Page 474 of 698

472
Owners Manual_Europe_M52N75_en
7-2. Steps to take in an emergency
If you have a set of jumper (or
booster) cables and a second vehi-
cle with a 12-volt battery, you can
jump start your vehicle by following
the steps below.
1 Vehicles with an alarm (P. 8 6 ) :
Confirm that the electronic key
is being carried.
When connecting the jumper (or booster) cables, depending on the situ-
ation, the alarm may activate and doors
locked. ( P. 8 7 )
2Open the hood (P.380) and
fuse box cover.
3 Open the exclusive jump start-
ing terminal cover.
4 Connect a positive jumper cable clamp to on your vehicle and con-
nect the clamp on the other end of the positive cable to on th e sec-
ond vehicle. Then, connect a negative cable clamp to on the se cond
If the 12-volt batter y is
discharged
The following procedures may
be used to start the hybrid sys-
tem if the 12-volt battery is dis-
charged.
You can also call any autho-
rized Toyota retailer or Toyota
authorized repairer, or any reli-
able repairer or a qualified
repair shop.
Restarting the hybrid sys-
tem
Page 475 of 698

473
7
Owners Manual_Europe_M52N75_en
7-2. Steps to take in an emergency
When trouble arises
vehicle and connect the clamp at the other end of the negative cable to
.
Exclusive jump starting terminal (your vehicle)
Positive (+) battery terminal (second vehicle)
Negative (-) battery terminal (second vehicle)
Solid, stationary, unpainted metallic point away from the exclu sive jump
starting terminal and any moving parts as shown in the illustra tion
5 Start the engine of the second
vehicle. Increase the engine
speed slightly and maintain at
that level for approximately 5
minutes to recharge the 12-volt
battery of your vehicle.
6 Vehicles with a smart entry &
start system: Open and close
any of the doors of your vehicle
with the power switch OFF.
7 Maintain the engine speed of
the second vehicle and start the
hybrid system of your vehicle by
turning the power switch to ON.
8 Make sure the “READY” indica-
tor comes on. If the indicator
does not come on, contact any
authorized Toyota retailer or
Toyota authorized repairer, or
any reliable repairer.
9 Once the hybrid system has
started, remove the jumper
cables in the exact reverse
order from which they were con-
nected.
10 Close the exclusive jump start-
ing terminal cover and install the
fuse box cover to its original
position.
Once the hybrid system starts,
have the vehicle inspected at any
authorized Toyota retailer or Toyota
Page 477 of 698

475
7
Owners Manual_Europe_M52N75_en
7-2. Steps to take in an emergency
When trouble arises
●When removing the 12-volt battery:
P. 3 8 8
●After replacing, firmly attach the fol-
lowing items to the exhaust hole of the 12-volt battery.• Use the exhaust hose that was
attached to the 12-volt battery before replacing and confirm that it is firmly connected to the hole section of the
vehicle. • Use the exhaust hole plug included with the 12-volt battery replaced or the
one installed on the 12-volt battery prior to the replacement. (Depending on the 12-volt battery to be replaced,
the exhaust hole may be plugged.)
Exhaust hole
Exhaust hole plug
●For details, consult any authorized Toyota retailer or Toyota authorized
repairer, or any reliable repairer.
WARNING
■When removing the 12-volt bat- tery terminals
Always remove the negative (-) termi- nal first. If the positive (+) terminal contacts any metal in the surrounding
area when the positive (+) terminal is removed, a spark may occur, leading to a fire in addition to electrical shocks
and death or serious injury.
■Avoiding 12-volt battery fires or explosions
Observe the following precautions to
prevent accidentally igniting the flam- mable gas that may be emitted from the 12-volt battery:
●Make sure each jumper cable is connected to the correct terminal
and that it is not unintentionally in contact with any other than the intended terminal.
●Do not allow the other end of the jumper cable connected to the “+”
terminal to come into contact with any other parts or metal surfaces in the area, such as brackets or
unpainted metal.
●Do not allow the + and - clamps of
the jumper cables to come into con- tact with each other.
●Do not smoke, use matches, ciga-rette lighters or allow open flame near the 12-volt battery.
■12-volt battery precautions
The 12-volt battery contains poison-
ous and corrosive acidic electrolyte, while related parts contain lead and lead compounds. Observe the follow-
ing precautions when handling the 12-volt battery:
●When working with the 12-volt bat-tery, always wear safety glasses and take care not to allow any bat-
tery fluids (acid) to come into con- tact with skin, clothing or the vehicle body.
●Do not lean over the 12-volt battery.
●In the event that battery fluid comes into contact with the skin or eyes, immediately wash the affected area
with water and seek medical atten- tion. Place a wet sponge or cloth over the affected area until medical
attention can be received.
Page 478 of 698

476
Owners Manual_Europe_M52N75_en
7-2. Steps to take in an emergency
WARNING
●Always wash your hands after han- dling the 12-volt battery support,
terminals, and other battery-related parts.
●Do not allow children near the 12-volt battery.
■After recharging the 12-volt bat-tery
Have the 12-volt battery inspected at
any authorized Toyota retailer or Toyota authorized repairer, or any reli-able repairer as soon as possible.
If the 12-volt battery is deteriorating, continued use may cause the 12-volt battery to emit a malodorous gas,
which may be detrimental to the health of passengers.
■When replacing the 12-volt bat-tery
●For information regarding 12-volt
battery replacement, contact any authorized Toyota retailer or Toyota authorized repairer, or any reliable
repairer.
●After replacing, securely attach the exhaust hose and exhaust hole plug to the exhaust hole of the
replaced 12-volt battery. If not prop- erly installed, gases (hydrogen) may leak into the vehicle interior,
and there is the possible danger of the gas igniting and exploding.
NOTICE
■When handling jumper cables
When connecting the jumper cables, ensure that they do not become entangled in the cooling fan, etc.
■To prevent damaging the vehicle
The exclusive jump starting terminal
is to be used when charging the 12- volt battery from another vehicle in an emergency. It cannot be used to jump
start another vehicle.