battery voltage
Other than above 0
38 L/BRear lifting motor UP output sig-
nalRear lifting switch up operation (Motor
operated)Battery voltage
Other than above 0
39 L/WRear lifting motor DOWN output
signalRear lifting switch down operation
(Motor operated)Battery voltage
Other than above 0
40 R/B Power source (Fuse) — Battery voltage
42 R/BSliding motor backward output
signalSliding switch backward operation
(Motor operated)Battery voltage
Other than above 0 Te r m i -
nalWire
colorItem ConditionVoltage (V)
(Approx)
SIIA0690J
SIIA0691J
AUTOMATIC DRIVE POSITIONER
SE-33
C
D
E
F
G
H
J
K
L
MA
B
SE
Revision: 2006 January2006 M35/M45
Terminals and Reference Values for Automatic Drive Positioner Control UnitNIS0025Z
44 G/BReclining motor backward output
signalReclining switch backward operation
(Motor operated)Battery voltage
Other than above 0
45 Y/BFront lifting motor UP output sig-
nalFront lifting switch upward operation
(Motor operated)Battery voltage
Other than above 0
48 B Ground (power) — 0 Te r m i -
nalWire
colorItem ConditionVoltage (V)
(Approx)
Te r m i -
nal Wire
colorItem ConditionVoltage (V)
(Approx)
1 Y Tilt switch UP signalTilt switch is UP operation 0
Other than above 5
5L/RMirror sensor (RH vertical)
signalWhen mirror motor RH is UP or DOWN
operationChanges between 4.2 (close to perk)
0.5 (close to valley)
6LGMirror sensor (LH vertical)
signalWhen mirror motor LH is UP or DOWN
operationChanges between 4.2 (close to perk)
0.5 (close to valley)
7 L Tilt sensor signalTilt position : Top 1
Tilt position : Bottom 3.8
9 LG Memory switch 1 signalMemory switch 1 ON 0
Other than above 5
10 O UART LINE (TX) Tilt switch operated
11 RTelescopic switch forward
signalWhen telescopic switch is forward oper-
ation0
Other than above 5
12 R/GMemory switch indictor 1 sig-
nalWhen illuminate indictor 1 1
Other than above Battery voltage
13 PMemory switch indictor 2 sig-
nalWhen illuminate indictor 2 1
Other than above Battery voltage
14 L Mirror motor RH UP signalWhen mirror motor RH UP operation Battery voltage
Other than above 0
15 G Mirror motor RH LEFT signalWhen mirror motor RH LEFT operation Battery voltage
Other than above 0
16 W/LMirror motor LH DOWN sig-
nalWhen mirror motor LH DOWN opera-
tionBattery voltage
Other than above 0
Mirror motor LH RIGHT sig-
nalWhen mirror motor LH RIGHT opera-
tionBattery voltage
Other than above 0
17 LG Tilt switch DOWN signalWhen tilt switch is DOWN position 0
Other than above 5
SKIA0175E
SE-34
AUTOMATIC DRIVE POSITIONER
Revision: 2006 January2006 M35/M45
21 SBMirror sensor (RH horizon-
tal) signalWhen mirror motor RH is LEFT or
RIGHT operationChanges between 3.5 (close to left
edge) 0.5 (close to right edge)
22 O/LMirror sensor (LH horizontal)
signalWhen mirror motor LH is LEFT or
RIGHT operationChanges between 0.5 (close to left
edge) 3.5 (close to right edge)
23 GR Telescopic sensor inputTelescopic position : Top 4.6
Telescopic position : Bottom 0.4
24 BR/W Set switch signalSet switch ON 0
Other than above 5
25 LG/B Memory switch 2 signalMemory switch 2 ON 0
Other than above 5
26 P UART LINE (RX) Tilt switch is operated
27 WTelescopic switch backward
signalTelescopic switch turned to backward 0
Other than above 5
30 GRMirror motor RH DOWN sig-
nalWhen mirror motor RH DOWN opera-
tionBattery voltage
Other than above 0
Mirror motor RH RIGTH sig-
nalWhen mirror motor RH RIGHT opera-
tionBattery voltage
Other than above 0
31 BR Mirror motor LH UP signalWhen mirror motor LH UP operation Battery voltage
Other than above 0
32 V Mirror motor LH LEFT signalWhen mirror motor LH LEFT operation Battery voltage
Other than above 0
33 W Sensor power supply — 5
34 R Power source (Fuse) — Battery voltage
35 LG Tilt motor UP signalTilt switch is UP operation Battery voltage
Other than above 0
36 PTelescopic motor forward sig-
nalTelescopic switch is forward operation Battery voltage
Other than above 0
39 L Power source (C/B) — Battery voltage
40 B Ground — 0
41 Y Sensor ground — 0
42 G Tilt motor DOWN signalTilt switch is DOWN operation Battery voltage
Other than above 0
44 GTelescopic motor backward
signalTelescopic switch is backward opera-
tionBattery voltage
Other than above 0
48 B Ground — 0 Termi-
nal Wire
colorItem ConditionVoltage (V)
(Approx)
SKIA0175E
AUTOMATIC DRIVE POSITIONER
SE-37
C
D
E
F
G
H
J
K
L
MA
B
SE
Revision: 2006 January2006 M35/M45
DATA MONITOR
SELECTIOM FROM MEMU
SEAT LIFTER FR
[B2114]Seat lifting FR motorWhen any manual and automatic operations are not performed, if
any motor operations of seat lifting FR is detected for 0.1 second or
more, status is judged “Output error”.SE-46
SE-56
SEAT LIFTER RR
[B2115]Seat lifting RR motorWhen any manual and automatic operations are not performed, if
any motor operations of seat lifting RR is detected for 0.1 second or
more, status is judged “Output error”.SE-48
SE-58
TILT OUTPUT
[B2116]Tilt motorWhen any manual and automatic operations are not performed, if
any motor operations of seat tilt is detected for 0.1 second or more,
status is judged “Output error”.SE-50
TILT SENSOR
[B2118]Tilt sensorWhen driver seat control unit detects 0.1V or lower, or 4.9V or higher,
from tilt sensor for 0.5 seconds or more.SE-62
TELESCO SEN-
SOR
[B2119]Telescopic sensorWhen driver seat control unit detects 0.1V or lower, or 4.9V or higher,
from telescopic sensor for 0.5 seconds or more.SE-60
DETENT SW
[B2126]Detention SWWith the A/T selector lever in P position (Detente switch OFF), if the
vehicle speed of 7 km/h (4 MPH) or higher was input the detention
switch input system is judged malfunctioning.SE-85
UART COMM
[B2128]UART communica-
tionMalfunction is detected in UART communication.SE-87
CONSULT-II display Item Malfunction is detected when...Reference
page
Monitor item [OPERATION or UNIT] Contents
SET SW “ON/OFF” ON/OFF status judged from the setting switch signal is displayed.
MEMORY SW1 “ON/OFF” ON/OFF status judged from the seat memory switch 1 signal is displayed.
MEMORY SW2 “ON/OFF” ON/OFF status judged from the seat memory switch 2 signal is displayed.
SLIDE SW–FR “ON/OFF” ON/OFF status judged from the sliding switch (FR) signal is displayed.
SLIDE SW–RR “ON/OFF” ON/OFF status judged from the sliding switch (RR) signal is displayed.
RECLN SW–FR “ON/OFF” ON/OFF status judged from the reclining switch (FR) signal is displayed.
RECLN SW–RR “ON/OFF” ON/OFF status judged from the reclining switch (RR) signal is displayed.
LIFT FR SW–UP “ON/OFF” ON/OFF status judged from the FR lifting switch (UP) signal is displayed.
LIFT FR SW–DN “ON/OFF” ON/OFF status judged from the FR lifting switch (DOWN) signal is displayed.
LIFT RR SW–UP “ON/OFF” ON/OFF status judged from the RR lifting switch (UP) signal is displayed.
LIFT RR SW–DN “ON/OFF” ON/OFF status judged from the RR lifting switch (DOWN) signal is displayed.
MIR CON SW–UP “ON/OFF”ON/OFF status judged from the door mirror remote control switch (UP) signal is
displayed.
MIR CON SW–DN “ON/OFF”ON/OFF status judged from the door mirror remote control switch (DOWN) signal
is displayed.
MIR CON SW–RH “ON/OFF”ON/OFF status judged from the door mirror remote control switch (RIGHT) signal
is displayed.
MIR CON SW–LH “ON/OFF”ON/OFF status judged from the door mirror remote control switch (LEFT) signal is
displayed.
MIR CHNG SW–R “ON/OFF”ON/OFF status judged from the door mirror remote control switch (switching to
RIGHT) signal is displayed.
MIR CHNG SW–L “ON/OFF”ON/OFF status judged from the door mirror remote control switch (switching to
LEFT) signal is displayed.
TILT SW-UP “ON/OFF” ON/OFF status judged from the tilt switch (UP) signal is displayed.
TILT SW-DOWN “ON/OFF” ON/OFF status judged from the tilt switch (DOWN) signal is displayed.
TELESCO SW-FR “ON/OFF” ON/OFF status judged from the telescoping switch (FR) signal is displayed.
TELESCO SW-RR “ON/OFF” ON/OFF status judged from the telescoping switch (RR) signal is displayed.
SE-38
AUTOMATIC DRIVE POSITIONER
Revision: 2006 January2006 M35/M45
ACTIVE TEST
CAUTION:
During vehicle driving, do not perform active test.
NOTE:
If active test is performed, reset seat memory and key fob interlock drive positioner after performing work.
DISPLAY ITEM LIST
WORK SUPPORT
The seat slide amount at entry/exit operation setting can be changed by CONSULT-II. Refer to SE-16, "SET-
TING CHANGE FUNCTION" .
DETENT SW “ON/OFF”The selector lever position “OFF (P position) / ON (other than P position)” judged
from the detention switch signal is displayed.
STARTER SW “ON/OFF”Ignition key switch ON (START, ON) /OFF (IGN, ACC, or OFF) status judged from
the ignition switch signal is displayed.
SLIDE PULSE —Value (32768) when battery connects is as standard. If it moves backward, the
value increases. If it moves forward, the value decreases.
RECLN PULSE —Value (32768) when battery connects is as standard. If it moves backward, the
value increases. If it moves forward, the value decreases.
LIFT FR PULSE —Value (32768) when battery connects is as standard. If it moves DOWN, the value
increases. If it moves UP, the value decreases.
LIFT RR PULSE —Value (32768) when battery connects is as standard. If it moves DOWN, the value
increases. If it moves UP, the value decreases.
MIR/SEN RH U–D “V” Voltage output from RH door mirror sensor (UP/DOWN) is displayed.
MIR/SEN RH R–L “V” Voltage output from RH door mirror sensor (LH/RH) is displayed.
MIR/SEN LH U–D “V” Voltage output from LH door mirror sensor (UP/DOWN) is displayed.
MIR/SEN LH R–L “V” Voltage output from LH door mirror sensor (LH/RH) is displayed. Monitor item [OPERATION or UNIT] Contents
Test item Description
TILT MOTOR The tilt motor is activated by receiving the drive signal.
TELESCO MOTOR The telescopic motor is activated by receiving the drive signal.
SEAT SLIDE The sliding motor is activated by receiving the drive signal.
SEAT RECLINING The reclining motor is activated by receiving the drive signal.
SEAT LIFTER FR The front lifting motor is activated by receiving the drive signal.
SEAT LIFTER RR The rear lifting motor is activated by receiving the drive signal.
MIRROR MOTOR RHThe RH mirror motor moves the mirror UP/DOWN and LEFT/RIGHT by receiving the drive
signal.
MIRROR MOTOR LHThe LH mirror motor moves the mirror UP/DOWN and LEFT/RIGHT by receiving the drive
signal.
MEMORY SW INDCTR The memory switch indicator is lit by receiving the drive signal.
AUTOMATIC DRIVE POSITIONER
SE-39
C
D
E
F
G
H
J
K
L
MA
B
SE
Revision: 2006 January2006 M35/M45
Work Flow NIS00261
1. Check the symptom and customer's requests.
2. Understand the system description. Refer to SE-12, "
System Description" .
3. Perform the self-diagnosis results, using CONSULT-II. Refer to SE-35, "
CONSULT-II Function (AUTO
DRIVE POS.)" .
4. Repair or replace depending on the self-diagnostic results.
5. Based on the trouble diagnosis chart, repair or replace the cause of the malfunction. Refer to SE-39,
"Symptom Chart" .
6. Does the automatic drive positioned system operate normally?
If it is normal, GO TO 8.
If it is not normal, GO TO 3.
7. INSPECTION END
Symptom ChartNIS00262
NOTE:
Always check the “Work flow” before performing diagnosis in the following table, Refer to SE-39, "
Work Flow"
.
Symptom Diagnoses / service procedureReference
page
All of automatic operation dose not operate.1. BCM power supply and ground circuit check.SE-41
2. Driver seat control unit power supply and ground cir-
cuit check.SE-42
3. Automatic drive positioner control unit power supply
and ground circuit check.SE-43
Sliding function does not operate (automatically and man-
ually).Sliding motor circuit check SE-44
Reclining function does not operate (automatically and
manually).Reclining motor circuit check SE-45
Front lifting function does not operate (automatically and
manually).Front lifting motor circuit checkSE-46
Rear lifting function not operate (automatically and manu-
ally).Rear lifting motor circuit checkSE-48
Tilt function does not operate (automatically and manu-
ally).Tilt motor circuit checkSE-50
Telescopic function does not operate (automatically and
manually).Telescopic motor circuit checkSE-49
Sliding function does not operate automatically. Sliding sensor circuit checkSE-52
Reclining function does not operate automatically. Reclining sensor circuit checkSE-54
Front lifting function does not operate automatically. Front lifting sensor circuit checkSE-56
Rear lifting function does not operate automatically. Rear lifting sensor circuit checkSE-58
Tilt function does not operate automatically. Tilt sensor circuit checkSE-62
Telescopic function does not operate automatically. Telescopic sensor circuit checkSE-60
Sliding function does not operate manually. Sliding switch circuit checkSE-68
Reclining function does not operate manually. Reclining switch circuit checkSE-70
Front lifting function does not operate manually. Lifting switch (front) circuit checkSE-72
Rear lifting function does not operate manually. Lifting switch (rear) circuit checkSE-74
Tilt function does not operate manually. Tilt switch circuit checkSE-78
Telescopic function does not operate manually. Telescopic switch circuit checkSE-76
All of seat operation dose not operate manually. Power seat switch ground circuit check.SE-75
SE-40
AUTOMATIC DRIVE POSITIONER
Revision: 2006 January2006 M35/M45
Only seat memory and set switch operation does not
operate.1. Perform storing memorySE-13
2. Seat memory and set switch circuit checkSE-80
Seat memory indicator lamps 1 and 2 do not illuminate. Seat memory indicator lamp circuit checkSE-81
Entry/Exiting operation does not operated.1. Check system setting.SE-162. Perform initialization.SE-16
3. Front door switch (driver side) circuit checkSE-86
LH or RH door mirror face does not produce the stored
angle, during the memory operation.1. Door mirror sensor power supply and ground circuit
checkSE-832. Door mirror sensor LH circuit checkSE-63
3. Door mirror sensor RH circuit checkSE-66
4. Replace automatic drive positioner control unitSE-11
Intelligent key interlock operation does not operate.
(Other automatic operation and Intelligent Key system are
normal)Perform storing memorySE-13
Lumber support does not operate Lumber support circuit checkSE-89
Symptom Diagnoses / service procedureReference
page
SE-52
AUTOMATIC DRIVE POSITIONER
Revision: 2006 January2006 M35/M45
4. CHECK AUTOMATIC DRIVE POSITIONER CONTROL UNIT OUTPUT SIGNAL
1. Connect automatic drive positioner control unit connector and tilt motor connector.
2. Check voltage between automatic drive positioner control unit connector and ground.
OK or NG
OK >> Replace tilt motor.
NG >> Replace automatic drive positioner control unit.
Sliding Sensor Circuit CheckNIS0026D
1. CHECK FUNCTION
With CONSULT-II
Check operation with “SLIDE PULSE” on the DATA MONITOR to make sure the pulse changes.
Without CONSULT-II
1. Turn ignition switch OFF.
2. Check signal between driver seat control unit connector and
ground, with oscilloscope.
OK or NG
OK >> Sliding sensor circuit is OK.
NG >> GO TO 2.
Automatic
drive posi-
tioner C/U
connectorTerminals
Tilt switch conditionVoltage (V)
(Approx.)
(+) (–)
M735
GroundUP Battery voltage
Other than above 0
42DOWN Battery voltage
Other than above 0
PIIB6143E
Monitor item [OPERATION or UNIT] Contents
SLIDE PULSE —The seat sliding position (pulse) judged
from the sliding sensor signal is dis-
played
PIIA4558E
Driver seat
control unit
connectorTerminals
ConditionSignal
(Reference value)
(+) (–)
B204 24 GroundSliding
motor
operation
PIIB6147E