EC-1040
[YD (WITH EURO-OBD)]
TROUBLE DIAGNOSIS
2. “MANU TRIG”
–If the malfunction is displayed as soon as “DATA MONITOR” is selected, reset CONSULT-II to “MANU
TRIG”. By selecting “MANU TRIG” you can monitor and store the data. The data can be utilized for further
diagnosis, such as a comparison with the value for the normal operating condition.
FUNCTION TEST
This mode is used to inform customers of their vehicle condition of periodic maintenance.
Generic Scan Tool (GST) FunctionEBS011UO
DESCRIPTION
Generic Scan Tool (OBDII scan tool) complying with ISO 15031-4
has 8 different functions explained below.
ISO9141 is used as the protocol.
The name “GST” or “Generic Scan Tool” is used in this service man-
ual.
FUNCTION
SEF720X
SEF139P
Diagnostic test mode Function
Service $01 READINESS TESTSThis diagnostic service gains access to current emission-related data values, including
analog inputs and outputs, digital inputs and outputs, and system status information.
Service $02 (FREEZE DATA)This diagnostic service gains access to emission-related data value which were stored by
ECM during the freeze frame. For details, refer to EC-999, "
FREEZE FRAME DATA" .
Service $03 DTCsThis diagnostic service gains access to emission-related power train trouble codes which
were stored by ECM.
TROUBLE DIAGNOSIS
EC-1411
[YD (WITHOUT EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
–If the malfunction is displayed as soon as “DATA MONITOR” is selected, reset CONSULT-II to “MANU
TRIG”. By selecting “MANU TRIG” you can monitor and store the data. The data can be utilized for further
diagnosis, such as a comparison with the value for the normal operating condition.
FUNCTION TEST
This mode is used to inform customers of their vehicle condition of periodic maintenance.
CONSULT-II Reference Value in Data Monitor ModeEBS011XN
Remarks:
Specification data are reference values.
Specification data are output/input values which are detected or supplied by the ECM at the connector.
* Specification data may not be directly related to their components signals/values/operations.
SEF720X
MONITOR ITEM CONDITION SPECIFICATION
CKPS-RPM (TDC)
Run engine and compare CONSULT-II value with the tachometer
indication.Almost the same speed as the
tachometer indication
COOLAN TEMP/S
Engine: After warming up More than 70°C (158°F)
VHCL SPEED SE
Turn drive wheels and compare CONSULT-II value with the speed-
ometer indicationAlmost the same speed as the
speedometer indication
FUEL TEMP SEN
Engine: After warming up More than 40°C (104°F)
ACCEL POS SEN*
Ignition switch: ON
(Engine stopped)Accelerator pedal: fully released 0.2 - 0.7V
Accelerator pedal: fully depressed 3.9 - 4.9V
ACCEL SEN 2*
Ignition switch: ON
(Engine stopped)Accelerator pedal: fully released 0.1 - 0.4V
Accelerator pedal: fully depressed 1.9 - 2.4V
MAS AIR/FL SE*
Engine: After warming up
Air conditioner switch: OFF
Shift lever: Neutral position
No-loadIdle 1.5 - 2.0V
2,000 rpm 2.2 - 2.7V
BATTERY VOLT
Ignition switch: ON (Engine stopped) 11 - 14V