COLORITEM CONDITION DATA (DC Voltage)
62 G/BHeated oxygen sensor
1 (front) (bank 2)[Engine is running]
IWarm-up condition
IEngine speed is 2,000 rpm.0 - Approximately 1.0V (Peri-
odically change)
SEF059V
SEF237U
On Board Diagnosis LogicNBEC0089Under the condition in which the heated oxygen sensor 1 (front)
signal is not input, the ECM circuits will read a continuous approxi-
mately 0.3V. Therefore, for this diagnosis, the time that output
voltage is within 200 to 400 mV range is monitored, and the diag-
nosis checks that this time is not inordinately long.
Malfunction is detected when the voltage from the sensor is con-
stantly approx. 0.3V.
Possible CauseNBEC0432IHarness or connectors
(The sensor circuit is open or shorted.)
IHeated oxygen sensor 1 (front)
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0130, P0150 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(CIRCUIT)
ECM Terminals and Reference Value (Cont'd)
EC-193
Page 735 of 2395

3 CHECK HEATED OXYGEN SENSOR 1 (FRONT)
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select ªMANU TRIGº and adjust ªTRIGGER POINTº to 100% in ªDATA MONITORº mode with CONSULT-II.
3. Select ªHO2S1 (B1)/(B2)º and ªHO2S1 MNTR (B1)/(B2)º.
4. Hold engine speed at 2,000 rpm under no load during the following steps.
5. Touch ªRECORDº on CONSULT-II screen.
SEF967Y
6. Check the following.
IªHO2S1 MNTR (B1)/(B2)º in ªDATA MONITORº mode changes from ªRICHº to ªLEANº to ªRICHº 5 times in 10 seconds.
5 times (cycles) are counted as shown below.
SEF647Y
IªHO2S1 (B1)/(B2)º voltage goes above 0.6V at least once.
IªHO2S1 (B1)/(B2)º voltage goes below 0.3V at least once.
IªHO2S1 (B1)/(B2)º voltage never exceeds 1.0V.
SEF648Y
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 6.
NG©GO TO 5.
DTC P0130, P0150 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(CIRCUIT)
Diagnostic Procedure (Cont'd)
EC-200
Page 737 of 2395

SEF463R
SEF288D
Component DescriptionNBEC0094The heated oxygen sensor 1 (front) is placed into the front tube. It
detects the amount of oxygen in the exhaust gas compared to the
outside air. The heated oxygen sensor 1 (front) has a closed-end
tube made of ceramic zirconia. The zirconia generates voltage from
approximately 1V in richer conditions to 0V in leaner conditions.
The heated oxygen sensor 1 (front) signal is sent to the ECM. The
ECM adjusts the injection pulse duration to achieve the ideal air-
fuel ratio. The ideal air-fuel ratio occurs near the radical change
from 1V to 0V.
CONSULT-II Reference Value in Data Monitor
Mode
NBEC0095Specification data are reference values.
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 (B1)
HO2S1 (B2)
IEngine: After warming upMaintaining engine speed at 2,000
rpm0 - 0.3V+,Approx. 0.6 - 1.0V
HO2S1 MNTR
(B1)
HO2S1 MNTR
(B2)LEAN+,RICH
Changes more than 5 times during
10 seconds.
ECM Terminals and Reference ValueNBEC0653Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
TERMI-
NAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
63 GHeated oxygen sensor
1 (front) (bank 1)[Engine is running]
IWarm-up condition
IEngine speed is 2,000 rpm.0 - Approximately 1.0V (Peri-
odically change)
SEF059V
DTC P0131, P0151 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(LEAN SHIFT MONITORING)
Component Description
EC-202
Page 739 of 2395

SEF334Z
SEF335Z
SEF651Y
WITH CONSULT-IINBEC0098S011) Start engine and warm it up to normal operating temperature.
2) Stop engine and wait at least 10 seconds.
3) Turn ignition switch ªONº and select ªHO2S1 (B1)/(B2) P0131/
P0150º of ªHO2S1º in ªDTC WORK SUPPORTº mode with
CONSULT-II.
4) Touch ªSTARTº.
5) Start engine and let it idle for at least 3 minutes.
NOTE:
Never raise engine speed above 3,600 rpm after this step. If
the engine speed limit is exceeded, return to step 5.
6) When the following conditions are met, ªTESTINGº will be dis-
played on the CONSULT-II screen. Maintain the conditions
continuously until ªTESTINGº changes to ªCOMPLETEDº. (It
will take approximately 50 seconds or more.)
ENG SPEED 1,300 - 2,800 rpm
Vehicle speed 80 - 100 km/h (50 - 62 MPH)
B/FUEL SCHDL 3 - 10 msec
Selector lever Suitable position
If ªTESTINGº is not displayed after 5 minutes, retry from
step 2.
7) Make sure that ªOKº is displayed after touching ªSELF-DIAG
RESULTSº. If ªNGº is displayed, refer to ªDiagnostic
Procedureº, EC-205.
SEF308XB
Overall Function CheckNBEC0099Use this procedure to check the overall function of the heated oxy-
gen sensor 1 (front) circuit. During this check, a 1st trip DTC might
not be confirmed.
WITH GSTNBEC0099S011) Start engine and warm it up to normal operating temperature.
2) Set voltmeter probes between ECM terminal 63 (HO2S1 bank
1 right signal) or 62 (HO2S1 bank 2 left signal) and engine
ground.
3) Check one of the following with engine speed held at 2,000
rpm constant under no load.
IThe maximum voltage is over 0.6V at least one time.
IThe minimum voltage is over 0.1V at least one time.
4) If NG, go to ªDiagnostic Procedureº, EC-205.
DTC P0131, P0151 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(LEAN SHIFT MONITORING)
DTC Confirmation Procedure (Cont'd)
EC-204
Page 743 of 2395

5 CHECK HEATED OXYGEN SENSOR 1 (FRONT)
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select ªMANU TRIGº and adjust ªTRIGGER POINTº to 100% in ªDATA MONITORº mode with CONSULT-II.
3. Select ªHO2S1 (B1)/(B2)º and ªHO2S1 MNTR (B1)/(B2)º.
4. Hold engine speed at 2,000 rpm under no load during the following steps.
5. Touch ªRECORDº on CONSULT-II screen.
SEF967Y
6. Check the following.
IªHO2S1 MNTR (B1)/(B2)º in ªDATA MONITORº mode changes from ªRICHº to ªLEANº to ªRICHº 5 times in 10 seconds.
5 times (cycles) are counted as shown below.
SEF647Y
IªHO2S1 (B1)/(B2)º voltage goes above 0.6V at least once.
IªHO2S1 (B1)/(B2)º voltage goes below 0.3V at least once.
IªHO2S1 (B1)/(B2)º voltage never exceeds 1.0V.
SEF648Y
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 8.
NG©GO TO 7.
DTC P0131, P0151 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(LEAN SHIFT MONITORING)
Diagnostic Procedure (Cont'd)
EC-208
Page 745 of 2395

SEF463R
SEF288D
Component DescriptionNBEC0101The heated oxygen sensor 1 (front) is placed into the front tube. It
detects the amount of oxygen in the exhaust gas compared to the
outside air. The heated oxygen sensor 1 (front) has a closed-end
tube made of ceramic zirconia. The zirconia generates voltage from
approximately 1V in richer conditions to 0V in leaner conditions.
The heated oxygen sensor 1 (front) signal is sent to the ECM. The
ECM adjusts the injection pulse duration to achieve the ideal air-
fuel ratio. The ideal air-fuel ratio occurs near the radical change
from 1V to 0V.
CONSULT-II Reference Value in Data Monitor
Mode
NBEC0102Specification data are reference values.
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 (B1)
HO2S1 (B2)
IEngine: After warming upMaintaining engine speed at 2,000
rpm0 - 0.3V+,Approx. 0.6 - 1.0V
HO2S1 MNTR
(B1)
HO2S1 MNTR
(B2)LEAN+,RICH
Changes more than 5 times during
10 seconds.
ECM Terminals and Reference ValueNBEC0654Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
TERMI-
NAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
63 GHeated oxygen sensor
1 (front) (bank 1)[Engine is running]
IWarm-up condition
IEngine speed is 2,000 rpm.0 - Approximately 1.0V (Peri-
odically change)
SEF059V
DTC P0132, P0152 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RICH SHIFT MONITORING)
Component Description
EC-210
Page 747 of 2395

SEF336Z
SEF337Z
SEF655Y
WITH CONSULT-IINBEC0105S011) Start engine and warm it up to normal operating temperature.
2) Stop engine and wait at least 5 seconds.
3) Turn ignition switch ªONº and select ªHO2S1 (B1)/(B2) P0132/
P0152º of ªHO2S1º in ªDTC WORK SUPPORTº mode with
CONSULT-II.
4) Touch ªSTARTº.
5) Start engine and let it idle for at least 3 minutes.
NOTE:
Never raise engine speed above 3,600 rpm after this step. If
the engine speed limit is exceeded, return to step 5.
6) When the following conditions are met, ªTESTINGº will be dis-
played on the CONSULT-II screen. Maintain the conditions
continuously until ªTESTINGº changes to ªCOMPLETEDº. (It
will take approximately 50 seconds or more.)
ENG SPEED 1,300 - 2,800 rpm
Vehicle speed 80 - 100 km/h (50 - 62 MPH)
B/FUEL SCHDL 3 - 10 msec
Selector lever Suitable position
If ªTESTINGº is not displayed after 5 minutes, retry from
step 2.
7) Make sure that ªOKº is displayed after touching ªSELF-DIAG
RESULTSº. If ªNGº is displayed, refer to ªDiagnostic
Procedureº, EC-213.
SEF308XB
Overall Function CheckNBEC0106Use this procedure to check the overall function of the heated oxy-
gen sensor 1 (front) circuit. During this check, a 1st trip DTC might
not be confirmed.
WITH GSTNBEC0106S011) Start engine and warm it up to normal operating temperature.
2) Set voltmeter probes between ECM terminal 63 (HO2S1 bank
1 right signal) or 62 (HO2S1 bank 2 left signal) and engine
ground.
3) Check one of the following with engine speed held at 2,000
rpm constant under no load.
IThe maximum voltage is below 0.8V at least one time.
IThe minimum voltage is below 0.35V at least one time.
4) If NG, go to ªDiagnostic Procedureº, EC-213.
DTC P0132, P0152 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RICH SHIFT MONITORING)
DTC Confirmation Procedure (Cont'd)
EC-212
Page 751 of 2395

6 CHECK HEATED OXYGEN SENSOR 1 (FRONT)
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select ªMANU TRIGº and adjust ªTRIGGER POINTº to 100% in ªDATA MONITORº mode with CONSULT-II.
3. Select ªHO2S1 (B1)/(B2)º and ªHO2S1 MNTR (B1)/(B2)º.
4. Hold engine speed at 2,000 rpm under no load during the following steps.
5. Touch ªRECORDº on CONSULT-II screen.
SEF967Y
6. Check the following.
IªHO2S1 MNTR (B1)/(B2)º in ªDATA MONITORº mode changes from ªRICHº to ªLEANº to ªRICHº 5 times in 10 seconds.
5 times (cycles) are counted as shown below.
SEF647Y
IªHO2S1 (B1)/(B2)º voltage goes above 0.6V at least once.
IªHO2S1 (B1)/(B2)º voltage goes below 0.3V at least once.
IªHO2S1 (B1)/(B2)º voltage never exceeds 1.0V.
SEF648Y
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 9.
NG©GO TO 8.
DTC P0132, P0152 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RICH SHIFT MONITORING)
Diagnostic Procedure (Cont'd)
EC-216