Page 1660 of 2898

System Description/HatchbackNJEL0430TURN SIGNAL OPERATIONNJEL0430S01Power is supplied at all times
+through 30A fusible link (letter E, located in fuse and fusible link box)
+to circuit breaker terminal 1
+through circuit breaker terminal 2
+to time control unit terminal 8, and
+through 15A fuse [No. 5, located in fuse block (J/B)]
+to time control unit terminal 9
With the ignition switch in the ON or START position, power is supplied
+through 10A fuse [No. 10, located in fuse block (J/B)]
+to time control unit terminal 1
Ground is supplied to time control unit terminal 16 through body grounds M28 and M67.
LH TurnNJEL0430S0101When the turn signal switch is moved to the L position, ground is supplied from body grounds E30 and E73
to
+time control unit terminal 2
+through turn signal switch terminal 3
With ground is supplied, time control unit controls the flashing of the LH turn signal lamps.
RH TurnNJEL0430S0102When the turn signal switch is moved to the R position, ground is supplied from body grounds E30 and E73
to
+time control unit terminal 4
+through turn signal switch terminal 2
With ground is supplied, time control unit controls the flashing of the RH turn signal lamps.
HAZARD LAMP OPERATIONNJEL0430S02Power is supplied at all times
+through 30A fusible link (letter E, located in fuse and fusible link box)
+to circuit breaker terminal 1
+through circuit breaker 2
+to time control unit terminal 8
+through 15A fuse [No. 5, located in fuse block (J/B)]
+to time control unit terminal 9
Ground is supplied to time control unit terminal 16 through body grounds M28 and M67.
With the hazard switch in the ON position, ground is supplied from body grounds M28 and M67 to
+time control unit terminal 5
+through hazard switch terminal 3
With ground is supplied, time control unit controls the flashing of the hazard warning lamps.
HAZARD REMINDER OPERATION FOR MULTI-REMOTE CONTROL SYSTEMNJEL0430S04When the doors are locked or unlocked by multi-remote controller, time control unit controls turn lamps haz-
ard reminder flashes as follows.
+Locked operation: Flash once
+Unlock operation: Flash twice
TURN SIGNAL AND HAZARD WARNING LAMPS
System Description/Hatchback
EL-102
Page 1673 of 2898
![NISSAN ALMERA 2001 Service Manual System Description/Sedan With Interior Room
Lamp Timer
=NJEL0366POWER SUPPLY AND GROUNDNJEL0366S01Power is supplied at all times:
+through 10A fuse [No. 12, located in the fuse block (J/B)]
+to key sw NISSAN ALMERA 2001 Service Manual System Description/Sedan With Interior Room
Lamp Timer
=NJEL0366POWER SUPPLY AND GROUNDNJEL0366S01Power is supplied at all times:
+through 10A fuse [No. 12, located in the fuse block (J/B)]
+to key sw](/manual-img/5/57348/w960_57348-1672.png)
System Description/Sedan With Interior Room
Lamp Timer
=NJEL0366POWER SUPPLY AND GROUNDNJEL0366S01Power is supplied at all times:
+through 10A fuse [No. 12, located in the fuse block (J/B)]
+to key switch terminal 1 and
+to time control unit terminal 1
+through 10A fuse [No. 13, located in the fuse block (J/B)]
+to interior room lamp terminal 1.
When the key is removed from ignition key cylinder, power is interrupted:
+through key switch terminal 2
+to time control unit terminal 18.
With the ignition key switch in the ON or START position, power is supplied:
+through 10A fuse [No. 10, located in the fuse block (J/B)]
+to time control unit terminal 17.
Ground is supplied:
+through body grounds terminals M28 and M67
+to time control unit terminal 16
When the driver side door is opened, ground is supplied:
+through body grounds B9, B21 and B308
+to door switch driver side terminal 3
+from door switch driver side terminal 2
+to time control unit terminal 30.
When any door is opened, ground is supplied:
+through case ground of each door switch
+to each door switch terminal 1
+to time control unit terminal 31.
When the driver side door is unlocked, the time control unit receives a ground signal:
+through body grounds terminals M28 and M67
+to door unlock sensor terminal 2
+from door unlock sensor terminal 5
+to time control unit terminal 28.
When a signal, or combination of signals is received by the time control unit, ground is supplied:
+through time control unit terminal 26
+to interior room lamp terminal 2.
With power and ground supplied, the interior room lamp illuminates.
SWITCH OPERATIONNJEL0366S02When interior room lamp switch is ON, ground is supplied:
+through case grounds of interior room lamp
+to interior room lamp.
INTERIOR ROOM LAMP TIMER OPERATIONNJEL0366S03When interior room lamp switch is in the ªDOORº position, the time control unit keeps the interior room lamp
illuminated for about 30 seconds when:
+unlock signal is supplied from driver's door unlock sensor or multi-remote controller while all doors are
closed and key is out of ignition key cylinder
+key is removed from ignition key cylinder while all doors are closed
+driver's door is opened and then closed while key is out of the iginition key cylinder. (However, if the driv-
er's door is closed with the key inserted in the ignition key cylinder after the driver's door is opened with
the key removed, the timer is operated.)
The timer is canceled when:
+driver's door is locked,
INTERIOR ROOM LAMP
System Description/Sedan With Interior Room Lamp Timer
EL-115
Page 1677 of 2898
Trouble Diagnoses/Sedan With Interior Room
Lamp Timer
=NJEL0368DIAGNOSTIC PROCEDURE 1NJEL0368S01SYMPTOM: Interior room lamp timer does not operate.
1 CHECK IGNITION ON SIGNAL
Check voltage between time control unit harness connector terminal 17 and ground.
SEL985W
OK or NG
OK©GO TO 2.
NG©Check the following.
+10A fuse [No. 10, located in fuse block (J/B)]
+Harness for open or short between time control unit and fuse
2 CHECK DOOR SWITCH INPUT SIGNAL
Check voltage between time control unit harness connector terminal 30 and ground.
SEL986W
OK or NG
OK©GO TO 4.
NG©GO TO 3.
INTERIOR ROOM LAMP
Trouble Diagnoses/Sedan With Interior Room Lamp Timer
EL-119
Page 1681 of 2898
9 CHECK KEY SWITCH (INSERT)
Check continuity between terminals 1 and 2.
SEL922W
OK or NG
OK©Check the following.
+10A fuse [No. 12, located in fuse block (J/B)]
+Harness for open or short between key switch and fuse
+Harness for open or short between time control unit and key switch
NG©Replace key switch.
INTERIOR ROOM LAMP
Trouble Diagnoses/Sedan With Interior Room Lamp Timer (Cont'd)
EL-123
Page 1682 of 2898
DIAGNOSTIC PROCEDURE 2=NJEL0368S02SYMPTOM: Interior lamp timer does not cancel properly.
1 CHECK IGNITION ON SIGNAL
Check voltage between time control unit harness connector terminal 17 and ground.
SEL985W
OK or NG
OK©GO TO 2.
NG©Check the following.
+10A fuse [No. 10, located in fuse block (J/B)]
+Harness for open or short between time control unit and fuse
2 CHECK DOOR SWITCH INPUT SIGNAL
Check voltage between time control unit harness connector terminal 30 and ground.
SEL986W
OK or NG
OK©GO TO 4.
NG©GO TO 3.
INTERIOR ROOM LAMP
Trouble Diagnoses/Sedan With Interior Room Lamp Timer (Cont'd)
EL-124
Page 1685 of 2898
![NISSAN ALMERA 2001 Service Manual System Description/Hatchback With Interior
Room Lamp Timer
=NJEL0435POWER SUPPLY AND GROUNDNJEL0435S01Power is supplied at all times:
+through 15A fuse [No. 5, located in the fuse block (J/B)]
+to tim NISSAN ALMERA 2001 Service Manual System Description/Hatchback With Interior
Room Lamp Timer
=NJEL0435POWER SUPPLY AND GROUNDNJEL0435S01Power is supplied at all times:
+through 15A fuse [No. 5, located in the fuse block (J/B)]
+to tim](/manual-img/5/57348/w960_57348-1684.png)
System Description/Hatchback With Interior
Room Lamp Timer
=NJEL0435POWER SUPPLY AND GROUNDNJEL0435S01Power is supplied at all times:
+through 15A fuse [No. 5, located in the fuse block (J/B)]
+to time control unit terminal 9,
+through 10A fuse [No. 12, located in the fuse block (J/B)]
+to key switch terminal 1 and
+through 10A fuse [No. 13, located in the fuse block (J/B)]
+to interior room lamp terminal 1.
When the key is removed from ignition key cylinder, power is interrupted:
+through key switch terminal 2
+to time control unit terminal 22.
With the ignition key switch in the ON or START position, power is supplied:
+through 10A fuse [No. 10, located in the fuse block (J/B)]
+to time control unit terminal 1.
Ground is supplied:
+through body grounds terminals M28 and M67
+to time control unit terminal 16
When the driver side door is opened, ground is supplied:
+through body grounds B9, B21 and D96
+to door switch driver side terminal 3
+from door switch driver side terminal 2
+to time control unit terminal 6.
When any door is opened, ground is supplied:
+through case ground of each door switch
+to each door switch terminal 1
+to time control unit terminal 7.
When the driver side door is unlocked, the time control unit receives a ground signal:
+through body grounds terminals M28 and M67
+to door unlock sensor terminal 2
+from door unlock sensor terminal 5
+to time control unit terminal 35.
When a signal, or combination of signals is received by the time control unit, ground is supplied:
+through time control unit terminal 12
+to interior room lamp terminal 2.
With power and ground supplied, the interior room lamp illuminates when interior room lamp switch is in
ªDOORº position.
SWITCH OPERATIONNJEL0435S02When interior room lamp switch is in ªONº position, ground is supplied:
+through case grounds of interior room lamp
+to interior room lamp.
With power and ground supplied, the interior room lamp illuminates.
INTERIOR ROOM LAMP TIMER OPERATIONNJEL0435S03When interior room lamp switch is in the ªDOORº position, the time control unit keeps the interior room lamp
illuminated for about 30 seconds when:
+unlock signal is supplied from driver's door unlock sensor while all doors are closed
+key is removed from ignition key cylinder while all doors are closed
+driver's door is opened and then closed
The timer is canceled when:
INTERIOR ROOM LAMP
System Description/Hatchback With Interior Room Lamp Timer
EL-127
Page 1689 of 2898
Trouble Diagnoses/Hatchback With Interior
Room Lamp Timer
=NJEL0437DIAGNOSTIC PROCEDURE 1NJEL0437S01SYMPTOM: Interior room lamp timer does not operate.
1 CHECK IGNITION ON SIGNAL
Check voltage between time control unit harness connector terminal 1 and ground.
SEL429X
OK or NG
OK©GO TO 2.
NG©Check the following.
+10A fuse [No. 10, located in fuse block (J/B)]
+Harness for open or short between time control unit and fuse
2 CHECK DOOR SWITCH INPUT SIGNAL
Check voltage between time control unit harness connector terminal 6 and ground.
SEL430X
OK or NG
OK©GO TO 4.
NG©GO TO 3.
INTERIOR ROOM LAMP
Trouble Diagnoses/Hatchback With Interior Room Lamp Timer
EL-131
Page 1693 of 2898
9 CHECK KEY SWITCH (INSERT)
Check continuity between terminals 1 and 2.
YEL786C
OK or NG
OK©Check the following.
+10A fuse [No. 12, located in fuse block (J/B)]
+Harness for open or short between key switch and fuse
+Harness for open or short between time control unit and key switch
NG©Replace key switch.
INTERIOR ROOM LAMP
Trouble Diagnoses/Hatchback With Interior Room Lamp Timer (Cont'd)
EL-135