Symptom:
LEFT CYLINDER LOCK SWITCH INPUT SHORT
When Monitored and Set Condition:
LEFT CYLINDER LOCK SWITCH INPUT SHORT
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage to the cylinder lock switch below .5 volts for
over 10 seconds.
POSSIBLE CAUSES
DTC PRESENT
CYLINDER LOCK SWITCH SHORTED
CYLINDER LOCK SWITCH MUX CIRCUIT SHORTED
BODY CONTROL MODULE - LEFT CYLINDER LOCK SWITCH VOLTAGE SHORTED
TEST ACTION APPLICABILITY
1 NOTE: When this code is present, the VTSS indicator will stay on solid during the
arming process.
With the DRBIIIt, record and erase DTC's.
Cycle the ignition switch from ON to OFF.
With the DRBIIIt, read DTC's.
Operate the door locks several times from the Left Cylinder Lock Switch while
monitoring the DRBIIIt.
Does the DRBIIItdisplay LEFT CYL LOCK SW INPUT SHORT?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 Disconnect the Left Cylinder Lock Switch connector.
With the DRBIIItin Sensors, read the LEFT CYL SW MUX circuit
Is the voltage above 4.6 volts?All
Ye s®Replace the Cylinder Lock Switch.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 3
3 Disconnect the Right Cylinder Lock Switch connector.
Disconnect the Body Control Module C3 connector.
Measure the resistance between Cylinder Lock Switch Mux circuit and ground.
Is the resistance below 1000.0 ohms?All
Ye s®Repair the Cylinder Lock Switch Mux circuit for a short to
ground.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 4
730
POWER DOOR LOCKS/RKE
Symptom:
LEFT CYLINDER LOCK SWITCH INPUT STUCK
When Monitored and Set Condition:
LEFT CYLINDER LOCK SWITCH INPUT STUCK
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage to the cylinder lock switch between 1.3 and
3.25 for over 10 seconds.
POSSIBLE CAUSES
DTC PRESENT
BODY CONTROL MODULE - LEFT CYLINDER LOCK SWITCH VOLTAGE INCORRECT
LEFT CYLINDER LOCK SWITCH GROUND OPEN
LEFT CYLINDER LOCK SWITCH MUX OPEN
CYLINDER LOCK SWITCH STUCK
TEST ACTION APPLICABILITY
1 NOTE: When this code is present, the VTSS indicator will stay on solid during the
arming process.
With the DRBIIIt, record and erase DTC's.
Cycle the ignition switch from ON to OFF.
With the DRBIIIt, read DTC's.
Operate the door lock several times from the Left Cylinder Lock Switch while
monitoring the DRBIIIt.
Does the DRBIIItdisplay LEFT CYL LOCK SW INPUT STUCK?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 With the DRBIIItin Sensors, read the LEFT CYL LOCK SW voltage.
Does the DRBIIItdisplay voltage between 1.3 and 3.25 volts?All
Ye s®Go To 3
No®Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
3 Disconnect the Left Cylinder Lock Switch connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?All
Ye s®Go To 4
No®Repair the Ground circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
732
POWER DOOR LOCKS/RKE
Symptom:
LIFTGATE CYLINDER SWITCH INPUT OPEN
When Monitored and Set Condition:
LIFTGATE CYLINDER SWITCH INPUT OPEN
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage to the cylinder lock switch above 4.6 volts
for over 10 seconds.
POSSIBLE CAUSES
DTC PRESENT
BODY CONTROL MODULE - LIFTGATE CYLINDER SWITCH VOLTAGE LOW
LIFTGATE CYLINDER SWITCH GROUND OPEN
LIFTGATE CYLINDER SWITCH MUX OPEN
LIFTGATE CYLINDER SWITCH OPEN
TEST ACTION APPLICABILITY
1 NOTE: When this code is present, the VTSS indicator will stay on solid during the
arming process.
With the DRBIIIt, record and erase DTC's.
With the DRBIIIt, read DTC's.
Operate the Liftgate Cylinder Switch several times while monitoring the DRBIIIt.
Does the DRBIIItdisplay LGATE CYL SW INPUT OPEN?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 With the DRBIIItin Sensors, read the LGATE CYL SW voltage.
Does the DRBIIItdisplay 4.6 volts or greater?All
Ye s®Go To 3
No®Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
3 Disconnect the Liftgate Cylinder Switch connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?All
Ye s®Go To 4
No®Repair the Ground circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
736
POWER DOOR LOCKS/RKE
Symptom:
LIFTGATE CYLINDER SWITCH INPUT SHORT
When Monitored and Set Condition:
LIFTGATE CYLINDER SWITCH INPUT SHORT
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage to the cylinder lock switch below .5 volts for
over 10 seconds.
POSSIBLE CAUSES
DTC PRESENT
LIFTGATE CYLINDER SWITCH SHORTED
LIFTGATE CYLINDER LOCK SWITCH MUX CIRCUIT SHORTED
BODY CONTROL MODULE - LIFTGATE CYLINDER LOCK SWITCH MUX SHORTED
TEST ACTION APPLICABILITY
1 NOTE: When this code is present, the VTSS indicator will stay on solid during the
arming process.
With the DRBIIIt, record and erase DTC's.
With the DRBIIIt, read DTC's.
Operate the Liftgate Cylinder Switch several times while monitoring the DRBIIIt.
Does the DRBIIItdisplay LGATE CYL LOCK SW INPUT SHORT?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 Disconnect the Liftgate Cylinder Switch connector.
With the DRBIIItin Sensors, read the LGATE CYL SW voltage.
Is the voltage above 4.6 volts?All
Ye s®Replace the Liftgate Cylinder Switch.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 3
3 Disconnect the Liftgate Cylinder Switch connector.
Disconnect the Body Control Module C3 connector.
Measure the resistance between Cylinder Lock Switch Mux circuit and ground.
Is the resistance below 1000.0 ohms?All
Ye s®Repair the Liftgate Cylinder Lock Switch Mux circuit for a short
to ground.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 4
738
POWER DOOR LOCKS/RKE
Symptom:
LIFTGATE CYLINDER SWITCH INPUT STUCK
When Monitored and Set Condition:
LIFTGATE CYLINDER SWITCH INPUT STUCK
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage to the cylinder lock switch between 1.3 and
3.25 for over 10 seconds.
POSSIBLE CAUSES
DTC PRESENT
BODY CONTROL MODULE - LIFTGATE CYLINDER SWITCH VOLTAGE INCORRECT
LIFTGATE CYLINDER SWITCH GROUND OPEN
LIFTGATE CYLINDER LOCK SWITCH MUX OPEN
CYLINDER LOCK SWITCH STUCK
TEST ACTION APPLICABILITY
1 NOTE: When this code is present, the VTSS indicator will stay on solid during the
arming process.
With the DRBIIIt, record and erase DTC's.
With the DRBIIIt, read DTC's.
Operate the Liftgate Cylinder Switch several times while monitoring the DRBIIIt.
Does the DRBIIItdisplay LGATE CYL SW INPUT STUCK?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 With the DRBIIItin Sensors, read the LGATE CYL LOCK SW voltage.
Does the DRBIIItdisplay voltage between 1.3 and 3.25 volts?All
Ye s®Go To 3
No®Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
3 Disconnect the Liftgate Cylinder Switch connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?All
Ye s®Go To 4
No®Repair the Ground circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
740
POWER DOOR LOCKS/RKE
Symptom:
PASSENGER DOOR LOCK SWITCH INPUT OPEN
When Monitored and Set Condition:
PASSENGER DOOR LOCK SWITCH INPUT OPEN
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage to the door lock switch above 4.6 volts for
over 10 seconds.
POSSIBLE CAUSES
DTC PRESENT
BODY CONTROL MODULE - PASSENGER DOOR LOCK SWITCH VOLTAGE LOW
DOOR LOCK SWITCH GROUND OPEN
DOOR LOCK SWITCH MUX OPEN
DOOR LOCK SWITCH OPEN
TEST ACTION APPLICABILITY
1 With the DRBIIIt, record and erase DTC's.
Cycle the ignition from ON to OFF.
With the DRBIIIt, read DTC's.
Operate the door locks several times from the Passenger Door Lock Switch while
monitoring the DRBIIIt.
Does the DRBIIItdisplay PASS DOOR LOCK SW INPUT OPEN?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 With the DRBIIItin Sensors, read the PASS DOOR LOCK SW voltage.
Does the DRBIIItdisplay 4.6 volts or greater?All
Ye s®Go To 3
No®Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
3 Disconnect the Passenger Door Lock Switch connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?All
Ye s®Go To 4
No®Repair the Ground circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
747
POWER DOOR LOCKS/RKE
Symptom:
PASSENGER DOOR LOCK SWITCH INPUT SHORT
When Monitored and Set Condition:
PASSENGER DOOR LOCK SWITCH INPUT SHORT
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage to the door lock switch below .5 volts for
over 10 seconds.
POSSIBLE CAUSES
DTC PRESENT
PASSENGER DOOR LOCK SWITCH SHORTED
DOOR LOCK SWITCH MUX SHORTED
BODY CONTROL MODULE - PASSENGER DOOR LOCK SWITCH VOLTAGE SHORTED
TEST ACTION APPLICABILITY
1 With the DRBIIIt, record and erase DTC's.
Cycle ignition ON to OFF..
With the DRBIIIt, read DTCs.
Operate the door locks several times from the Driver Door Lock Switch while
monitoring the DRBIII.
Does the DRBIIItdisplay DR DOOR LOCK SW INPUT SHORT?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 Disconnect the Passenger Door Lock Switch connector.
With the DRBIIItin Sensors, read the PASS DOOR SW MUX circuit
Is the voltage above 4.6 volts?All
Ye s®Replace the Door Lock Switch.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 3
3 Disconnect the Passenger Door Lock Switch connector.
Disconnect the Body Control Module C3 connector.
Measure the resistance between Door Lock Switch Mux circuit and ground.
Is the resistance below 1000.0 ohms?All
Ye s®Repair the Door Lock Switch Mux circuit for a short to ground.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 4
749
POWER DOOR LOCKS/RKE
Symptom:
PASSENGER DOOR LOCK SWITCH INPUT STUCK
When Monitored and Set Condition:
PASSENGER DOOR LOCK SWITCH INPUT STUCK
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage to the door lock switch between 1.3 and
3.25 for over 10 seconds.
POSSIBLE CAUSES
DTC PRESENT
BODY CONTROL MODULE - PASSENGER DOOR LOCK SWITCH VOLTAGE INCORRECT
DOOR LOCK SWITCH GROUND OPEN
DOOR LOCK SWITCH MUX OPEN
DOOR LOCK SWITCH STUCK
TEST ACTION APPLICABILITY
1 With the DRBIIIt, record and erase DTC's.
Cycle the ignition ON to OFF.
With the DRBIIIt, read DTCs.
Operate the door lock several times from the Passenger Door Lock Switch while
monitoring the DRBIII.
Does the DRBIIItdisplay PASS DOOR LOCK SW INPUT STUCK?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 With the DRBIIItin Sensors, read the PASS DOOR LOCK SW voltage.
Does the DRBIIItdisplay voltage between 1.3 and 3.25 volts?All
Ye s®Go To 3
No®Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
3 Disconnect the Passenger Door Lock Switch connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?All
Ye s®Go To 4
No®Repair the Ground circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
751
POWER DOOR LOCKS/RKE