DTC P0222, P0223 TP SENSOR EC-281
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureABS006PP
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten ground three screws on the body. Refer to EC-170, "
Ground Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
TER-
MINAL NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
47 L Sensor power supply
(Throttle position sensor) [Ignition switch: ON]
Approximately 5V
50 W Throttle position sensor 1 [Ignition switch: ON]
Engine stopped
Selector lever: D
Accelerator pedal: Fully released
More than 0.36V
[Ignition switch: ON]
Engine stopped
Selector lever: D
Accelerator pedal: Fully depressed Less than 4.75V
66 B Sensor ground
(Throttle position sensor) [Engine is running]
Warm-up condition
Idle speed
Approximately 0V
69 R Throttle position sensor 2 [Ignition switch: ON]
Engine stopped
Selector lever: D
Accelerator pedal: Fully released
Less than 4.75V
[Ignition switch: ON]
Engine stopped
Selector lever: D
Accelerator pedal: Fully depressed More than 0.36V
91 G Sensor power supply
(APP sensor 2) [Ignition switch: ON]
Approximately 5V
PBIB2625E
EC-284
[VQ35DE]
DTC P0222, P0223 TP SENSOR
Revision: 2005 July 2005 FX
Component InspectionABS006PQ
THROTTLE POSITION SENSOR
1. Reconnect all harness connectors disconnected.
2. Perform EC-96, "
Throttle Valve Closed Position Learning" .
3. Turn ignition switch ON.
4. Set selector lever to D position.
5. Check voltage between ECM terminals 50 (TP sensor 1 signal), 69 (TP sensor 2 signal) and body ground under the following
conditions.
6. If NG, replace electric throttle control actuator and go to the next step.
7. Perform EC-96, "
Throttle Valve Closed Position Learning" .
8. Perform EC-97, "
Idle Air Volume Learning" .
Removal and InstallationABS006PR
ELECTRIC THROTTLE CONTROL ACTUATOR
Refer to EM-178, "INTAKE MANIFOLD" .
Terminal Accelerator pedal Voltage
50
(Throttle position sensor 1) Fully released More than 0.36V
Fully depressed Less than 4.75V
69
(Throttle position sensor 2) Fully released Less than 4.75V
Fully depressed More than 0.36V
PBIB1608E
DTC P0300 - P0306 MULTIPLE CYLINDER MISFIRE, NO. 1 - 6 CYLINDER MIS- FIRE
EC-285
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
DTC P0300 - P0306 MULTIPLE CYLINDER MISFIRE, NO. 1 - 6 CYLINDER MIS-
FIRE
PFP:00000
On Board Diagnosis LogicABS006PS
When a misfire occurs, engine speed will fluctuate. If the engine speed fluctuates enough to cause the crank-
shaft position (CKP) sensor (POS) signal to vary, ECM can determine that a misfire is occurring.
The misfire detection logic consists of the following two conditions.
1. One Trip Detection Logic (Three Way Catalyst Damage) On the 1st trip that a misfire condition occurs that can damage the three way catalyst (TWC) due to over-
heating, the MIL will blink.
When a misfire condition occurs, the ECM monitors the CKP sensor signal every 200 engine revolutions
for a change.
When the misfire condition decreases to a level that will not damage the TWC, the MIL will turn off.
If another misfire condition occurs that can damage the TWC on a second trip, the MIL will blink.
When the misfire condition decreases to a level that will not damage the TWC, the MIL will remain on.
If another misfire condition occurs that can damage the TWC, the MIL will begin to blink again.
2. Two Trip Detection Logic (Exhaust quality deterioration) For misfire conditions that will not damage the TWC (but will affect vehicle emissions), the MIL will only
light when the misfire is detected on a second trip. During this condition, the ECM monitors the CKP sen-
sor signal every 1,000 engine revolutions.
A misfire malfunction can be detected on any one cylinder or on multiple cylinders.
DTC Confirmation ProcedureABS0095P
CAUTION:
Always drive vehicle in safe manner according to traffic conditions and obey all traffic laws when driv-
ing.
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
Sensor Input Signal to ECM ECM function
Crankshaft position sensor (POS) Engine speed On board diagnosis of misfire
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0300
0300 Multiple cylinder misfire
detected Multiple cylinder misfire.
Improper spark plug
Insufficient compression
Incorrect fuel pressure
The injector circuit is open or shorted
Fuel injector
Intake air leak
The ignition signal circuit is open or
shorted
Lack of fuel
Signal plate
Air fuel ratio (A/F) sensor 1
Incorrect PCV hose connection
P0301
0301 No.1 cylinder misfire
detected No. 1 cylinder misfires.
P0302
0302 No. 2 cylinder misfire
detected No. 2 cylinder misfires.
P0303
0303 No. 3 cylinder misfire
detected No. 3 cylinder misfires.
P0304
0304 No. 4 cylinder misfire
detected No. 4 cylinder misfires.
P0305
0305 No. 5 cylinder misfire
detected No. 5 cylinder misfires.
P0306
0306 No. 6 cylinder misfire
detected No. 6 cylinder misfires.
EC-286
[VQ35DE]
DTC P0300 - P0306 MULTIPLE CYLINDER MISFIRE, NO. 1 - 6 CYLINDER MIS- FIRE
Revision: 2005 July 2005 FX
WITH CONSULT-II
1. Turn ignition switch ON, and select “DATA MONITOR” mode
with CONSULT-II.
2. Start engine and warm it up to normal operating temperature.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Restart engine and let it idle for about 15 minutes.
5. If 1st trip DTC is detected, go to EC-286, "
Diagnostic Procedure"
.
NOTE:
If 1st trip DTC is not detected during above procedure, performing
the following procedure is advised.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Start engine and drive the vehicle under the similar conditions to (1st trip) Freeze Frame Data for a certain time. Refer to table below.
Hold the accelerator pedal as steady as possible.
The similar conditions to (1st trip) Freeze Frame Data means the vehicle operation that the following condi-
tions should be satisfied at the same time.
The time to driving varies according to the engine speed in the freeze frame data.
Refer to the following table.
WITH GST
Follow the procedure “WITH CONSULT-II” above.
Diagnostic ProcedureABS006PU
1. CHECK FOR INTAKE AIR LEAK AND PCV HOSE
1. Start engine and run it at idle speed.
2. Listen for the sound of the intake air leak.
3. Check PCV hose connection.
OK or NG
OK >> GO TO 2.
NG >> Discover air leak location and repair.
2. CHECK FOR EXHAUST SYSTEM CLOGGING
Stop engine and visually check exhaust tube, three way catalyst and muffler for dents.
OK or NG
OK (With CONSULT-II)>>GO TO 3.
OK (Without CONSULT-II)>>GO TO 4.
NG >> Repair or replace it.
PBIB0164E
Engine speed Engine speed in the freeze frame data ± 400 rpm
Vehicle speed Vehicle speed in the freeze frame data ± 10 km/h (6 MPH)
Engine coolant temperature
(T) condition When the freeze frame data shows lower than 70
°C (158 °F),
T should be lower than 70 °C (158 °F).
When the freeze frame data shows higher than or equal to 70 °C (158 °F),
T should be higher than or equal to 70 °C (158 °F).
Engine speed Time
Around 1,000 rpm Approximately 10 minutes
Around 2,000 rpm Approximately 5 minutes
More than 3,000 rpm Approximately 3.5 minutes
DTC P0327, P0328 KS EC-297
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureABS006PZ
1. CHECK KNOCK SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT-I
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check resistance between ECM terminal 15 and ground. Refer to Wiring Diagram. NOTE:
It is necessary to use an ohmmeter which can measure more than 10 M Ω.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> GO TO 2.
2. CHECK KNOCK SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT-II
1. Disconnect knock sensor harness connector.
2. Check harness continuity between ECM terminal 15 and knock sensor terminal 1.
Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
3. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F20, F252
Harness for open or short between ECM and knock sensor
>> Repair open circuit or short to ground or short to power in harness or connectors.
4. CHECK KNOCK SENSOR
Refer to EC-298, "
Component Inspection" .
OK or NG
OK >> GO TO 5.
NG >> Replace knock sensor.
TER-
MINAL NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
15 W Knock sensor [Engine is running]
Idle speedApproximately 2.5V
Resistance: Approximately 532 - 588 k
Ω [at 20 °C (68 °F)]
Continuity should exist.
PBIB1564E
DTC P0335 CKP SENSOR (POS) EC-303
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnostic ProcedureABS006Q7
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten ground three screws on the body. Refer to EC-170, "
Ground Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
TER-
MINAL
NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
13 Y Crankshaft position sensor
(POS) [Engine is running]
Warm-up condition
Idle speed
NOTE:
The pulse cycle changes depending on rpm
at idle Approximately 1.6V
[Engine is running]
Engine speed is 2,000 rpm Approximately 1.4V
PBIB1041E
PBIB1042E
PBIB2625E
EC-312
[VQ35DE]
DTC P0340, P0345 CMP SENSOR (PHASE)
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnostic ProcedureABS006QE
1. CHECK STARTING SYSTEM
Turn ignition switch to START position.
Ye s o r N o
Yes >> GO TO 2.
No >> Check starting system. (Refer to SC-10, "
STARTING SYSTEM" .)
2. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten ground three screws on the body. Refer to EC-170, "
Ground Inspection" .
OK or NG
OK >> GO TO 3.
NG >> Repair or replace ground connections.
TER-
MINAL
NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
14 BR Camshaft position sensor
(PHASE) (bank 2) [Engine is running]
Warm-up condition
Idle speed
NOTE:
The pulse cycle changes depending on rpm
at idle 1.0 - 4.0V
[Engine is running]
Engine speed is 2,000 rpm 1.0 - 4.0V
PBIB1039E
PBIB1040E
Does the engine turn over?
Does the starter motor operate?
PBIB2625E
EC-316
[VQ35DE]
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
Revision: 2005 July 2005 FX
DTC P0420, P0430 THREE WAY CATALYST FUNCTIONPFP:20905
On Board Diagnosis LogicABS006QH
The ECM monitors the switching frequency ratio of air fuel ratio (A/F) sensor 1 and heated oxygen sensor 2.
A three way catalyst 1 with high oxygen storage capacity will indicate a low switching frequency of heated oxy-
gen sensor 2. As oxygen storage capacity decreases, the heated oxygen sensor 2 switching frequency will
increase.
When the frequency ratio of air fuel ratio (A/F) sensor 1 and heated oxygen sensor 2 approaches a specified
limit value, the three way catalyst 1 malfunction is diagnosed.
DTC Confirmation ProcedureABS006QI
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
WITH CONSULT-II
TESTING CONDITION:
Do not hold engine speed for more than the specified minutes below.
1. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-II.
2. Start engine and warm it up to the normal operating tempera- ture.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
5. Let engine idle for 1 minute.
6. Make sure that “COOLAN TEMP/S” indicates more than 70 °C
(158 °F).
If not, warm up engine and go to next step when “COOLAN
TEMP/S” indication reaches to 70 °C (158 °F).
7. Open engine hood.
PBIB1923E
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0420
0420
(Bank 1)
Catalyst system effi-
ciency below threshold
Three way catalyst 1 does not operate prop-
erly.
Three way catalyst 1 does not have enough
oxygen storage capacity.
Three way catalyst 1
Exhaust tube
Intake air leaks
Fuel injector
Fuel injector leaks
Spark plug
Improper ignition timing
P0430
0430
(Bank 2)
SEF189Y