SMT968D
1. Current CLUTCH FORCE RELEASE LIMIT value ª0.3 kg-mº
appears under ªCONDITION SETTINGº on CONSULT-II dis-
play.
2. Touch ª1.2º on the display.
SMT969D
3. Display changes to ªNOW ADJUSTINGº in a short time.
SMT970D
4. When clutch force release limit value is set to ª1.2 kg-mº, cur-
rent value ª0.3 kg-mº shown on display will be replaced by ª1.2
kg-mº and ªADJUSTING COMPLETEº will appear at the same
time. Clutch force release limit value setting is now complete.
ON BOARD DIAGNOSTIC SYSTEM DESCRIPTION
Trouble Diagnosis with CONSULT-II (Cont'd)