2004 INFINITI FX35 ground

[x] Cancel search: ground

Page 1645 of 4449

INFINITI FX35 2004  Service Manual EC-304
[VQ35DE]
DTC P0335 CKP SENSOR (POS)
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by

Page 1646 of 4449

INFINITI FX35 2004  Service Manual DTC P0335 CKP SENSOR (POS)
EC-305
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
2. CHECK CRANKSHAFT POSITION (CKP) SENSOR (POS) POWER SUPPLY CIRCUIT
1. Disconnect crankshaf

Page 1647 of 4449

INFINITI FX35 2004  Service Manual EC-306
[VQ35DE]
DTC P0335 CKP SENSOR (POS)
Revision: 2004 November 2004 FX35/FX45
6. CHECK CKP SENSOR (POS) INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.
2. Check harnes

Page 1651 of 4449

INFINITI FX35 2004  Service Manual EC-310
[VQ35DE]
DTC P0340, P0345 CMP SENSOR (PHASE)
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is me

Page 1653 of 4449

INFINITI FX35 2004  Service Manual EC-312
[VQ35DE]
DTC P0340, P0345 CMP SENSOR (PHASE)
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is me

Page 1654 of 4449

INFINITI FX35 2004  Service Manual DTC P0340, P0345 CMP SENSOR (PHASE)
EC-313
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
3. CHECK CAMSHAFT POSITION (CMP) SENSOR (PHASE) POWER SUPPLY CIRCUIT
1. Disconnect

Page 1655 of 4449

INFINITI FX35 2004  Service Manual EC-314
[VQ35DE]
DTC P0340, P0345 CMP SENSOR (PHASE)
Revision: 2004 November 2004 FX35/FX45
7. CHECK CMP SENSOR (PHASE) INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.
2. C

Page 1658 of 4449

INFINITI FX35 2004  Service Manual DTC P0420, P0430 THREE WAY CATALYST FUNCTION
EC-317
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
8. Select “DTC & SRT CONFIRMATION” then “SRT WORK SUP-
PORT” mode