2003 NISSAN TEANA Engine

[x] Cancel search: Engine

Page 1968 of 3502

NISSAN TEANA 2003  Service Manual EC-686
[VQ]
FUEL INJECTOR
 
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals

Page 1969 of 3502

NISSAN TEANA 2003  Service Manual FUEL INJECTOR
EC-687
[VQ]
C
D
E
F
G
H
I
J
K
L
MA
EC
 
3. CHECK FUNCTION OF FUEL INJECTOR-I
 Without CONSULT-II
1. Stop engine.
2. Disconnect harness connector F1, F251.
3. Turn ignition switch ON.
4.

Page 1970 of 3502

NISSAN TEANA 2003  Service Manual EC-688
[VQ]
FUEL INJECTOR
 
6. CHECK FUNCTION OF FUEL INJECTOR-III
1. Reconnect all harness connector disconnected.
2. Start engine.
3. Listen to fuel injectors No. 2, No. 4, No.6 operating sound.
OK

Page 1972 of 3502

NISSAN TEANA 2003  Service Manual EC-690
[VQ]
FUEL PUMP
 
FUEL PUMPPFP:17042
DescriptionBBS0056P
SYSTEM DESCRIPTION
*: ECM determines the start signal status by the signals of engine speed and battery voltage.
The ECM activates the fu

Page 1974 of 3502

NISSAN TEANA 2003  Service Manual EC-692
[VQ]
FUEL PUMP
 
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing s

Page 1977 of 3502

NISSAN TEANA 2003  Service Manual FUEL PUMP
EC-695
[VQ]
C
D
E
F
G
H
I
J
K
L
MA
EC
 
12. CHECK FUEL PUMP
Refer to EC-695, "
Component Inspection" .
OK or NG
OK >> GO TO 13.
NG >> Replace fuel pump.
13. CHECK INTERMITTENT INCIDENT
Refer

Page 1978 of 3502

NISSAN TEANA 2003  Service Manual EC-696
[VQ]
HO2S1
 
HO2S1PFP:22690
Component DescriptionBBS0055O
The heated oxygen sensor 1 is placed into the exhaust manifold. It
detects the amount of oxygen in the exhaust gas compared to the
outs

Page 1980 of 3502

NISSAN TEANA 2003  Service Manual EC-698
[VQ]
HO2S1
 
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when mea