1998 HONDA CR-V Workshop Manual

Page 1289 of 1395

HONDA CR-V 1998 RD1-RD3 / 1.G Workshop Manual 
Passengers Door Lock Actuator Test
Remove the passengers door panel (see section 20).
Disconnect the 2P connector from the actuator.
NOTE: The left rear door lock actuator is shown;
the front passe

Page 1290 of 1395

HONDA CR-V 1998 RD1-RD3 / 1.G Workshop Manual 
Power Door Locks
Transmitter Test (With Keyless Entry Systeml
NOTE:
. The ceiling light (in middle position) comes on within 30 seconds when you unlock the doors with the transmitter.
. The doors do

Page 1291 of 1395

HONDA CR-V 1998 RD1-RD3 / 1.G Workshop Manual 
Transmitter Programming
Storing transmitter codes:
The codes of up to three transmitters can be read into
the kevless receiver unit memory (lf a fourth code is
stored. the code which was inDUt first

Page 1292 of 1395

HONDA CR-V 1998 RD1-RD3 / 1.G Workshop Manual 
Power Windows
Component Location Index
FRONT PASSCNGERSWINDOW MOTORTest, page 23-137POWER WINDOW MASTERSWITCH(Has built in control unit)Input Test, page 23-134Test, page 23-135
RIGHT REAR WINDOWMOT

Page 1293 of 1395

HONDA CR-V 1998 RD1-RD3 / 1.G Workshop Manual 
Gircuit Diagram
L]NDEF H@O FISETRELAY BOX
@-*
rblr (r0oA) rlo42t40A)
V
I
PASSENGEAS
FFONT PASSENGEFS
23-133
www.emanualpro.com

Page 1294 of 1395

HONDA CR-V 1998 RD1-RD3 / 1.G Workshop Manual 
Power Windows
Master Switch Input Test
NOTE: The control unit is built into the power window master switch and only controls drivers door window operations.
1. Remove the master switch, and disconne

Page 1295 of 1395

HONDA CR-V 1998 RD1-RD3 / 1.G Workshop Manual 
-
CavityWi1€Test conditionTesi: Dssired rosultPo$ible cause if 183uh is not obtained
A11
BLK
Under all conditionsCheck for continuity to ground:
There should be continuity.
. Poor ground (G551)
. A

Page 1296 of 1395

HONDA CR-V 1998 RD1-RD3 / 1.G Workshop Manual 
Power Windows
1.
Master Switch Test
Remove the switch (see section 20).
Disconnect the 14P, 2P and 1P connectors from the
power window master switch.
Check for continuity between the terminals in eac