Fig. 58: Removing Air Outlet Servomotor
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
26.REMOVE WIRING AIR CONDITIONING HARNESS SUB-ASSY
27.INSTALL COOLER EXPANSION VALVE
a. Sufficiently apply compressor oil to 4 new O-rings and fitting surface of the cooler expansion
valve.
Compressor oil: ND-OIL 8 or equivalent
b. Install the 4 O-rings to the cooler expansion valve.
c. Using a hexagon wrench 5 mm (0.20 in.), install the cooler expansion valve with the 2 hexagon
bolts.
Torque: 4.1 N.m (42 kgf.cm, 36 ft.lbf)
Fig. 128: Removing Rear Cooling Unit Expansion Valve
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
36.INSTALL REAR COOLING UNIT EXPANSION VALVE
a. Sufficiently apply compressor oil to 4 new O-rings and fitting surface of the cooler expansion
valve.
Compressor oil: ND-OIL 8 or equivalent
b. Install the 4 O-rings on the rear cooling unit expansion valve.
c. Using a hexagon wrench 5 mm (0.20 in.), install the rear cooling unit expansion valve, air
conditioning tube assy with the 2 hexagon bolts.
Torque: 3.5 N.m (36 kgf.cm, 31 in.lbf)