INSPECTION
1. REMOVE AMBIENT TEMPERATURE SENSOR
(a) Disconnect the connector.
(b) Pull out the sensor.
2. INSPECT AMBIENT TEMPERATURE SENSOR
(See page DI±2322)
3. INSTALL AMBIENT TEMPERATURE SENSOR
Page 3827 of 4323

I21455
2
13
4
AC1LS±03
Z13470
Low pressure High pressure
side side
ON (Continuity)
3,140 kpa 196 kpa
(2.0 kgf/cm
2, 28psi)
OFF (No Continuity)(32.0 kgf/cm2, 455psi)
OFF (No Continuity)
I05079
ON (Continuity)
1,520 kpa
1,230 kpa
(12.5 kgf/cm
2, 178psi) OFF (No Continuity)
(15.5 kgf/cm
2, 220psi) Cooling Fan Control AC±92
± AIR CONDITIONINGPRESSURE SWITCH
3819 Author: Date:
2005 SEQUOIA (RM1146U)
PRESSURE SWITCH
ON±VEHICLE INSPECTION
1. SET MANIFOLD GAUGE SET (See page AC±18)
2. DISCONNECT CONNECTOR
3. RUN ENGINE AT APPROX. 2,000 rpm
4. SET BLOWER SPEED CONTROL SWITCH TO ºHIº
POSITION
5. SET TEMPERATURE CONTROL LEVER TO ºMAX.
COOLº POSITION
6. A/C SWITCH ON
7. INSPECT PRESSURE SWITCH OPERATION
(a) Connect the positive (+) lead from the ohmmeter to termi-
nal 4 and the negative (±) lead to terminal 1.
(b) Check continuity between terminals when refrigerant
pressure is changed, as shown in the illustration.
If operation is not as specified, replace the pressure switch.
8. Cooling fan control:
INSPECT PRESSURE SWITCH OPERATION
9. STOP ENGINE AND REMOVE MANIFOLD GAUGE
SET
10. CONNECT CONNECTOR TO PRESSURE SWITCH
(a) Connect the positive (+) lead from the ohmmeter to termi-
nal 2 and the negative (±) lead to terminal 3.
(b) Check continuity between terminals when refrigerant
pressure is changed, as shown in the illustration.
If operation is not as specified, replace the pressure switch.
11. STOP ENGINE AND REMOVE MANIFOLD GAUGE
SET
12. CONNECT CONNECTOR TO PRESSURE SWITCH
Page 3829 of 4323
AC1LU±01
AC±94
± AIR CONDITIONINGPRESSURE SWITCH
3821 Author: Date:
2005 SEQUOIA (RM1146U)
INSTALLATION
Installation is in the reverse order of removal (See page AC±93).
Page 3835 of 4323
AC1M3±01
AC±100
± AIR CONDITIONINGCONDENSER FAN
3827 Author: Date:
2005 SEQUOIA (RM1146U)
REASSEMBLY
Reassembly is in the reverse order of disassembly (See page AC±99).
Page 3836 of 4323
AC1M4±02
± AIR CONDITIONINGCONDENSER FAN
AC±101
3828 Author: Date:
2005 SEQUOIA (RM1146U)
INSTALLATION
Installation is in the reverse order of removal (See page AC±98).
Page 3842 of 4323
AC3HZ±01
± AIR CONDITIONINGAIR CONDITIONER CONTROL ASSEMBLY (Center
Cluster Integration)AC±107
3834 Author: Date:
2005 SEQUOIA (RM1146U)
REASSEMBLY
Reassembly is in the reverse order of disassembly (See page AC±111).
Page 3843 of 4323
AC3I0±01
AC±108± AIR CONDITIONINGAIR CONDITIONER CONTROL ASSEMBLY (Center
Cluster Integration)
3835 Author: Date:
2005 SEQUOIA (RM1146U)
INSTALLATION
Installation is in the reverse order of removal (See page AC±110).
Page 3848 of 4323
AC3I6±01
± AIR CONDITIONINGREAR A/C CONTROL ASSEMBLY (for Rear A/C)
AC±113
3840 Author: Date:
2005 SEQUOIA (RM1146U)
REASSEMBLY