LT-80
TURN SIGNAL AND HAZARD WARNING LAMPS
Revision: August 20072004 QX56
TURN SIGNAL AND HAZARD WARNING LAMPSPFP:26120
Component Parts and Harness Connector LocationEKS007BI
System DescriptionEKS007BJ
OUTLINE
Power is supplied at all times
through 50A fusible link (letter f , located in the fuse and fusible link box)
to BCM (body control module) terminal 70, and
through 10A fuse [No. 19, located in the fuse block (J/B)]
to combination meter terminal 8.
TURN SIGNAL OPERATION
When the ignition switch is in the ON or START position, power is supplied
through 10A fuse (No. 59, located in the fuse and relay box)
to BCM terminal 38, and
through 10A fuse [No. 14, located in the fuse block (J/B)]
to combination meter terminal 24.
Ground is supplied
to BCM terminal 67 and
to combination meter terminal 17
through grounds M57, M61 and M79.
LH Turn
When the turn signal switch is moved to the left position, the BCM, interpreting it as turn signal is ON, outputs
turn signal from BCM terminal 60.
The BCM supplies power
through BCM terminal 60
to front turn/fog lamp LH terminal 2
WKIA3396E
TURN SIGNAL AND HAZARD WARNING LAMPS
LT-81
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: August 20072004 QX56
through front turn/fog lamp LH terminal 3
to grounds E9, E15 and E24, and
to rear turn signal lamp LH terminal 1
through rear turn signal lamp LH terminal 3
to grounds B7 and B19.
BCM sends signal to combination meter through CAN communication lines, and turns on turn signal indicator
lamp within combination meter.
RH Turn
When the turn signal switch is moved to the right position, the BCM, interpreting it as turn signal is ON, outputs
turn signal from BCM terminal 61.
The BCM supplies power
through BCM terminal 61
to front turn/fog lamp RH terminal 2
through front turn/fog lamp RH terminal 3
to grounds E9, E15 and E24, and
to rear turn signal lamp RH terminal 1
through rear signal lamp terminal 3
to grounds B117 and B132.
BCM sends signal to combination meter through CAN communication lines, and turns on turn signal indicator
lamp within combination meter.
HAZARD LAMP OPERATION
Power is supplied at all times
through 50A fusible link (letter f , located in the fuse and fusible link box)
to BCM terminal 70, and
through 10A fuse [No. 19, located in the fuse block (J/B)]
to combination meter terminal 8.
Ground is supplied
to BCM terminal 67 and
to combination meter terminal 17
to grounds M57, M61 and M79.
When the hazard switch is depressed, ground is supplied
to BCM terminal 29
through hazard switch terminal 2
through hazard switch terminal 1
through grounds M57, M61 and M79.
When the hazard switch is depressed, the BCM, interpreting it as turn signal is ON, outputs turn signal from
BCM terminals 60 and 61.
The BCM supplies power
through BCM terminals 60 and 61
to front turn/fog lamp LH and RH terminal 2
through front turn/fog lamp LH and RH terminal 3
to grounds E9, E15 and E24, and
to rear turn signal lamp LH terminal 1
through rear turn signal lamp LH terminal 3
to grounds B7 and B19, and
to rear turn signal lamp RH terminal 1
through rear turn signal lamp terminal 3
to grounds B117 and B132.
BCM sends signal to combination meter through CAN communication lines, and turns on turn signal indicator
lamps within combination meter.
LT-82
TURN SIGNAL AND HAZARD WARNING LAMPS
Revision: August 20072004 QX56
REMOTE KEYLESS ENTRY SYSTEM OPERATION
Power is supplied at all times
through 50A fusible link (letter f , located in the fuse and fusible link box)
to BCM terminal 70, and
through 10A fuse [No. 19, located in the fuse block (J/B)]
to combination meter terminal 8.
Ground is supplied
to BCM terminal 67 and
to combination meter terminal 17
through grounds M57, M61 and M79.
When the remote keyless entry system is triggered by input from the keyfob, the BCM, interpreting it as turn
signal is ON, output turn signal from BCM terminals 60 and 61.
The BCM supplies power
through BCM terminals 60 and 61
to front turn/fog lamp LH and RH terminal 2
through front turn/fog lamp LH and RH terminal 3
to grounds E9, E15 and E24, and
to rear turn signal lamp LH terminal 1
through rear turn signal lamp LH terminal 3
to grounds B7 and B19, and
to rear turn signal lamp RH terminal 1
through rear turn signal lamp RH terminal 3
to grounds B117 and B132.
BCM sends signal to combination meter through CAN communication lines, and turns on turn signal indicator
lamps within combination meter.
With power and input supplied, the BCM controls the flashing of the hazard warning lamps when keyfob is
used to activate the remote keyless entry system.
COMBINATION SWITCH READING FUNCTION
Refer to BCS-3, "COMBINATION SWITCH READING FUNCTION" .
CAN Communication System DescriptionEKS007BK
Refer to LAN-5, "CAN COMMUNICATION" .
TURN SIGNAL AND HAZARD WARNING LAMPS
LT-93
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: August 20072004 QX56
3. CHECK HAZARD SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connector and hazard switch connector.
3. Check continuity between BCM harness connector M18 terminal
29 (W/B) and hazard switch harness connector M55 terminal 2
(W/B).
OK or NG
OK >> GO TO 4.
NG >> Repair harness or connector.
4. CHECK GROUND
Check continuity between hazard switch harness connector M55 ter-
minal 1 (B) and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair harness or connector.
5. CHECK HAZARD SWITCH
1. Disconnect hazard switch connector.
2. Check continuity of hazard switch.
OK or NG
OK >> Replace BCM if turn signal lamps does not work after
setting the connector again. Refer to BCS-19, "
Removal
and Installation of BCM" .
NG >> Replace hazard switch. Refer to LT-96, "
Removal and Installation" .
Turn Signal Indicator Lamp Does Not OperateEKS007BT
1. CHECK CAN COMMUNICATION SYSTEM
Check CAN communication. Refer to LAN-5, "
CAN COMMUNICATION" .
OK or NG
OK >> Replace combination meter. Refer to IP-13, "Combination Meter" .
NG >> Repair as necessary.29 (W/B) - 2 (W/B) : Continuity should exist.
WKIA1894E
1 (B) - Ground : Continuity should exist.
WKIA1895E
Hazard switch
Condition Continuity
Te r m i n a l
12Hazard switch is ON Yes
Hazard switch is OFF No
WKIA1896E
LT-152
ILLUMINATION
Revision: August 20072004 QX56
ILLUMINATIONPFP:27545
Component Parts and Harness Connector LocationEKS007D9
System DescriptionEKS007DA
Control of the illumination lamps operation is dependent upon the position of the lighting switch (combination
switch). When the lighting switch is placed in the 1ST or 2ND position (or if the auto light system is activated)
the BCM (body control module) receives input signal requesting the illumination lamps to illuminate. This input
signal is communicated to the IPDM E/R (intelligent power distribution module engine room) across the CAN
communication lines. The CPU (central processing unit) of the IPDM E/R controls the tail lamp relay coil. This
relay, when energized, directs power to the illumination lamps, which then illuminate.
Power is supplied at all times
to tail lamp relay, located in the IPDM E/R, and
through 50A fusible link (letter f , located in the fuse and fusible link box)
to BCM terminal 70, and
through 20A fuse (No. 53, located in the IPDM E/R)
to CPU of the IPDM E/R, and
through 10A fuse [No.19, located in fuse block (J/B)]
to combination meter terminal 8, and
WKIA3399E
ILLUMINATION
LT-153
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: August 20072004 QX56
to ignition relay, located in the IPDM E/R.
With the ignition switch in the ON or START position, power is supplied
through 10A fuse (No. 59, located in the fuse and relay box)
to BCM terminal 38, and
to ignition relay in the IPDM E/R, and
through 10A fuse [No. 14, located in the fuse block (J/B)]
to combination meter terminal 24.
Ground is supplied
to BCM terminal 67 and
to combination meter terminal 17
through grounds M57, M61 and M79, and
to IPDM E/R terminals 38 and 59
through grounds E9, E15 and E24.
ILLUMINATION OPERATION BY LIGHTING SWITCH
With the lighting switch in the 1ST or 2ND position (or if the auto light system is activated), the BCM receives
input signal requesting the illumination lamps to illuminate. This input signal is communicated to the IPDM E/R
across the CAN communication lines. The CPU of the IPDM E/R controls the tail lamp relay coil, which, when
energized, directs power
through 10A fuse (No. 36, located in the IPDM E/R)
through IPDM E/R terminal 49
to illumination control switch terminal 1
to power liftgate switch terminal 3
to front room/map lamp assembly (console box illumination) terminal 7
to hazard switch terminal 3
to rear sonar system OFF switch terminal 3
to glove box lamp terminal +
to display control unit terminal 14
to 4WD shift switch terminal 7 (with 4-wheel drive)
to front air control terminal 23
to rear power vent window switch terminal 5
to DVD player terminal 12 (with DVD entertainment system)
to NAVI control unit terminal 25
to pedal adjusting switch terminal 5
to electric brake (pre-wiring) terminal 4
to heated seat switches terminal 5
to A/T device terminal 11
to VDC OFF switch terminal 3
to tow mode switch terminal 3
to headlamp aiming switch terminal 3
to clock terminal 3
to compass and thermometer terminal 4, and
through 10A fuse (No. 37, located in the IPDM E/R)
through IPDM E/R terminal 57
to AV switch terminal 3
to audio unit terminal 8
to rear air control terminal 1 and
to rear audio remote control unit terminal 6.
Illumination is controlled
through illumination control switch terminal 2
LT-154
ILLUMINATION
Revision: August 20072004 QX56
to power liftgate switch terminal 4
to front room/map lamp assembly (console box illumination) terminal 8
to AV switch terminal 4
to hazard switch terminal 4
to audio unit terminal 7
to rear sonar system OFF switch terminal 4
to 4WD switch terminal 8 (with 4-wheel drive)
to front air control terminal 24 and
to rear power vent window switch terminal 6
to DVD player terminal 10 (with DVD entertainment system)
to pedal adjusting switch terminal 6
to A/T device terminal 12
to front heated seat switches terminal 6
to VDC OFF switch terminal 4
to tow mode switch terminal 4
to headlamp aiming switch terminal 4
to clock terminal 4 and
to combination meter terminal 18.
Ground is supplied
to illumination control switch terminal 3
to glove box lamp terminal –
to display control unit terminal 3
to rear heated seat switches terminal 6
to electric brake (pre-wiring) terminal 1 and
to compass and thermometer terminal 7
through grounds M57, M61 and M79, and
to NAVI control unit terminal 30
to rear air control terminal 3 and
to rear audio remote control unit terminal 15
through grounds B117 and B132.
With power and ground supplied, illumination lamps illuminate.
EXTERIOR LAMP BATTERY SAVER CONTROL
When the combination switch (lighting switch) is in the 1ST or 2ND position (or if auto light system is acti-
vated), and the ignition switch is turned from ON or ACC to OFF, the battery saver control function is activated.
Under this condition, the illumination lamps remain illuminated for 5 minutes, then the illumination lamps are
turned off.
When the lighting switch is turned from OFF to 1ST or 2ND position (or if auto light system is activated) after
illumination lamps are turned off by the battery saver control, the illumination lamps illuminate again.
Exterior lamp battery saver control mode can be changed by the function setting of CONSULT-II.
CAN Communication System DescriptionEKS007DB
Refer to LAN-5, "CAN COMMUNICATION" .
ILLUMINATION
LT-169
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: August 20072004 QX56
Removal and InstallationEKS007DE
ILLUMINATION CONTROL SWITCH
1. Remove cluster lid A. Refer to DI-25, "Removal and Installation of Combination Meter" .
2. Carefully pry tabs and remove illumination control switch from
cluster lid A.
Installation is in the reverse order of removal.
WKIA1403E