± DIAGNOSTICSWIRELESS DOOR LOCK CONTROL SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
7 REGISTER RECOGNITION CODE
(a) Check that the system can switch to rewrite mode or add mode and whether a recognition code can
be registered.
NG Go to step 16
OK
NORMAL (CARRY OUT INSPECTION OF FUNCTIONS)
8 SIMPLY CHECK TRANSMITTER BATTERY
(a) After replacing the transmitter battery with a new or normal one, check that the doors can lock and
unlock using the transmitter LOCK/UNLOCK switch.
NG REPLACE TRANSMITTER SUB±ASSY MODULE
SET DOOR CONTROL
OK
REPLACE TRANSMITTER BATTERY
9 CHECK RESPONSE OF DOOR CONTROL RECEIVER
(a) When a new or normal door control transmitter switch for the same type vehicle is held down, check
that a diagnosis of unmatching recognition code is output.
NG Go to step 13
OK
REPLACE TRANSMITTER SUB±ASSY MODULE SET DOOR CONTROL
10 CONFIRM INPUT METHOD OF SELF±DIAGNOSTIC MODE
(a) When the method for switching the system to self±diagnostic mode works, proceed to A.
(b) When the method for switching the system to self±diagnostic mode does not work, proceed to B.
B Go to step 6
A
Page 3309 of 5135

730EY±02
± THEFT DETERRENT & DOOR LOCKTRANSMITTER SUB±ASSY MODULE SET DOOR
CONTROL73±21
AVENSIS REPAIR MANUAL (RM1018E)
REGISTRATION
1. REGISTER RECOGNITION CODE
HINT:
Register the recognition code when replacing the door control transmitter or the door control receiverr.
The add mode is used to register new recognition codes while still retaining codes already registered.
This mode is used when a new transmitter is added. If the number of registered codes exceeds 4, the
previously registered codes will be erased in order, starting from the first registered code.
The rewrite mode is used to erase all the previously registered recognition codes in order to register
new recognition codes. This mode is used when the transmitter or the door control receiver is ex-
changed for a new one.
The confirmation mode is used to confirm how many recognition codes have already been registered
before an additional registration of a recognition codes.
The all clear mode is used to erase all the registered codes and disables the wireless door lock func-
tion. This mode is used when the transmitter is lost.
All the following registration procedures must be performed in order continuously.
Page 3311 of 5135
Within 40 sec.
ON
LOCK
ON±LOCK operation: 1 time
Add Mode
Rewrite Mode
ON±LOCK operation: 2 times
Confirmation Mode
ON±LOCK operation: 3 times
All Clear Mode
ON±LOCK operation: 5 times Number of ON±LOCK operations of ignition switch:Turn ignition switch from LOCK to ON and back to LOCK at approximately
1 second intervals according to the number of times shown below.
Mode Selection:
If the number of the ON±LOCK operations of the ignition switch
is 0, 4 or 6 or more, there will be no response (power door lock and
unlock operation) to inform which mode has been selected.
Remove key from ignition key cylinder.
8. 7.
Within 3 sec.
T1T1: Approx. 1 sec.
Continued from previous page
Continued on next page
ON
LOCKT1 T1
ON
LOCKT1 T1
ON
LOCKT1 T1
± THEFT DETERRENT & DOOR LOCKTRANSMITTER SUB±ASSY MODULE SET DOOR
CONTROL73±23
AVENSIS REPAIR MANUAL (RM1018E)
Page 3312 of 5135

Continued from previous page
Integration relay automatically performs power door LOCK±UNLOCK operation to inform
which mode has been selected.
Response to selected mode (Power door lock operation):
UNLOCKLOCK
LOCK±UNLOCK operation: 1 time Add Mode
Rewrite Mode
Confirmation Mode
All Clear Mode
T1T1: Approx. 1 sec.
T1 T1
T2
T2
T1 T1
LOCK±UNLOCK operation: 2 times
LOCK±UNLOCK operation: The number of registered codes (1 ± 5 times)
LOCK±UNLOCK operation: 5 timesUNLOCKLOCK
UNLOCKLOCK
UNLOCKLOCK
Continued on next page
Registration procedures are completed.
HINT:
In the confirmation mode, when LOCK±UNLOCK operation is performed twice, the
number of registered recognition codes is 2.
In the confirmation mode, when 0 codes are registered, LOCK±UNLOCK operation
is automatically performed 5 times.T2: Approx. 2 sec.
Confirmation Mode and
All Clear ModeAdd Mode or
Rewrite Mode Within
3 sec.
Within
40 sec.
1st time 2nd time
73±24± THEFT DETERRENT & DOOR LOCKTRANSMITTER SUB±ASSY MODULE SET DOOR
CONTROL
AVENSIS REPAIR MANUAL (RM1018E)
Page 3313 of 5135

Continued from previous page
Press either LOCK or UNLOCK switch on transmitter once. 9.
Within 40 sec.
Proceed to flow chart to finish
registration.
Press the same switch again.
LOCK±UNLOCK Occurs Once
Registration of recognition code has
been completed. Response to registration completion:
T1: Approx. 1 sec. LOCK±UNLOCK Occurs Twice
Registration of recognition code has failed. 10.
LOCK
UNLOCK
T1
LOCK
UNLOCKT1 T1
Within
40 sec.
If other transmitter is to be registered. Within
3 sec.
Registration of recognition codes (add mode and rewrite mode) is completed.
Integration relay automatically performs power door LOCK±UNLOCK operation to show
whether registration has been completed correctly or not.
HINT:
4 recognition codes can be registered
at once. HINT:
If LOCK±UNLOCK operation is performed twice, registration of recognition code has
failed. Perform registration procedures by beginning once again.
Within
3 sec.
Open a door.
Insert key into ignition key cylinder. Perform either of the following.
± THEFT DETERRENT & DOOR LOCKTRANSMITTER SUB±ASSY MODULE SET DOOR
CONTROL73±25
AVENSIS REPAIR MANUAL (RM1018E)