GENERAL – How to Use Troubleshooting/Inspection Service Points00-10
HOW TO USE THE INSPECTION PROCEDURES
The causes of a high frequency of problems occurring in electronic circuitry are generally the connectors,
components, the ECU and the harnesses between connectors, in that order. These inspection procedures
follow this order, and they first try to discover a problem with a connector or a defective component.
Indicator does not turn on or off even if control
mode switch is pressed.
Indicator switch should not be illuminated is
illuminated.Probable cause
OK
OK
OK
Measure at switch connector A-44
Disconnect the connector, and measure at the harness
side.
Voltage between terminal 6 – earth and terminal 8 –
earth
OK:Approx. 5V
OK
NG
Check the following connector. A-44
Repair
OK
Check trouble symptom.
Replace the ECS-ECU.
In the above cases, the ECS switch circuit is defective or the indicator
circuit is defective.
CHECKING PROCEDURE 4
2. Indicates inspection carried out using the
MUT-II.
Indicates the operation and inspection proce-
dures.
Indicates the OK judgement conditions.
3. Detailed inspection procedures (methods)
such as component inspection and circuit
inspection are listed on a separate page, and
are given here for reference.
5. Inspect the contact condition at each connector terminal.
(Refer to Connector Inspection Service Points.)
The connector position can be located in the wiring diagram in the
electrical wiring manual by means of this symbol.
Caution
After carrying out connector inspection, always be sure to
reconnect the connector as it was before.
6. Confirm that there are trouble symptoms. If trouble symptoms have
disappeared, the connector may have been inserted incorrectly and the
trouble symptom may have disappeared during inspection.
If it seems that trouble symptoms still remain, proceed to the next page of
instructions.
7. If trouble symptoms still remain up to this stage, there is a possibility that there is an
open or short circuit in the harness between the connectors, so check the harness.
Alternatively, the cause may be a defective ECU, so try replacing the ECU and check
if the trouble symptom disappears.
NGECU switch component inspection (Refer to P.3-44.)
NG
1. Comments on the diagnosis code or trouble
symptom above.
MUT-II Data list
17 Control mode selection switch
OK:Voltage changes between approx. 0V → approx.
2.5V → approx. 5V when the switch is operated.
4. Indicates voltage and resistance to be measured at a particular
connector.
(Refer to Connector Measurement Service Points.)
The connector position can be located in the wiring diagram in the
electrical wiring manual by means of this symbol.
Indicates operation and inspection procedures, inspection terminals
and inspection conditions.
Indicates the OK judgement conditions.
HARNESS INSPECTION
Check for an open or short circuit in the harness between the terminals which were defective according
to the connector measurements. Carry out this inspection while referring to the electrical wiring manual.
Here, “Check harness between power supply and terminal xx” also includes checking for blown fuses.
For inspection service points when there is a blown fuse, refer to “Inspection Service Points for a Blown
Fuse.”
MEASURES TO TAKE AFTER REPLACING THE ECU
If the trouble symptoms have not disappeared even after replacing the ECU, repeat the inspection procedure
from the beginning.
MPI – Troubleshooting13-61
8. ACTUATOR TEST REFERENCE TABLE
Item
No.Inspection
itemDrive contentsInspection contentsNormal conditionInspection
procedure
No.Reference
page
01InjectorsCut fuel to No.
1 injectorEngine:
After having warmed
up/Engine is idling
Idling condition
becomes different
(becomes unsta
Code No.
4113-15
02Cut fuel to No.
2 injectorup/Engine is idling
(Cut the fuel supply to each
injector in turn and check
li d hi h d’ff
(becomes unsta-
ble, resulting in
engine stall).
03Cut fuel to No.
3 injector
j
cylinders which don’t affect
idling.)
04Cut fuel to No.
4 injector
07Fuel pumpFuel pump
operates and
fuel is recircu-
lated.Engine:
Cranking
Fuel
pump:
Forced
driving
Inspect ac-
cording to
Pinch the
return hose
with fingers
to feel the
pulse of the
fuel being
recirculated.Pulse is felt.Procedure
No. 2513-36
cording to
both the
above condi-
tions.
Listen near
the fuel tank
for the
sound of
fuel pump
operation.Sound of opera-
tion is heard.
09Fuel
pressure
control
valveSolenoid valve
turns from
OFF to ON.Ignition switch: ONSound of opera-
tion can be heard
when solenoid
valve is driven.Procedure
No. 3413-45
12Waste
gate
solenoid
valveSolenoid valve
turns from
OFF to ON.Ignition switch: ONSound of opera-
tion can be heard
when solenoid
valve is driven.Procedure
No. 3513-45
13Fuel pump
relay No.2Turn fuel
pump relay
No.2 from
OFF to ON.Ignition switch: ON
Listen to pump operation
sound near fuel tank.Sound of opera-
tion can be heard.Procedure
No. 2513-36
17Basic igni-
tion timingSet to ignition
timing adjust-
ment modeEngine: Idling
Timing light is set5BTDC––
REAR AXLE – On-vehicle Service
TORQUE TRANSFER MECHANISM
1. Remove the drain plug to discharge the gear oil.
2. Fit the drain plug and tighten it to the specified torque.
3. Remove the filler plug.
4. Pour the specified gear oil up to the bottom end of the
filler plug hole using an oil syringe (recommended tool)
through the gap between the body and the differential
support arm.
Specified gear oil:
MITSUBISHI GENUINE DIA QUEEN SUPER AYC
FLUID
Quantity used: 0.70
0
0.05
5. Fit the filler plug and tighten it to the specified torque.
FLUID LEVEL CHECK
1. Remove the maintenance lid located in the luggage
compartment.
2.
If the vehicle has been run, leave it for 5 min. or more
in an ordinary temperature (10C to 30C) to allow the
accumulator internal pressure to drop.
NOTE
If the ambient temperature is less than 10C or less,
allow more time to leave the vehicle to stand idle.
Connect the MUT-II to the 16-pin diagnosis connector.
Turn on the ignition switch. Operate the MUT-II (Item
No.11) to activate the hydraulic unit forcibly for removing
the pressure from inside the accumulator.
Caution
Before connecting or disconnecting the MUT-II,
always turn off the ignition switch.
NOTE
(1) The forced activation (oil level check mode) will be
automatically canceled as soon as the directional
valve in the hydraulic unit is activated to the left and
right 20 times.
It can also be canceled forcibly by operating the clear
key on the MUT-II.
(2) While this function is being disabled by the fail-safe
function, the forced activation of the hydraulic unit
can not be executed.
3. Check that the fluid level in the oil reservoir is in the
range between MAX and MIN.
4. If the fluid level is lower than MIN, add the specified
fluid.
Specified fluid: Dia Queen ATF SP II or equivalent
5. Reinstall the maintenance lid.
Gear oil
Drain plug
49 Nm
Oil syringe
(Recommended tool)
Filler plug
49 Nm
REAR AXLE – On-vehicle Service
BLEEDING
1. Lift up the vehicle.
2. Connect the MUT-II to the 16-pin diagnosis connector.
Caution
Before connecting or disconnecting the MUT-II,
always turn off the ignition switch.
3. Turn on the ignition switch.
4. Operate the MUT-II (Item No.10) to activate the hydraulic
unit forcibly.
NOTE
(1) The forced activation (air bleeding mode) will be
automatically canceled after 5 minutes operation. It
can also be canceled forcibly by operating the clear
key on the MUT-II.
(2) While this function is being disabled by the fail-safe
function, the forced activation of the hydraulic unit
can not be executed.
5. Remove the cap of the left bleeder screw on the torque
transfer differential and connect a vinyl hose.
6. Gradually turn the steering wheel clockwise from the
straight-ahead position. At this time, loosen the left bleeder
screw and check that fluid is discharged with air.
7. After air has been completely discharged, tighten the
bleeder screw.
Caution
While the system is being bled of air, add fluid as
necessary to ensure that it is left in the oil reservoir
during the entire procedure.
8. Repeat steps (6) and (7) two to three times until no air
bubbles are recognized in the fluid that comes out. Then,
tighten the bleeder screw to the specified torque.
Tightening torque: 9 Nm
9. Perform steps (5) through (8) for the right bleeder screw.
Note, however, that the steering wheel should be turned
counterclockwise.
10. After the system has been completely bled of air, check
for the fluid level. (Refer to P.27-33.)
Caution
If the system is not completely bled of air, the hydraulic
unit could generate noise, degrading pump durability.
AYC OPERATION CHECK
1. Lift up the vehicle.
2. Connect the MUT-II to the 16-pin diagnosis connector.
Caution
Before connecting or disconnecting the MUT-II, always
turn off the ignition switch.
3. Start the engine.
4. Operate the MUT-II with the transmission in 2nd or a
higher gear and check to ensure that the vehicle speed
is higher than 10 km/h using the Data List (Item 10).
Bleeder
screws Vinyl hose
REAR AXLE – On-vehicle Service
(2) While this function is being disabled by the fail-safe
function, the forced activation of the hydraulic unit
can not be executed.
6. Check to ensure that the hydraulic pressure generated
by the hydraulic unit conforms to the standard value.
Standard value: 1.0 – 1.6 MPa
NOTE
During checking the hydraulic pressure, occasionally
replenish the oil reservoir with fluid so that it does not
become empty.
7. Check the hydraulic pressure of the clutch right side by
repeating the steps (4) through (6). At this time, however,
the special tool must be connected to the R port and
the blind plug or the R port of the removed hydraulic
unit hose assembly must be attached to the L port. Further,
the MUT-II must be operated in the forced activation mode
Item No. 14 (clutch right side operation check mode).
8. If the measured value exceeds the standard value, replace
the hydraulic unit.
9. Connect the hydraulic unit hose assembly to the hydraulic
unit and to the torque transfer differential and tighten
the flare nuts to the specified torque.
Specified torque: 34 Nm
10. Pour the specified fluid in the oil reservoir up to the MAX
mark. Then, bleed the system.
Specified fluid: Dia Queen ATF SP II or equivalent
Fluid amount used: Approx. 1
DIFFERENTIAL CARRIER OIL SEAL
REPLACEMENT
DIFFERENTIAL
1. Remove the drive shaft.
2. Remove the oil seal from the differential carrier.
3. Using the special tool, drive a new oil seal all the way
into position.
4. Coat the oil seal lips and the drive shaft surface in contact
with the oil seal with multi-purpose grease.
5. Replace the drive shaft circlip with a new one and mount
the drive shaft to the differential carrier.
6. Check for correct wheel alignment.
TORQUE TRANSFER MECHANISM
1. Remove the drive shaft.
2. Remove the oil seal from the differential carrier.
3. Using the special tool, drive a new oil seal all the way
into position.
4. Coat the oil seal lips and the drive shaft surface in contact
with the oil seal with the specified grease.
Specified grease: Vaseline
5. Replace the drive shaft circlip with a new one and mount
the drive shaft to the differential carrier.
6. Check for correct wheel alignment.
MB990938
MB991115
MD998829
MD998812
MD998813
BODY – Keyless Entry System42-8
ASSEMBLY SERVICE POINTS
ABATTERY INSTALLATION
Install a new battery with (+) side upward.
Battery required for replacement:
Lithium battery CR1216
SECRET CODE REGISTRATION METHOD
Each individual secret code is registered inside
the transmitter, and so it is necessary to register
these codes with the EEPROM inside the receiver
in the following cases.
When either the transmitter or receiver is
replaced;
If it appears that a problem is occurring because
of faulty registration of a code.
A maximum of two different codes can be stored
in the memory area of the EEPROM (two different
transmitters can be used). When the code for the
first transmitter is registered, the previously-regis-
tered codes for two transmitters are cleared.
Therefore, if you are using two transmitters or are
adding a second transmitter, the codes for both
transmitters must be registered at the same time.
Before beginning with the registration, check that
the doors lock normally when the key is used.
1. Connect the MUT-II to the diagnosis connector.
NOTE
This will connect terminal (1) of the diagnosis
connector to earth, and the system will be in
secret code registration standby mode.
Caution
Always turn the ignition switch to OFF before
connecting and disconnecting the MUT-II.
2. Close all the doors.
3. Turn the ignition switch to ACC and then back
to OFF.NOTE
The doors will lock and unlock once at this
time and the system will switch to registration
mode.
4. Press the transmitter switch, and then press
it two times within 10 seconds of the first press.
This will register the code.
5. After registration is completed, the doors will
be automatically locked and unlocked once.
6. If you are using two transmitters or have added
a second transmitter, the same registration
procedure should be carried out for the second
transmitter, and it should be carried out within
one minute after registration of the code for
the first transmitter has been completed. After
the second registration is completed, the doors
will be automatically locked and unlocked once.
7. Registration mode will be cancelled if one of
the following conditions is met.
When the secret codes for two transmitters
have been registered;
When 1 minute has passed after
registration mode started;
If the MUT-II is disconnected (the earth
connection is broken);
If the ignition switch is turned to ON;
If any of the doors are opened;
8. After registration is completed, carry out the
following to check if the keyless entry system
is operable properly.
Remove the ignition key.
Close all the doors.