SENSOR INSPECTION FOR AIR CONDITIONING SYSTEM ± AC005-04 December 16, 2004
Page 12 of 12
6. Inspect Room Humidity Sensor.
Measure the humidity and output
voltage of the humidity sensor when
the sensor is installed on the vehicle
and the temperature at the humidity
sensor position (room temperature
sensor position) is 775F (255C).
If the output voltage is within the
specifications according to the graph
and table below, the sensor is normal.
HINT:
For the inspection procedure of the
room temperature sensor, refer to
ªRoom Temperature Sensor Inspection
Procedureº in this bulletin.
A. Turn the ignition switch to the
ON position.
B. Measure the voltage between
terminal VO (3) and GND (2) of
the room humidity sensor.
C. Measure the humidity and voltage
when the room temperature
(humidity sensor position) is 775F
(255C). According to the result,
determine whether the sensor is
normal or not.
HUMIDITY (% RH)OUTPUT VOLTAGE
AT 775F (255C)
100.70 to 1.08 V
200.72 to 1.57 V
301.13 to 1.95 V
401.61 to 2.24 V
501.99 to 2.46 V
602.26 to 2.66 V
702.48 to 2.85 V
802.68 to 3.04 V
902.87 to 3.05 V
Inspection
Procedure
(Continued)
VOGND
Resistance
kW
3.50
3.00
2.50
2.00
1.50
1.00
0.50
0.00
32
(0)68
(20)104
(40)140
(60)
Temperature 5F (5C) Max
Min
176
(80)212
(100)