ISUZU TF SERIES 2004  Workshop Manual 6D3-2  STARTING AND CHARGING SYSTEM 
 
 
 Starting System 
General Description 
Cranking Circuit 
The cranking system consists of a battery, starter, starter 
switch, starter relay, etc. These main co

Page 2557 of 4264

ISUZU TF SERIES 2004  Workshop Manual STARTING AND CHARGING SYSTEM  6D3-3 
 
   
Starter 
Removal 
1.  Remove the battery ground cable. 
2.  Remove harness connectors (1) and (2). 
 
 
 
 
3.  Remove bolts from starter. 
 
 
 
Installatio

Page 2560 of 4264

ISUZU TF SERIES 2004  Workshop Manual 6D3-6  STARTING AND CHARGING SYSTEM 
 
  
 
 Continuity of Contacts 
With the plunger faced downward, push down the magnetic 
switch. In this state, check for continuity between terminals B 
and M. Re

Page 2562 of 4264

ISUZU TF SERIES 2004  Workshop Manual 6D3-8  STARTING AND CHARGING SYSTEM 
 
 General On-Vehicle Inspection 
The operating condition of charging system is indicated by the 
charge warning lamp. The warning lamp comes on when the 
starter

Page 2563 of 4264

ISUZU TF SERIES 2004  Workshop Manual STARTING AND CHARGING SYSTEM  6D3-9 
 
  
 
 Generator Power 
1.  Adjust load resistor, if the required load currents are not 
attained. 
2. The shape of the voltage curves on oscilloscope curve
shoul

Page 2564 of 4264

ISUZU TF SERIES 2004  Workshop Manual 6D3-10  STARTING AND CHARGING SYSTEM 
  The generator has four external connections; the "B+" lead to 
battery positive, "L" lead to the warning lamp circuit(max. 2 
watts), "S" lead to battery positi

Page 2565 of 4264

ISUZU TF SERIES 2004  Workshop Manual STARTING AND CHARGING SYSTEM  6D3-11 
 Warning  
Do not reverse S and L connections as this will destroy the 
warning lamp circuit of the regulator. 
Ensure good electrical contact beween generator  e

Page 2566 of 4264

ISUZU TF SERIES 2004  Workshop Manual 6D3-12  STARTING AND CHARGING SYSTEM 
  Diagnosis 
The EP regulator incorporates diagnostics which will illuminate 
the warning lamp as a result of fault conditions in the generator 
and external circ