Page 1305 of 2234
550YQ±01
I35277
Blower Assy
Air Duct No.2
Recirculation Damper Servo Sub±assy
Air FilterAir Filter Case
Blower w/ fan Motor Sub±assy
Manual A/C: Blower Resistor
Air Conditioning Wire No.1
Auto A/C:
Blower Motor Control
9.8 (100, 87 in. lbf)
Cooler Wiring No.1Manual A/C:
N
m (kgf cm, ftlbf): Specified torque
55±64
±
HEATER & AIR CONDITIONER BLOWER ASSY
AVENSIS REPAIR MANUAL (RM1018E)
BLOWER ASSY
COMPONENTS
http://vnx.su
Page 1307 of 2234
I353162 Claws
I35318
I35319Clamp
I35320
55±66
±
HEATER & AIR CONDITIONER BLOWER ASSY
AVENSIS REPAIR MANUAL (RM1018E)
5. REMOVE AIR FILTER CASE
(a) Release the 2 claw fittings and remove the air filter case.
6. REMOVE AIR FILTER 7. REMOVE RECIRCULATION DAMPER SERVOSUB±ASSY
(a) Remove the 2 screws and the recirculation damper servo sub±assy.
8. REMOVE AIR CONDITIONING WIRENO1 (MANUAL AIR CONDITIONING)
(a) Disconnect the connector.
(b) Release the clump and remove the air conditioning wire No.1.
9. REMOVE COOLER WIRING NO.1 (AUTO AIR CONDITIONING)
HINT:
Disconnection of the cooler wiring No.1 is the same as the air condition\
ing wire No.1. 10. REMOVE BLOWER RESISTOR (MANUAL AIRCONDITIONING)
(a) Remove the 2 screws and the blower resistor.
http://vnx.su
Page 1308 of 2234
I35321
I35322
I35317
I36813
I35314
±
HEATER & AIR CONDITIONER BLOWER ASSY
55±67
AVENSIS REPAIR MANUAL (RM1018E)
11. REMOVE BLOWER MOTOR CONTROL (AUTO AIR
CONDITIONING)
(a) Remove the 2 screws and the blower motor control.
12. REMOVE BLOWER W/FAN MOTOR SUB±ASSY
(a) Remove the 3 screws and the blower w/ fun motor sub±
assy.
13. INSTALL AIR FILTER
(a) Install the air filter as shown in the illustration.
14. INSTALL BLOWER ASSY
(a) Install the blower assy with the claw fitting.
(b) Install the blower assy with the 2 bolts and the 2 screws. Torque: 9.8 N m (100 kgfcm, 87 in.lbf) (Bolt)
(c) Install the 2 nuts.
(d) Connect the connectors.
http://vnx.su
Page 1321 of 2234
550YS±01
I35345Claw
I35346
I35347
I35348
55±100
±
HEATER & AIR CONDITIONER HEATER ASSY
AVENSIS REPAIR MANUAL (RM1018E)
HEATER ASSY
REPLACEMENT
1.REMOVE AIR CLEANER ASSY (See page 11±82)
2.REMOVE FUEL FILTER ASSY (See page 11±82) 3. REMOVE AIR DUCT NO.3
(a) Release the claw fitting and remove the bolt and the en-gine room relay No.2 block.
(b) Remove the clip and the air duct No.3.
4. DISCONNECT HEATER INLET WATER HOSE
(a) Using pliers, grip the claws of the clip and slide the clip to disconnect the heater inlet water hose.
HINT:
Prepare a support plate and waste to catch the leaked coolant.
5. DISCONNECT HEATER WATER INLET HOSE A
(a) Using pliers, grip the claws of the clip and slide the clip to disconnect the heater inlet water hose A.
HINT:
Prepare a support plate and waste to catch the leaked coolant.
http://vnx.su
Page 1322 of 2234
I35349
I35350
I35350
I35349
±
HEATER & AIR CONDITIONER HEATER ASSY
55±101
AVENSIS REPAIR MANUAL (RM1018E)
6. REMOVE HEATER ASSY
(a) Using pliers, grip the claws of the clip and slide the clip to
disconnect the heater fuel hose.
HINT:
Prepare a support plate and waste to catch the leaked fuel.
(b) Disconnect the connector.
(c) Remove the 2 bolts and the heater assy.
7. INSTALL HEATER ASSY
(a) Install the heater assy with the 2 bolts. Torque: 7.5 N m (76 kgf cm, 66 in. lbf)
(b) Connect the connector.
(c) Install the heater fuel hose.
HINT:
Prepare a support plate and waste to catch the leaked fuel.
8.INSTALL FUEL FILTER ASSY (See page 11±82)
9.INSTALL AIR CLEANER ASSY (See page 11±82)
10.ADD ENGINE COOLANT (See page 16±44)
11.CHECK FOR ENGINE COOLANT LEAKS (See page 16±37)
12.CHECK FUEL LEAK (See page 11±56)
http://vnx.su
Page 1334 of 2234
E65563
I22117
Condition: Air conditioning system periodically repeats proper and improper functi\
on.
±
HEATER & AIR CONDITIONER REFRIGERANT
55±33
AVENSIS REPAIR MANUAL (RM1018E)
(1) When the refrigerant volume is proper:
Gauge reading:
Low pressure side:
0.28 ± 0.4 MPa (2.8 ± 4.0 kgf/cm
2)
High pressure side:
1.3 ± 1.6 MPa (13 ± 16 kgf/cm
2)
(2) When there is moisture in the refrigeration system:
SymptomProbable causeDiagnosisRemedy
During operation, pressure on low
pressure side cycles between nor-
mal and vacuum
Moisture in refrigeration system
freezes at refrigerant filter orifice,
causing a temporary stop of cycle.
However, when it melts, normal
state is restored Drier is overly saturated
Moisture in refrigeration system
freezes at refrigerant filter orifice
and blocks circulation of refriger-
ant(1) Replace cooler drier
(2) Remove moisture in cycle by
repeatedly vacuuming
(3) Supply proper amount of new
refrigerant
http://vnx.su
Page 1336 of 2234

I22120
Condition: Air conditioning system does not function. (Sometimes it may function)\
I22121
Condition : Air conditioning system does not function effectively.
±
HEATER & AIR CONDITIONER REFRIGERANT
55±35
AVENSIS REPAIR MANUAL (RM1018E)
(5) When the refrigerant does not circulate:
SymptomProbable causeDiagnosisCorrective Actions
Vacuum is indicated on low pres-
sure side, and extreamly low pres-
sure is indicated on high pressure
side
Frost or dew is seen on piping on
both sides of condenser or refrig-
erant filter
Refrigerant flow is obstructed by
moisture or dirt in refrigeration sys-
tem
Refrigerant filter is clogged
Refrigerant does not circulate
(1) Check the refrigerant filter
(2) Clean out dirt on refrigerant fil-
ter by blowing air
(3) Replace condenser
(4) Vacuum air and supply proper
amount of new refrigerant
(5) If refrigerant filter is damaged,
replace it
(6) When the refrigerant is overcharged or cooling of
condenser is insufficient:
SymptomProbable causeDiagnosisRemedy
Pressure is extreamly high on
both low and high pressure sides Excessive refrigerant
Cooling performance of con-
denser is insufficient Excessive refrigerant
Cooling performance of con-
denser is insufficient
Magnet valve assy is defective
(1) Clean condenser fins
(2) Check condenser fan motor
operation
(3) If (1) and (2) are in normal
state, vacuum and supply proper
amount of refrigerant
(4) If pressure is still high even af-
ter supplying refrigerant, replace
the magnet valve assy
http://vnx.su
Page 1337 of 2234
I22122
ConditionNOTE : These gauge indica-
tions occur when the refrigera-
tion system opens and the re-
frigerant is charged without
vacuuming.
: Air conditioning system does not function.
I22123
Condition : Air conditioning system does not function effectively.
55±36
±
HEATER & AIR CONDITIONER REFRIGERANT
AVENSIS REPAIR MANUAL (RM1018E)
(7) When there is air in the refrigeration system:
SymptomProbable causeDiagnosisCorrective Actions
Pressure is extreamly high on both
low and the high pressure sidesAir in refrigeration system
There is air in refrigeration sys-
tem
Vacuuming is insufficient(1) Check if compressor oil is dirty
or insufficient
(2) Vacuum air and supply new re-
frigerant
(8) When the refrigerant filter is defective:
SymptomProbable causeDiagnosisCorrective Actions
Pressure is extreamly high on
low pressure side
Pressure is extreamly high on
high pressure side
Trouble with refrigerant filterExcessive refrigerantReplace refrigerant filter
http://vnx.su