2004 INFINITI QX56 battery

[x] Cancel search: battery

Page 293 of 3371

INFINITI QX56 2004  Factory Service Manual AT-222
TROUBLE DIAGNOSIS FOR SYMPTOMS
Revision: August 20072004 QX56
2. CHECK 4TH POSITION SWITCH CIRCUIT
 With CONSULT-II
1. Turn ignition switch “ON”.
2. Select "ECU INPUT SIGNALS" in "DATA MONI

Page 299 of 3371

INFINITI QX56 2004  Factory Service Manual AT-228
TROUBLE DIAGNOSIS FOR SYMPTOMS
Revision: August 20072004 QX56
2. CHECK 1ST POSITION SWITCH CIRCUIT
 With CONSULT-II
1. Turn ignition switch “ON”.
2. Select "ECU INPUT SIGNALS" in "DATA MONI

Page 301 of 3371

INFINITI QX56 2004  Factory Service Manual AT-230
TROUBLE DIAGNOSIS FOR SYMPTOMS
Revision: August 20072004 QX56
9. DETECT MALFUNCTIONING ITEM
Check the malfunction items. If any items are damaged, repair or replace damaged parts. Refer to AT-

Page 309 of 3371

INFINITI QX56 2004  Factory Service Manual AT-238
A/T SHIFT LOCK SYSTEM
Revision: August 20072004 QX56
Shift Lock Control Unit Reference ValuesUCS002J 9
SHIFT LOCK HARNESS CONNECTOR TERMINALS LAYOUT
SHIFT LOCK CONTROL UNIT INSPECTION TABLE
Dat

Page 310 of 3371

INFINITI QX56 2004  Factory Service Manual A/T SHIFT LOCK SYSTEM
AT-239
D
E
F
G
H
I
J
K
L
MA
B
AT
Revision: August 20072004 QX56
Component InspectionUCS002J A
SHIFT LOCK SOLENOID
Check operation by applying battery voltage to the A/T device.

Page 311 of 3371

INFINITI QX56 2004  Factory Service Manual AT-240
A/T SHIFT LOCK SYSTEM
Revision: August 20072004 QX56
Key unlock
Check operation by applying battery voltage to key switch and
key lock solenoid.
CAUTION:
Be careful not to cause burnout of the

Page 313 of 3371

INFINITI QX56 2004  Factory Service Manual AT-242
ON-VEHICLE SERVICE
Revision: August 20072004 QX56
CONTROL VALVE WITH TCM REMOVAL AND INSTALLATION
Removal
1. Disconnect negative battery terminal
2. Drain ATF through drain plug.
3. Disconnect

Page 319 of 3371

INFINITI QX56 2004  Factory Service Manual AT-248
ON-VEHICLE SERVICE
Revision: August 20072004 QX56
b. Install oil pan (with oil pan gasket) to transmission case.
CAUTION:
Install it so that drain plug comes to the position as
shown in the fi
Page:   < prev 1-8 9-16 17-24 25-32 33-40 41-48 49-56 ... 528 next >