1997 SUBARU LEGACY torque

[x] Cancel search: torque

Page 886 of 3342

SUBARU LEGACY 1997  Service Repair Manual G3M0434
2) Installation and adjustment of inhibitor switch
(1) Install the inhibitor switch to the transmission case.
Fit the projecting portion of the switch in the recessed
portion of the case, and

Page 887 of 3342

SUBARU LEGACY 1997  Service Repair Manual G3M0332
6) Install the oil charge pipe.
Tightening torque:
Upper
41±3 N⋅m (4.2±0.3 kg-m, 30.4±2.2 ft-lb)
Lower
6.4±0.5 N⋅m (0.65±0.05 kg-m, 4.7±0.4 ft-lb)
CAUTION:
Be careful not to damage t

Page 888 of 3342

SUBARU LEGACY 1997  Service Repair Manual B3M0630A
11) Insert the input shaft while turning lightly by hand.
CAUTION:
Be careful not to damage the bushing.
Normal protrusion A:
2200 cc: 50—55 mm (1.97—2.17 in)
2500 cc: 28—32 mm (1.10—

Page 891 of 3342

SUBARU LEGACY 1997  Service Repair Manual 6. Control Valve Body
The control valve is composed of parts which are accu-
rately machined to a high degree and should be handled
carefully during disassembly and assembly. As these parts
are simila

Page 892 of 3342

SUBARU LEGACY 1997  Service Repair Manual Unit: mm (in)
No. Part name Wire dia. Outer dia. Effective turn Free length
25 Pressure regulator spring 1.6 (0.063) 14.0 (0.551) 5.6 31.5 (1.240)
26 Pressure modifier spring 0.8 (0.031) 6.8 (0.268) 1

Page 895 of 3342

SUBARU LEGACY 1997  Service Repair Manual G3M0906
5) Temporarily assemble lower valve body to upper valve
body.
CAUTION:
Be careful not to drop the upper body interior steel
ball, or the lower body interior filter, orifice check
spring, or or

Page 898 of 3342

SUBARU LEGACY 1997  Service Repair Manual G3M0454
2) Install the vane ring, rotor and vanes into the housing
in this sequence.
G3M0455
3) Install the return spring and retainer between the hous-
ing and cam ring.
G3M0456
4) Install the contro

Page 900 of 3342

SUBARU LEGACY 1997  Service Repair Manual G3M0461
C: ASSEMBLY
1) Measure dimension“A”of the drive pinion shaft.
G3M0462
2) Using a press, force-fit the roller bearing in position.
CAUTION:
Do not change the relative positions of the outer