Page  23   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  6.4.3   Redu ction of the likelihood of ignition under single 
fault conditions in PS2 and PS3 circuits     N/A  
6.4.3.1    Supplementary safeguards     N/A  
6.4.3.2   Single Fault Conditions   ................................ ..........   :     N/A  
  Special conditions for temperature limited by fuse     N/A  
6.4.4   Control of fire  spread in PS1 circuits     P  
6.4.5   Control of fire spread in PS2 circuits     P  
6.4.5.2   Supplementary safeguards   For conductor and devices are 
mounted   on  printed board 
made of  Min. V - 1.  
Other components in PS2   are  
mounted on printed board 
made of   Min.   V - 1   and  PVC 
wire used .  
Not ignite during single fault 
condition .   P  
6.4.6   Control of fire spread in PS3 circuits   Provided  Metallic   enclosure   P  
6.4.7   Separation of combustible materials from a PIS     P  
6.4.7.2   Separation by distance     N/A  
6.4.7.3   Separation by a f ire barrier     P  
6.4.8   Fire enclosures and fire barriers     P  
6.4.8.2   Fire enclosure and fire barrier material properties     P  
6.4.8.2.1   Requirements for a fire barrier   V - 0 class material or metal, 
Printed board made of V - 0   P  
6.4.8.2.2   Requirem ents for a fire enclosure   Metallic   enclosure provided   P  
6.4.8.3   Constructional requirements for a fire enclosure 
and a fire barrier     P  
6.4.8.3.1   Fire enclosure and fire barrier openings     P  
6.4.8.3.2   Fire barrier dimensions     P  
6.4.8.3.3   Top openings and   properties   E quipment for building - in ,  
e valuation shall be considered 
in the end product   N/A  
  Openings dimensions (mm)   ................................ ...   :     N/A  
6.4.8.3.4   Bottom openings and properties   E quipment for building - in ,  
e valuation shall be considered 
in the end product   N/A  
  Open ings dimensions (mm)   ................................ ...   :     N/A  
  Flammability tests for the bottom of a fire enclosure     N/A   

   
 
Page  32   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  F.3.3.6   Rated current or rated power   ................................   :   See copy of marking plate   P  
F.3.3.7   Equipment with multiple supply connections     N/A  
F.3.4   Voltage setting device     N/A  
F.3.5   Terminals and operating devices     N/A  
F.3.5.1   Mains appliance outlet an d socket - outlet markings
  ................................ ................................ ...............   :   No such component   N/A  
F.3.5.2   Switch position identification marking ....................   :    No such component   N/A  
F.3.5.3   Replacement fuse identification and rating 
markings   ................................ ................................   :   No  replaceable   fuse   N/A  
  Instructional safeguards for neutral fuse   ...............   :   N o such component   N/A  
F.3.5.4   Replacement battery identification marking   ..........   :   No replaceable battery   N/A  
F.3.5.5   Neutral conductor terminal     N/A  
F.3.5.6   Terminal marking location     N/A  
F.3.6   Equipment markings related to equipment 
classification     N/A  
F.3.6 .1   Class I equipment     N/A  
F.3.6.1.1   Protective earthing conductor terminal   ..................   :     N/A  
F.3.6.1.2   Protective bonding conductor terminals    ...............   :     N/A  
F.3.6.2   Equipment class marking   ................................ ......   :     N/A  
F.3.6.3   Functional earthing terminal marking   ....................   :     N/A  
F.3.7   Equipment IP ra ting marking   ................................ .   :     N/A  
F.3.8   External power supply output marking   ..................   :     N/A  
F.3.9   Durability, legibility and permanence of marking     P  
F.3.10   Test for permanence of markings     P  
F.4   Instructions  
N/A  
  a) Information prior to installation and initial use   It sha ll be evaluated in the 
end - equipment   N/A  
  b) Equipment for use in locations where children not 
likely to be present     N/A  
  c) Instructions for installation and interconnection     N/A  
  d) Equipment intended for use only in restricted 
access area      N/A  
  e)  Equipment intended to be fastened in place     N/A  
  f) Instructions for audio equipment terminals      N/A  
  g) Protective earthing used as a safeguard     N/A   

   
 
Page  49   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
5.5.2.2   TABLE: Stored discharge on capacitors  
N/A  
Location   Supply voltage (V)   Operating and fault 
condition   1)
  Switch 
position   Measured 
voltage 
(Vpk)   ES Class  
           
Supplementary information:  
X - capacitors installed for testin g:    
  bleeding resistor rating:    
  ICX:   
1)   Normal operating condition (e.g., normal operation, or open fuse), SC= short circuit, OC= open circuit  
 
5.6.6   TABLE: Resistance of protective conductors and terminations   
N/A  
Loca tion   Test current  
(A)   Duration  
(min)   Voltage drop  
(V)   Resistance  
( Ω )  
         
Supplementary information:   
 
5.7.4   TABLE: Unearthed accessible parts  
N/A  
Location    Operating and 
fault conditions   Supply 
Voltage (V)   Parameters   ES 
class  
Voltage       
(V
rms   or V
pk )   Current      
(A
rms   or A
pk )   Freq.  
(Hz)  
             
Supplementary information:  
Abbreviation: SC= short circuit; OC= open circuit  
 
5.7.5   TABLE: Earthed accessible conductive part  
N/A  
Supply voltage (V)   ...........................   :    
  
Phase(s)    ................................ .........   :   []   Single Phase;  [ ]   Three Pha se : [   ] Delta  [ ] W ye    
Power Distribution System    .............   :     TN              TT              IT
 
 
Location   Fault Condition No   in IEC 
60990 clause 6.2.2   Touch current 
(mA)   Comment  
       
Supplementary Information:      
 
  

   
 
Page  53   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  16. Power key knob body   25.5   29.5   -     60  
17. Enclosure   near media button   28.6   32.6   -     77  
18. Frame body (Not accessible)   34.4   -   98.4     -  
19. Metal enclosure body (Not accessible)   40.4   -   104.4     -  
Ambient temperature   See 
above   See 
above   See 
above     -  
Temperature T of winding:   t
1   (°C)  
R
1   (  )   t
2   (°C)  
R
2   (  )   T (  C)   Allowed 
T
max   (  C)   Insulation 
class  
               
Supplementary information:  
Note 1. The temperatures for accessible parts are adjusted to reflect a value of 25 °C .  
Note 2. Maximum operating Temperature pe rmitted by the Manufacturer(Tma) is  85    C .  
 
 
 
B.2.5   TABLE: Input test  
P  
U (V)   Hz   I (A)   I rated (A)   P (W)   P rated (W)   Fuse No   I fuse (A)   Condition/status  
10.2   -  
2.31   -  
23.56   -   -   -  
Max. normal 
load condition.  
12.0   -  
2.20   3.5  
26.40   -   -   -  
Max. normal 
load condition.  
14.4   -  
2.16   -  
31.10   -   -   -  
Max. normal 
lo ad condition.  
Supplementary information:  
Max. normal load condition :  The  equipment   is operated in such a way as to deliver one - eighth of the NON -
CLIPPED   OUTPUT POWER to the RATED LOAD IMPEDANCE ( 4Ω )   using the standard signal described 
in  Annex E and  Max.  brightness for LCD module.  
 
  

   
 
Page  54   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
B.3, B.4   TABLE: Abnormal operating and fault condition tests  
P  
Ambient temperature T
amb   (  C)   ................................ .....................   :   2 1 - 2 3  
  
Power source for EUT: Manufacturer, model/type, outputrating   ..   :   -  
  
Component No.   Condition   Supply 
voltage 
(V)   Test 
tim e   Fuse no.   Fuse 
current 
(A)   Observation  
Ventilation 
openings   Block ed   14.4   2   h   -   -   FI   :  2.16   A, NO,   
CT (Monitor  body   : 3 8.0    C,  
Power key knob body   :  2 6.1  
 C,  Enclosure near media 
button   : 29.4   C,   Ambient : 
2 1.2    C, NCD, NH  
Speaker output   Max. non -
clipp ed output   14.4   2   h   -   -   FI  : Max.  3.43   A, NO,   
CT ( Amp IC body (IC163) : 
80.4   C ,   Monitor  body   : 3 8.0  
 C,   Power key knob body   : 
26.3    C,  Enclosure near 
media button   : 29.5   C,  
Ambient : 2 1.5    C, NCD, NH  
Speaker output   SC   14.4   1   h   -   -   FI  :  0.5  -   1.5 5   A ,  IP ,   NCD, 
NH  
IC101(3,8)   SC   14.4   1   h   -   -   FI  :  0.5 A ,  CD(IC101) , NH  
IC902(1,6)   SC   14.4   1   h   -   -   FI  :  0.5 A ,  CD(IC902) , NH  
Supplementary information:  
Abbreviation:   
FI  –   Final Input Current; IP  –   Internal protection operated;   NO  –   Normal Operated;  
CD  –   Componen t Damaged (list damaged components); NCD  –   No Component Damaged;  
NH  –   No Hazard ;  CT  –   Constant temperatures were obtained (list components: temperature;);  
NB  –   No indication of dielectric breakdown; YB  –   Dielectric breakdown (indicate time and location);  
NC  –   Cheesecloth remained intact; YC  –   Cheesecloth charred or flamed;  
  

   
 
Page  58   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
4.1.2   TABLE: Critical components information  
P  
Object / part No.   Manufacturer/  
trademark   Type / model   Technical data   S tandard   Mark(s) of 
conformity 1)
 
Plastic 
Enclosure   LG CHEM LTD   LUPOY GN -
5007F(#)   V - 0   UL 94   UL   ( E67171 )  
Alternate   Interchangeable   Interchangeable   Min.  HB   UL 94   UL  
-   Description:   Interchangeability based on specified ratings  
Metal Enclosure   Interchangeabl e   Interchangeable   AL or EGI(SECC)  
or GI(SGCC) or   
NI or ALDC or   
MG or SUS or   
STS or NSP or   
STEEL, Min. 0.4   
thickness   IEC 62368 - 1   Tested in 
equipment    
-   Description:   Interchangeability based on specified ratings and dimensions  
PCB   ZHEJIANG 
HUABANG 
ELE CTRONICS 
CO LTD   H - 01   V - 0   UL 796   UL   ( E251053 )  
Alternate   HYUN WOO 
INDUSTRIAL 
CO LTD   3   V - 0   UL 796   UL (E131308)  
Alternate    Interchangeable   Interchangeable   Min. V - 1   UL 796   UL  
-   Description:   Interchangeability based on specified ratings  
LCD Panel   LG Display   Co., 
Ltd.   LA065WV1   6.5 inch ,    
( 800   x   480  )   IEC 62368 - 1   Tested in 
equipment    
Alternate   LG Display 
(Paju) Co., Ltd.   LA065WV3   6.5 inch ,    
( 800   x   480  )   IEC 60065   T Ü V - Rh  
(JPTUV -
080511)  
Alternate   Giantplus 
Technology Co., 
LTD.   GPM1696A0   6.5 inch ,    
( 800   x   480  )   IEC 60065   SGS F imko  
(FI - 37636)  
Mains connector 
material   KURARAY CO 
LTD   GN2330(#)   V - 0   UL 94   UL (E90350)  
Alternate   Interchangeable   Interchangeable   Min. V - 1   UL   94   UL  
-   Description:   Inte rchangeability based on specified ratings  
Fuse   ST   VN5E010MHTR -
E   13A Switch off   ISO/TS 
16949:2009   9136.STM2  
Supplementary information:  
1) 
Provided evidence ensures the agreed level of compliance. See OD - 2039.   

   
 
Page  60   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
  For special national conditions, see Annex ZB.  
1   Add   the following note:  
NOTE Z1  The use of certain substances in electrical and electronic 
equipment is restricted   within the EU: see Directive 2011/65/EU.     P  
4.Z1   Add   the following new subclause after 4.9:  
To protect against excessive current, short - circuits and 
earth faults in circuits connected to an a.c.  mains , 
protective devices shall be included either as integ ral 
parts of the equipment or as parts of the building 
installation, subject to the following, a), b) and c):  
a) except as detailed in b) and c), protective devices 
necessary to comply with the requirements of B.3.1 and 
B.4 shall be included as parts of th e equipment;  
b) for components in series with the mains input to the 
equipment such as the supply cord, appliance coupler, 
r.f.i. filter and switch, short - circuit and earth fault 
protection may be provided by protective devices in the 
building installation ;  
c) it is permitted for  pluggable equipment type B   or 
permanently connected equipment , to rely on 
dedicated overcurrent and short - circuit protection in the 
building installation, provided that the means of 
protection, e.g. fuses or circuit breakers, is fu lly 
specified in the installation instructions.  
If reliance is placed on protection in the building 
installation, the installation instructions shall so state, 
except that for  pluggable equipment type A   the 
building installation shall be regarded as provid ing 
protection in accordance with the rating of the wall 
socket outlet.     N/A  
5.4.2.3.2.4   Add   the following to the end of this subclause:  
The requirement for interconnection with  external 
circuit   is in addition given in EN 50491 - 3:2009.     N/A  
10.2.1   Add th e following to  c)
  and  d)
  in table 39:  
For additional requirements, see 10.5.1.     N/A   

   
 
Page  65   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
 5.5.6   Finland, Norway  and   Sweden  
To the end of the subclause the following is added:  
Resistors used as  basic safeguard   or bridging  basic 
insulation   in  class I pluggable equipment   type A  
shall comply w ith G.10.1 and the test of G.10.2.     N/A  
5.6.1   Denmark  
Add   to the end of the subclause  
Due to many existing installations where the socket -
outlets can be protected with fuses with higher rating 
than the rating of the socket - outlets the protection for 
plugg able equipment type A shall be an integral part of 
the equipment.  
Justification:  
In Denmark an existing 13 A socket outlet can be 
protected by a 20 A fuse.     N/A  
5.6.4.2.1   Ireland and United Kingdom  
After the indent for  pluggable equipment type A , the 
foll owing is added:  
–   the  protective current rating   is taken to be 13 A, this 
being the largest rating of fuse used in the  mains   plug.     N/A  
5.6.5.1   To the second paragraph the following is added:  
The range of conductor sizes of flexible cords to be 
accepted b y terminals for equipment with a rated 
current over 10 A and up to and including 13 A is:  
1,25 mm 2
  to 1,5 mm 2
  in cross - sectional area.     N/A  
5.7.5   Denmark  
To the end of the subclause the following is added:  
The installation instruction shall be affixed to  the 
equipment if the  protective conductor current  
exceeds the limits of 3,5 mA a.c. or 10 mA d.c.     N/A