Diagnostic ProcedureECS004RS
1.CHECK VALVE RESISTANCE
1. Turn ignition switch to “OFF” position.
2. Dis NISSAN X-TRAIL 2001 Service Repair Manual DTC P0740 TORQUE CONVERTER CLUTCH SOLENOID VALVE
AT-161
[EURO-OBD]
D
E
F
G
H
I
J
K
L
MA
B
AT
Diagnostic ProcedureECS004RS
1.CHECK VALVE RESISTANCE
1. Turn ignition switch to “OFF” position.
2. Dis](/manual-img/5/57405/w960_57405-2238.png)
DTC P0740 TORQUE CONVERTER CLUTCH SOLENOID VALVE
AT-161
[EURO-OBD]
D
E
F
G
H
I
J
K
L
MA
B
AT
Diagnostic ProcedureECS004RS
1.CHECK VALVE RESISTANCE
1. Turn ignition switch to “OFF” position.
2. Disconnect terminal cord assembly connector in engine compartment.
3. Check resistance between terminal 5 and ground.
OK or NG
OK >> GO TO 2.
NG >> 1. Remove oil pan. Refer to AT- 4 1 4 , "
ON-VEHICLE
SERVICE" .
2. Check the following items:
–Torque converter clutch solenoid valve
Refer to AT- 1 6 2 , "
Component Inspection" .
–Harness of terminal cord assembly for short or open
2.CHECK POWER SOURCE CIRCUIT
1. Turn ignition switch to “OFF” position.
2. Disconnect TCM harness connector.
3. Check continuity between terminal 5 and TCM harness connector terminal 3.
If OK, check harness for short to ground and short to power.
4. Reinstall any part removed.
OK or NG
OK >> GO TO 3.
NG >> Repair open circuit or short to ground or short to power
in harness or connectors.
3.CHECK DTC
Perform Diagnostic Trouble Code (DTC) confirmation procedure. Refer to AT- 1 5 9 , "
DIAGNOSTIC TROUBLE
CODE (DTC) CONFIRMATION PROCEDURE" .
OK or NG
OK >>INSPECTION END
NG >> 1. Perform TCM input/output signal inspection.
2. If NG, recheck TCM pin terminals for damage or loose connection with harness connector. Resistance: 5 - 20Ω
SCIA0731E
Continuity should exist.
SCIA0732E
Page 2240 of 3833
AT-162
[EURO-OBD]
DTC P0740 TORQUE CONVERTER CLUTCH SOLENOID VALVE
Component Inspection
ECS004RT
TORQUE CONVERTER CLUTCH SOLENOID VALVE
●For removal, refer to AT-414, "REMOVAL" .
Resistance Check
●Check resistance between two terminals.
Operation Check
●Check solenoid valve by listening for its operating sound while
applying battery voltage to the terminal and ground.
SCIA0733E
Solenoid valve Terminal No.Resistance
(Approx.)
Torque converter
clutch solenoid
valve5 Ground 5 - 20Ω
SCIA0734E
Page 2263 of 3833
![NISSAN X-TRAIL 2001 Service Repair Manual DTC P1760 OVERRUN CLUTCH SOLENOID VALVE
AT-185
[EURO-OBD]
D
E
F
G
H
I
J
K
L
MA
B
AT
DTC P1760 OVERRUN CLUTCH SOLENOID VALVEPFP:31940
DescriptionECS004S9
The overrun clutch solenoid valve is acti NISSAN X-TRAIL 2001 Service Repair Manual DTC P1760 OVERRUN CLUTCH SOLENOID VALVE
AT-185
[EURO-OBD]
D
E
F
G
H
I
J
K
L
MA
B
AT
DTC P1760 OVERRUN CLUTCH SOLENOID VALVEPFP:31940
DescriptionECS004S9
The overrun clutch solenoid valve is acti](/manual-img/5/57405/w960_57405-2262.png)
DTC P1760 OVERRUN CLUTCH SOLENOID VALVE
AT-185
[EURO-OBD]
D
E
F
G
H
I
J
K
L
MA
B
AT
DTC P1760 OVERRUN CLUTCH SOLENOID VALVEPFP:31940
DescriptionECS004S9
The overrun clutch solenoid valve is activated by the TCM in
response to signals sent from the inhibitor switch, overdrive control
switch, vehicle speed and throttle position sensors. The overrun
clutch operation will then be controlled.
TCM TERMINALS AND REFERENCE VALUE
Remarks: Specification data are reference values.
ON BOARD DIAGNOSIS LOGIC
SCIA0718E
Te r m i -
nal No.Wire color Item ConditionJudgement stan-
dard
(Approx.)
20 L/BOverrun clutch
solenoid valveWhen overrun clutch solenoid valve
operates.Battery voltage
When overrun clutch solenoid valve
does not operate.0V
Diagnostic trouble code Malfunction is detected when... Check items (Possible cause)
: O/R CLTCH SOL/CIRC
TCM detects an improper voltage drop
when it tries to operate the solenoid valve.
●Harness or connectors
(The solenoid circuit is open or shorted.)
●Overrun clutch solenoid valve
: P1760
Page 2264 of 3833
AT-186
[EURO-OBD]
DTC P1760 OVERRUN CLUTCH SOLENOID VALVE
DIAGNOSTIC TROUBLE CODE (DTC) CONFIRMATION PROCEDURE
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If “DIAGNOSTIC TROUBLE CODE CONFIRMATION PROCE-
DURE” has been previously conducted, always turn ignition
switch “OFF” and wait at least 5 seconds before conducting the
next test.
TESTING CONDITION:
Always drive vehicle on a level road to improve accuracy of
test.
After the repair, perform the following procedure to confirm the mal-
function is eliminated.
With CONSULT-II
1. Turn ignition switch “ON” and select “DATA MONITOR” mode for
“ENGINE” with CONSULT-II.
2. Start engine.
3. Accelerate vehicle to a speed of more than 10 km/h (6 MPH)
with “D” position (OD “ON”).
4. Release accelerator pedal completely with “D” position (OD “OFF”).
With GST
Follow the procedure “With CONSULT-II”.
SAT014K
SAT020K
Page 2265 of 3833
DTC P1760 OVERRUN CLUTCH SOLENOID VALVE
AT-187
[EURO-OBD]
D
E
F
G
H
I
J
K
L
MA
B
AT
Wiring Diagram — AT — OVRCSVECS004SA
TCWA0042E
Page 2266 of 3833
![NISSAN X-TRAIL 2001 Service Repair Manual AT-188
[EURO-OBD]
DTC P1760 OVERRUN CLUTCH SOLENOID VALVE
Diagnostic Procedure
ECS004SB
1. CHECK VALVE RESISTANCE
1. Turn ignition switch to “OFF” position.
2. Disconnect terminal cord assembly co NISSAN X-TRAIL 2001 Service Repair Manual AT-188
[EURO-OBD]
DTC P1760 OVERRUN CLUTCH SOLENOID VALVE
Diagnostic Procedure
ECS004SB
1. CHECK VALVE RESISTANCE
1. Turn ignition switch to “OFF” position.
2. Disconnect terminal cord assembly co](/manual-img/5/57405/w960_57405-2265.png)
AT-188
[EURO-OBD]
DTC P1760 OVERRUN CLUTCH SOLENOID VALVE
Diagnostic Procedure
ECS004SB
1. CHECK VALVE RESISTANCE
1. Turn ignition switch to “OFF” position.
2. Disconnect terminal cord assembly connector in engine compartment.
3. Check resistance between terminal 3 and ground.
OK or NG
OK >> GO TO 2.
NG >> 1. Remove control valve assembly. Refer to AT- 4 1 4 ,
"REMOVAL" .
2. Check the following items:
–Overrun clutch solenoid valve
Refer to AT-189, "
Component Inspection" .
–Harness of terminal cord assembly for short or open
2. CHECK POWER SOURCE CIRCUIT
1. Turn ignition switch to “OFF” position.
2. Disconnect TCM harness connector.
3. Check continuity between terminal 3 and TCM harness connector terminal 20.
If OK, check harness for short to ground and short to power.
4. Reinstall any part removed.
OK or NG
OK >> GO TO 3.
NG >> Repair open circuit or short to ground or short to power
in harness or connectors.
3. CHECK DTC
Perform Diagnostic Trouble Code (DTC) confirmation procedure. Refer to AT- 1 8 6 , "
DIAGNOSTIC TROUBLE
CODE (DTC) CONFIRMATION PROCEDURE" .
OK or NG
OK >>INSPECTION END
NG >> 1. Perform TCM input/output signal inspection.
2. If NG, recheck TCM pin terminals for damage or loose connection with harness connector. Resistance: 20 - 30Ω
SCIA0727E
Continuity should exist.
SCIA0728E
Page 2267 of 3833
DTC P1760 OVERRUN CLUTCH SOLENOID VALVE
AT-189
[EURO-OBD]
D
E
F
G
H
I
J
K
L
MA
B
AT
Component InspectionECS004SC
OVERRUN CLUTCH SOLENOID VALVE
●For removal, refer to AT-414, "REMOVAL" .
Resistance Check
●Check resistance between two terminals.
Operation Check
●Check solenoid valve by listening for its operating sound while
applying battery voltage to the terminal and ground.
SCIA0729E
Solenoid valve Terminal No.Resistance
(Approx.)
Overrun clutch
solenoid valve3 Ground 20 - 30Ω
SCIA0730E
Page 2291 of 3833
TROUBLE DIAGNOSES FOR SYMPTOMS
AT-213
[EURO-OBD]
D
E
F
G
H
I
J
K
L
MA
B
AT
In “N” Position, Vehicle MovesECS004SX
SYMPTOM:
Vehicle moves forward or backward when selecting “N” position.
1.CHECK CONTROL CABLE
Check control cable. Refer to AT-416, "
Control Cable Adjustment" .
OK or NG
OK >> GO TO 2.
NG >> Adjust control cable. Refer to AT- 4 1 6 , "
Control Cable
Adjustment" .
2.CHECK A/T FLUID LEVEL
Check A/T fluid level again.
OK or NG
OK >> GO TO 3.
NG >> Refill ATF.
3.CHECK A/T FLUID CONDITION
1. Remove oil pan.
2. Check A/T fluid condition.
OK or NG
OK >> GO TO 4.
NG >> 1. Disassemble A/T.
2. Check the following items:
–Forward clutch assembly
–Overrun clutch assembly
–Reverse clutch assembly
4.CHECK SYMPTOM
Check again.
OK or NG
OK >>INSPECTION END
NG >> 1. Perform TCM input/output signal inspection.
2. If NG, recheck TCM pin terminals for damage or loose connection with harness connector.
SAT023JB