Page 886 of 3419

AUTOMATIC BACK DOOR SYSTEM
BL-119
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
2. BACK DOOR CLOSE SWITCH SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While operating the back door close switch, check voltage
between back door control unit connector B55 terminal 8 and
ground.
OK or NG
OK >> Back door close switch is OK.
NG >> GO TO 3.
3. BACK DOOR CLOSE SWITCH CIRCUIT INSPECTION
1. Disconnect back door close switch and back door control unit connector.
2. Check continuity between back door close switch connector B63
terminal 1 and back door control unit connector B55 terminal 8.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
4. BACK DOOR CLOSE SWITCH GROUND INSPECTION
Check continuity between back door close switch connector B63 ter-
minal 3 and ground.
OK or NG
OK >> Replace the back door close switch.
NG >> Repair or replace harness.
Back Door Close (Cancel) Switch System InspectionEIS0 08 RF
1. BACK DOOR CLOSE SWITCH FUNCTION INSPECTION
Check back door close (cancel) switch using switch operation.
OK or NG
OK >> Back door close switch is OK.
NG >> GO TO 2.
Te r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
8 GroundBack door
close switchON 0
OFF Battery voltage
LIIA0805E
1 - 8 : Continuity should exist.
LIIA1066E
3 - Ground : Continuity should exist.
WIIA0602E
Page 887 of 3419

BL-120
AUTOMATIC BACK DOOR SYSTEM
Revision: October 20052005 QX56
2. BACK DOOR CLOSE (CANCEL) SWITCH SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While operating the back door close (cancel) switch, check volt-
age between back door control unit connector B55 terminal 13
and ground.
OK or NG
OK >> Back door close switch is OK.
NG >> GO TO 3.
3. BACK DOOR CLOSE (CANCEL) SWITCH CIRCUIT INSPECTION
1. Disconnect back door close switch and back door control unit connector.
2. Check continuity between back door close switch connector B63
terminal 5 and back door control unit connector B55 terminal 13.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
4. BACK DOOR CLOSE SWITCH GROUND INSPECTION
Check continuity between back door close switch connector B63 ter-
minal 3 and ground.
OK or NG
OK >> Replace the back door close switch.
NG >> Repair or replace harness.
Te r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
13 GroundBack door
close switchCancel (ON) 0
Cancel (OFF) 9
LIIA1068E
5 - 13 : Continuity should exist.
LIIA1069E
3 - Ground : Continuity should exist.
WIIA0602E
Page 888 of 3419

AUTOMATIC BACK DOOR SYSTEM
BL-121
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
Pinch Strip System InspectionEIS008RG
1. PINCH STRIP SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While operating the pinch strip, check voltage between back
door control unit connector B55 terminals 19, 20 and ground.
OK or NG
OK >> Pinch strip switch is OK.
NG >> GO TO 2.
2. PINCH STRIP CIRCUIT INSPECTION
1. Disconnect pinch strip and back door control unit.
2. Check continuity between pinch strip connector D715 (RH),
D517 (LH) terminal 1, 2 and back door control unit connector
B55 terminal 5, 19 (RH), 20 (LH).
OK or NG
OK >> GO TO 3.
NG >> Repair the harness between the pinch strip and the back
door control unit.
3. PINCH STRIP GROUND INSPECTION
1. Connect back door control unit connector.
2. Check continuity between pinch strip connector terminal 2 and
ground.
OK or NG
OK >> Replace the pinch strip.
NG >> Repair or replace harness.
Te r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
19
20GroundPinch strip operation 0
Other 4
LIIA0811E
1 - 19 : Continuity should exist.
1 - 20 : Continuity should exist.
2 - 5 : Continuity should exist.
LIIA0815E
2 - Ground : Continuity should exist.
LIIA0817E
Page 889 of 3419

BL-122
AUTOMATIC BACK DOOR SYSTEM
Revision: October 20052005 QX56
Back Door Warning Chime System InspectionEIS008RH
1. BACK DOOR WARNING CHIME CIRCUIT INSPECTION
1. Disconnect back door warning chime and back door control unit.
2. Check continuity between back door warning chime connector
D514 terminal 1 and back door control unit connector B55 termi-
nal 6.
OK or NG
OK >> GO TO 2.
NG >> Repair or replace harness.
2. WARNING CHIME CIRCUIT INSPECTION
Check continuity between back door warning chime connector D514
terminal 2 and back door control unit connector B55 terminal 9.
OK or NG
OK >> Replace warning chime.
NG >> Repair or replace harness.
Half-Latch Switch System InspectionEIS008RI
1. HALF-LATCH SWITCH SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While fully opening and closing the back door, check voltage
between back door control unit connector B55 terminal 22 and
ground.
OK or NG
OK >> Half-latch switch is OK.
NG >> GO TO 2.1 - 6 : Continuity should exist.
LIIA0822E
2 - 9 : Continuity should exist.
LIIA2182E
22 - Ground
LIIA0826EPIIA2169E
Page 890 of 3419

AUTOMATIC BACK DOOR SYSTEM
BL-123
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
2. HALF-LATCH SWITCH CIRCUIT INSPECTION
1. Disconnect back door latch and back door control unit connector.
2. Check continuity between back door latch (half-latch switch)
connector D503 terminal 6 and back door control unit connector
B55 terminal 22.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. HALF-LATCH SWITCH GROUND INSPECTION
Check continuity between back door latch (half-latch switch) connec-
tor D503 terminal 8 and ground.
OK or NG
OK >> Replace the back door latch.
NG >> Repair or replace harness.
Open Switch System InspectionEIS008RJ
1. OPEN SWITCH SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While fully closing and opening the back door, check voltage
between back door control unit connector B55 terminal 15 and
ground.
OK or NG
OK >> Open switch is OK.
NG >> GO TO 2.6 - 22 : Continuity should exist.
LIIA0827E
8 - Ground : Continuity should exist.
LIIA0828E
15 - Ground
LIIA0829EPIIA2171E
Page 891 of 3419
BL-124
AUTOMATIC BACK DOOR SYSTEM
Revision: October 20052005 QX56
2. OPEN SWITCH CIRCUIT INSPECTION
1. Disconnect back door latch and back door control unit connector.
2. Check continuity between back door latch (open switch) connec-
tor D503 terminal 4 and back door control unit connector B55
terminal 15.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. OPEN SWITCH GROUND INSPECTION
Check continuity between back door latch (open switch) connector
D503 terminal 8 and ground.
OK or NG
OK >> Replace the back door latch.
NG >> Repair or replace harness.
Close Switch System InspectionEIS008RK
1. CLOSE SWITCH SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While fully opening and closing the back door, check voltage
between back door control unit connector B55 terminal 14 and-
ground.
OK or NG
OK >> Close switch is OK.
NG >> GO TO 2.4 - 15 : Continuity should exist.
LIIA0830E
8 - Ground : Continuity should exist.
LIIA0828E
14 - Ground
LIIA0831EW IIA1047E
Page 892 of 3419

AUTOMATIC BACK DOOR SYSTEM
BL-125
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
2. CLOSE SWITCH CIRCUIT INSPECTION
1. Disconnect back door latch and back door control unit.
2. Check continuity between back door latch (close switch) con-
nector D503 terminal 5 and back door control unit connector
B55 terminal 14.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CLOSE SWITCH GROUND INSPECTION
Check continuity between back door latch (close switch) connector
D503 terminal 8 and ground.
OK or NG
OK >> Replace the back door latch.
NG >> Repair or replace harness.
Back Door Handle Switch System InspectionEIS008RL
1. BACK DOOR HANDLE SWITCH SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While operating the back door handle switch, check voltage
between back door control unit connector B55 terminal 26 and
ground.
OK or NG
OK >> Back door handle switch is OK.
NG >> GO TO 2.5 - 14 : Continuity should exist.
LIIA0832E
8 - Ground : Continuity should exist.
LIIA0828E
Te r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
26 GroundBack door handle switch (ON) 0
Other (OFF) Battery voltage
LIIA0833E
Page 893 of 3419

BL-126
AUTOMATIC BACK DOOR SYSTEM
Revision: October 20052005 QX56
2. BACK DOOR HANDLE SWITCH CIRCUIT INSPECTION
1. Disconnect back door handle switch and back door control unit.
2. Check continuity between back door handle switch connector
D706 terminal 3 and back door control unit connector B55 termi-
nal 26.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
3. BACK DOOR HANDLE SWITCH GROUND INSPECTION
Check continuity between back door handle switch connector D706
terminal 4 and ground.
OK or NG
OK >> Replace the back door handle switch.
NG >> Repair or replace harness.
Cinch Latch Motor System InspectionEIS008RM
1. CINCH LATCH MOTOR SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While fully opening and closing the back door, check voltage
between back door control unit connector B55 terminals 11, 12
and ground.
OK or NG
OK >> GO TO 2.
NG >> Replace the back door control unit.
2. CINCH LATCH MOTOR CIRCUIT INSPECTION
1. Disconnect back door latch and back door control unit.
2. Check continuity between back door latch (cinch latch motor)
connector D503 terminals 1, 2 and back door control unit con-
nector B55 terminals 11, 12.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.3 - 26 : Continuity should exist.
WIIA0604E
4 - Ground : Continuity should exist.
WIIA0605E
11 - Ground : Battery voltage.
12 - Ground : Battery voltage.
LIIA2397E
1 - 12 : Continuity should exist.
2 - 11 : Continuity should exist.
LIIA0837E