Page 168 of 933
19 - 8
19
COOLIN G - EX HA U ST - FU EL TANK
COOLING FAN DIAGNOSTIC
for vehicles with air conditioning
vnx.su
Page 169 of 933
19 - 9
19
COOLING - EXHA U ST - FUEL TANK
RESISTANCE COOLING FAN REPLACEMENT
for vehicles with air conditioning
De scription of t he opera tion :
Di sconnect the battery (-) term inal.
Di sconnect the resistance connector.
Di smount the two attachment screws of the re sistance.
Position the new resistance assembly.
Mount the two attachment screws of the resistance (tightening moment 4.5 Nm).
Connect the resistance connector.
Connect t he battery (-) terminal. In case the vehicle is equipped with programmable
radio-cassettes player, electronic clock, etc, those are to be re-programmed before return-
ing the vehicle to the client. Check the engine motor fa n operation.
vnx.su
Page 170 of 933

19 - 10
19
COOLING - EX HA U ST - FU EL TANK
COOLING FAN REPLACEMENT
for vehicles without air conditioning
6 5
4 3 7
1
2
DISMOUNTING
Di
sconnect the (-) plug of the battery.
Di sconnect the cooling fan connector (7).
Dismount the three-attachement screws (6) of the cooling fan on the radiator, recovering the
attachement buffers (2), cross-pieces (3) and the washers (4) and (5).
Remove the cooling fan assembly (1).
REMOUNTING
Check the condition of the fan propeller, cooling fan electric motor, bushings and washers.
Tighten the attachement screw (6) of the assembly.
Connect the cooling fan connector (7).
Connect the battery pl ug (-). In case the vehicle is equipped with progammable radio-
cassettes, electronic clock, etc, these are t o be reset before re turning t he vehicle to the
client.
Check the cooling fan opera tion: start the ve hicle e ngine and disconnect t he water tem-
perature sensor. The cooling fan must start. Reconnect the water tempera ture sensor, then
by means of the CLIP tester, erase the memori zed failure related to the water t empera ture
sensor.
FAILURES
ERASING
vnx.su
Page 171 of 933
19 - 11
19
COOLIN G - EX HA U ST - FU EL TANK
COOLING FAN DIAGNOSTIC
for vehicles without air conditioning
vnx.su
Page 389 of 933

Mechanisms and accesoires5
Climatisation6
Garnishing and tack room7
Electr ic equipment8
57 LOWER INTERNAL ACCESSORIESDashboard..................................................... 57-1
Dashboard upper part ................................... 57-3
Central console............................................. 56-4
Documents compartment.............................. 57-5
Ste ering whee l axle hal f-cases...................... 57-6
Inside rear view mirror.................................. 57-7
S un visors...................................................... 57-8
Turning handles............................................ 57-9
Handbrake case............................................. 57-10
59 SAFETY ELEMENTS Front safety belts........................................... 59-1
Re ar safety belts............................................ 59-2
61 HEATING Climat e control asse mbly.............................. 61-1
Housing manifold.......................................... 61-2
Heating radiator............................................. 61-3
C limat e control blower.................................. 61-4
Diagnosis....................................................... 61-5
62 AIR CONDITIONING Generalities.................................................. 62-1
AC unit operating diagram........................... 62-4
Evaporator.................................................... 62-5
Comp ressor................................................... 62-7
Condenser..................................................... 62-8
Pr essure controller........................................ 62-9
Dryer filter tank............................................ 62-10
Unit piping.................................................... 62-11
C limat e control unit...................................... 62-12
Diagnosis....................................................... 62-13
65 SEALING OPENING ELEMENTS Carriage body se aling................................... 65-1
66 SEALING WINDOWS AND SCREENS Glasses sealing............................................. 66-1
Insi de wipers ............................................... 66-2
Outside wipers.............................................. 66-3
71 INTERNAL BODY TRIM Carriage body coverings.............................. 71-1
Fr ont door threshold covering...................... 71-2
Upper front pillar covering........................... 71-3
Re ar door threshold covering....................... 71-4
Mi ddle pillar covering.................................. 71-5
Re ar passa ge covering.................................. 71-6
Re ar wheel passage covering........................ 71-7
Mi ddle pillar lower covering........................ 71-8
Re ar side panel covering............................... 71-9
R oof gasket .................................................... 71-10 Carpets
......................................................... 71-11
Cowl panel noise absorbent ......................... 71-12
72 SIDE OPENING ELEMENTS TRIM Front door panel........................................... 72-1
Re ar door panel............................................ 72-2
74 BACK SEAT TABLES AND PARCEL SHELVES Upper back panel replacement...................... 74-1
75 FRONT SEATS FRAMES AND RUNNERS Front seats.................................................... 75-1
Fr ont seat slides guides................................ 75-2
Fr ont seat armature...................................... 75-3
76 REAR SEATS FRAMES AND RUNNERS Rear bench................................................... 76-1
B ench seats .................................................. 76-2
77 FRONT SEAT TRIM Seats upholstery dismounting...................... 77-1
Back rest upholstery dismounting................ 77-2
78 REAR SEAT TRIM Seats upholstery dismounting...................... 78-1
Back rest upholstery dismounting................ 78-2
80 BATTERY - FRONT HEADLIGHTS Battery... ...................................................... 80-1
Head lamp asse mb ly..................................... 80-4
F og lamps.................................................... 80-5
Bulbs r eplacement....................................... 80-6
Headlamps adjustment................................. 80-7
81 REAR AND INTERIOR LIGHTING Bulbs r eplacement........................................ 81-1
Bulbs ............................................................ 81-2
Diagnostic.................................................... 81-3
Cockpit fuse box.......................................... 81-6
82A HORN - ENGINE IMMOBILISER Gene ralities.................................................. 82A-1
Key head repla ceme nt.................................. 82A-6
E.C.U. decoder repla ceme nt........................ 82A-7
Antistarting bushing replaceme nt................ 82A-8
RF remote control for blocking/unlocking
t he doors...................................................... 82A-9
Electric control unit injection repla cement... 82A-10
Pr ocedures.................................................... 82A-11
Diagnostic..................................................... 82A-17
vnx.su
Page 407 of 933
HEATING
61
61 - 5
CLI
MATE CONTROL BLOWER DOES NOT WORKING
Check fuse F 01.
F01 good. Check F09.
F09 good. Check blower supply.
F01 blown. Replace the fuse.
The blower is not supplied.
Check R2 relay. The blower is supplied.
Check the air conditioning switch.
Relay R2 is damaged.
Replace the relay.The relay is not da
maged.
Broken or disconnected
relay switch wiring. Good switch.
Ma
ss wire
disconnected or brok en.Damaged switch.
Replace the switch.
DIAGNOSIS
vnx.su
Page 408 of 933

AIR CONDITIONING
62
62 - 1
GENERALITIES
GENERALITIES
The purpose of the a ir conditioning unit i s to produce a decrease of t he temperature in the
passengers compartment a nd to obtain a l ower value t emperature compared to the external
environment one, reducing in the same time the air moisture.
MAINTENANCE
For a vehicle equipped with air conditioning, it is recommended a frequent checking of the
refrigerating agent level. During the year it is recommended:
- the checking of the refrigerant fluid filling;
- the cleaning and the air-blowing of the condenser and the cooling radiator fins;
- the checking of the condensation removal pipe on order not to be clogged.
For important leakage repair, for any components replacement (compressor, condenser, etc)
and if moisture was noticed in t he air conditioning circuit, the dryer filter tank is to be replaced
and the unit draining is to be performed. The same is valid also in case the conditioning circuit
remains open without protection covers more than 10 minutes.
IMP ORTANT
Duri ng winter, it is recommended the frequent start of the system, in order to pro-
long the lifetime of the compressor and of the whole system.
The vehicle equipped with an air conditioning system shall be not exposed for more
than 20 minutes i n painting c abin where there are temperatures higher than 80 °C.
It is obligatory the use of the refrigerating agent and compressor oil type prescribed
by the manufacturer. It is absolutely forbidden to perform welding on the elements of the air condition
circ uits. The filling of the air conditioning system can be pe rformed only by m eans of charging
units and observing the instructions of the manufacturer. For mechanical or body
operations it is recommended pi ping protection in order to avoid their disconnection
by accident. Avoid the drip of the oil compressor on the painted vehicle body.
For component replacement implying the circuit draining, it is absolutely necessary
the use of new parts and of a special oil for compressor.
vnx.su
Page 409 of 933

AIR CONDITIONING
62
62 - 2
AIR COND
ITIONING UNIT
DISMOUNTING
Make the unit functioning for at least 10 minutes (if the unit permits).
Drain the circuit at the filling equipment.
Measure the quantity of recovered refrigerated fluid.
Release the access to the component that is needed to be changed.
Disconnect the connections.
In order to avoid the moisture infiltration, protect with protection covers.
Dismount the component.
REMOUNTING
P ut special c ompressor oil on the new elements thread and on the gaskets.
AT TENT ION
The new components must be obligatory provided with protection c overs.
Remove t he protection covers, connect the new component on t he free connection,
and tighten it by hand.
Place the component correctly.
Tighten it at couple.
Refill with refrigerant fluid and oil.
The filling up with oil for different repairs is to be performed as follows: add in the charging
equipment container, the recovered oil quantity, plus an oil quantity, as it follows:
- sudden damaged of one of the unit’s element or leakage 100ml
- condenser replacement 30 ml
- evaporator replacement 30 ml
- dryer filter replacement 15 ml
- pipe replacement 10 ml
For compressor dismounting/remounting without replacement add 120 ml.
If there are signs of moisture in the air conditioning circuit, replace the dryer filter tank.
62
GENERALITIES
!
vnx.su