1993 FORD MONDEO light

[x] Cancel search: light

Page 85 of 279

FORD MONDEO 1993  Service Repair Manual to the engine bearings, the acid attacks and
corrodes the bearing material.
7Incorrect shell refitting during engine
assembly will lead to bearing failure as well.
Tight-fitting shells leave insuffici

Page 86 of 279

FORD MONDEO 1993  Service Repair Manual (see illustration). Next, install the upper side
rail in the same manner.
8After the three oil ring components have
been installed, check that both the upper and
lower side rails can be turned smoothl

Page 88 of 279

FORD MONDEO 1993  Service Repair Manual rod’s big-end onto the crankpin. The piston
rings may try to pop out of the ring
compressor just before entering the cylinder
bore, so keep some pressure on the ring
compressor. Work slowly, and if

Page 93 of 279

FORD MONDEO 1993  Service Repair Manual sender’s electrical connector, and use a
jumper wire to connect the white/red wire to a
clean earth point (bare metal) on the engine.
Switch on the ignition without starting the
engine. If the gauge

Page 95 of 279

FORD MONDEO 1993  Service Repair Manual Heater blower motor
Removal
1Disconnect the battery negative (earth) lead
(see Chapter 5, Section 1).
2Release the four clips (by pulling them out)
securing the passenger side footwell upper
trim pane

Page 97 of 279

FORD MONDEO 1993  Service Repair Manual the refrigerant. The liquid refrigerant boils off
into low-pressure vapour, taking the heat with
it when it leaves the evaporator.
Precautions
Warning: The air conditioning
system is under high pressu

Page 100 of 279

FORD MONDEO 1993  Service Repair Manual This Chapter is concerned with those
features of the engine management system
that supply clean fuel and air to the engine,
meter it in the required proportions, and
dispose of the results. Since the

Page 103 of 279

FORD MONDEO 1993  Service Repair Manual which pulley, disconnect the first cable end
nipple from the throttle actuator’s upper
pulley, then slide the cable outer upwards out
of the actuator housing. Disconnect the
second cable in the same