CHG-16
< BASIC INSPECTION >
DIAGNOSIS AND REPAIR WORKFLOW
>> GO TO 2.
2.STOP POWER GENERATION VOLTAGE VARIABLE CONTROL SYSTEM
Stop the operation of the power generation voltage variabl e control in either of the following procedures.
• After selecting “ENGINE” using CONSULT, set the DUTY value of “ALTERNATOR DUTY” to 0 % by select-
ing “ALTERNATOR DUTY” of “Active Test”. Continue “Active Test” until the end of inspection. (When the
DUTY value is 0 or 100 %, the normal power generation is performed according to the characteristic of the
IC regulator of the generator.)
• Turn the ignition switch OFF, and disconnect the batte ry current sensor connector. [However, DTC (P1550–
P1554) of the engine might remain. After finishing the inspection, connect the battery current sensor connec-
tor and erase the self diagnosis results history of the engine using CONSULT.]
>> GO TO 3.
3.DIAGNOSIS WITH EXP-800 NI OR GR8-1200 NI
Perform the charging system test using Multitasking battery and electrical diagnostic station GR8-1200 NI or
Battery and electrical diagnostic analyzer EXP-800 NI. Refer to the applicable Instruction Manual for proper
testing procedures.
Te s t r e s u l t
NO PROBLEMS>>Charging system is normal and will also show “DIODE RIPPLE” test result.
NO VOLTAGE>>GO TO 4.
LOW VOLTAGE>>GO TO 12.
HIGH VOLTAGE>>GO TO 14.
EXCESSIVE RIPPLE, OPEN PHASE, OPEN DIODE or SHORTED DIODE>>Replace the generator. Refer
to CHG-29, "
Removal and Installation". Perform “DIODE RIPPLE” test again using Multitasking
battery and electrical diagnostic station GR8-1200 NI or Battery and electrical diagnostic analyzer
EXP-800 NI to confirm repair.
4.INSPECTION WITH CHARGE WARNING LAMP (IGNITION SWITCH IS ON)
Turn the ignition switch ON.
Does the charge warning lamp illuminate?
YES >> GO TO 6.
NO >> GO TO 5.
5.“L” TERMINAL CIRCUIT (OPEN) INSPECTION
Check “L” terminal circuit (open). Refer to CHG-24, "
Diagnosis Procedure".
Is the
“L” terminal circuit normal?
YES >> Replace generator. Refer to CHG-29, "Removal and Installation".
NO >> Repair as needed.
6.INSPECTION WITH CHARGE WARNING LAMP (IDLING)
Start the engine and run it at idle.
Does the charge warning lamp turn OFF?
YES >> GO TO 9.
NO >> GO TO 7.
7.“L” TERMINAL CIRCUIT (SHORT) INSPECTION
Check “L” terminal circuit (short). Refer to CHG-26, "
Diagnosis Procedure".
Is the
“L” terminal circuit normal?
YES >> GO TO 8.
NO >> Repair as needed.
8.“S” TERMINAL CIRCUIT INSPECTION
Check “S” terminal circuit. Refer to CHG-27, "
Diagnosis Procedure".
Is the
“S” terminal circuit normal?
YES >> GO TO 10.
Revision: August 2015 2016 Versa Note
cardiagn.com
CHG-18
< BASIC INSPECTION >
DIAGNOSIS AND REPAIR WORKFLOW
• Use fully charged battery.
DETAILED FLOW
1.PRELIMINARY INSPECTION
Perform the preliminary inspection. Refer to CHG-20, "
Diagnosis Procedure".
>> GO TO 2.
2.STOP POWER GENERATION VOLT AGE VARIABLE CONTROL SYSTEM
Stop the operation of the power generation voltage variabl e control in either of the following procedures:
• After selecting “ENGINE” using CONSULT, set the DUTY value of “ALTERNATOR DUTY” to 0 % by select-
ing “ALTERNATOR DUTY” with “Active Test”. Continue “Active Test” until the end of inspection. (When the
DUTY value is 0 or 100 %, the normal power generation is performed according to the characteristic of the
IC regulator of the generator.)
• Turn the ignition switch OFF, and disconnect the batte ry current sensor connector. [However, DTC (P1550 -
P1554) of the engine might remain. After finishing the inspection, connect the battery current sensor connec-
tor and erase the self-diagnostic results history of the engine using CONSULT.]
>> GO TO 3.
3.INSPECTION WITH CHARGE WARNING LAMP (IGNITION SWITCH IS TURNED ON)
When ignition switch is turned ON.
Does the charge warning lamp illuminate?
YES >> GO TO 4.
NO >> GO TO 10.
4.INSPECTION WITH CHARGE WARNING LAMP (IDLING)
Start the engine and run it at idle
Does the charge warning lamp turn OFF?
ALMIA0577GB
Revision: August 2015 2016 Versa Note
cardiagn.com
CHG
POWER GENERATION VOLTAGE VARIABLE CONTROL SYSTEM OPERATION
INSPECTION
CHG-21
< DTC/CIRCUIT DIAGNOSIS >
C
DE
F
G H
I
J
K L
B A
O P
N
POWER GENERATION VOLTAGE VARI
ABLE CONTROL SYSTEM OPER-
ATION INSPECTION
Diagnosis ProcedureINFOID:0000000012431250
Regarding Wiring Diagram information. Refer to CHG-9, "Wiring Diagram".
CAUTION:
When performing this inspection, always use a charged battery that has completed the battery inspec-
tion. (When the charging rate of the battery is low, the response speed of the voltage change will
become slow. This can cause an incorrect inspection.)
1.CHECK ECM (CONSULT)
Perform “Self Diagnostic Result” of “ECM” with CONSULT. Refer to EC-60, "
CONSULT Function".
Self
-diagnostic results content
No malfunction detected>> GO TO 2.
Malfunction detected>> Check applicable parts, and repair or replace corresponding parts.
2.CHECK OPERATION OF POWER GENERATION VOLTAGE VARIABLE CONTROL SYSTEM
1. Connect CONSULT and start the engine.
2. The selector lever is in “P” or “N” position and a ll of the electric loads and A/C, etc. are turned OFF.
3. Select “ALTERNATOR DUTY” in “Active Test” of “ENGINE”, and then check the value of “BATTERY
VOLT” monitor when DUTY value of “DUTY” is set to 40.0 %.
4. Check the value of “BATTERY VOLT” monitor when DUTY value of “DUTY” is set to 80.0%.
Is the inspection result normal?
YES >> Inspection End.
NO >> GO TO 3.
3.CHECK IPDM E/R (CONSULT)
Perform “Self Diagnostic Result” of “I PDM E/R” with CONSULT. Refer to PCS-10, "
CONSULT Function (IPDM
E/R)".
Is the inspection result normal?
No malfunction detected>> GO TO 4.
Malfunction detected>> Check applicable parts, and repair or replace corresponding parts.
4.CHECK HARNESS BETWEEN GE NERATOR AND IPDM E/R
1. Turn ignition switch OFF.
2. Disconnect generator connector and IPDM E/R connector.
3. Check continuity between generator harne ss connector and IPDM E/R harness connector.
“BATTERY VOLT”
2 seconds after setting the
DUTY value of “ALTERNA-
TOR DUTY” to 40.0 %
: 12 - 13.6 V
“BATTERY VOLT”
20 seconds after setting
the DUTY value of “ALTER-
NATOR DUTY” to 80.0 % : +0.5 V or more against
the value of “BATTERY
VOLT” monitor when
DUTY value is 40.0 %
Revision: August 2015
2016 Versa Note
cardiagn.com
EC-68
< SYSTEM DESCRIPTION >[HR16DE]
DIAGNOSIS SYSTEM (ECM)
*: Leaving cooling fan OFF with CONSULT while engine is running may cause the engine to overheat.TEST ITEM
CONDITION JUDGMENTCHECK ITEM (REMEDY)
FUEL INJECTION • Engine: Return to the original trouble
condition
• Change the amount of fuel injection
using CONSULT. If trouble symptom disappears, see
CHECK ITEM.
• Harness and connectors
• Fuel injector
• Air fuel ratio (A/F) sensor 1
ENG COOLANT
TEMP • Engine: Return to the original trouble
condition
• Change the engine coolant tempera-
ture using CONSULT. If trouble symptom disappears, see
CHECK ITEM.• Harness and connectors
• Engine coolant temperature
sensor
• Fuel injector
PURG VOL CONT/V • Engine: After warming up, run engine
at 1,500 rpm.
• Change the EVAP canister purge vol-
ume control solenoid valve opening
percent using CONSULT. Engine speed changes according to
the opening percent.
• Harness and connectors
• Solenoid valve
FUEL/T TEMP SEN Change the fuel tank temperature using CONSULT.
COOLING FAN* • Ignition switch: ON
• Turn the cooling fan “LOW”, “HI” and
“OFF” CONSULT. Cooling fan moves and stops.
• Harness and connectors
• IPDM E/R (Cooling fan relay)
• Cooling fan motor
ALTERNATOR
DUTY • Engine: Idle
• Change duty ratio using CONSULT.
Battery voltage changes.• Harness and connectors
• IPDM E/R
•Alternator
FUEL PUMP RELAY • Ignition switch: ON
• Turn the fuel pump relay “ON” and
“OFF” using CONSULT and listen to
operating sound. Fuel pump relay makes the operat-
ing sound.
• Harness and connectors
•Fuel pump relay
IGNITION TIMING • Engine: Return to the original trouble
condition
• Timing light: Set
• Retard the ignition timing using CON- SULT. If trouble symptom disappears, see
CHECK ITEM.
Perform Idle Air Volume Learn-
ing.
POWER BALANCE • Engine: After warming up, idle the en-
gine.
• A/C switch OFF
• Shift lever: P or N (CVT), Neutral (M/
T)
• Cut off each fuel injector signal one at
a time using CONSULT. Engine runs rough or dies.
• Harness and connectors
• Compression
• Fuel injector
• Power transistor
• Spark plug
• Ignition coil
VENT CONTROL/V • Ignition switch: ON
• Turn solenoid valve ON and OFF with
the CONSULT and listen to operating
sound. Solenoid valve makes an operating
sound.
• Harness and connectors
• EVAP canister vent control
solenoid valve
INT V/T ASSIGN
ANGLE • Engine: Return to the original non-
standard condition
• Change intake valve timing using CONSULT. If malfunctioning symptom disap-
pears, see CHECK ITEM.
• Harness and connectors
• Intake valve timing control
solenoid valve
EX H V/T ASSIGN
ANGLE •
E
ngine: Return to the original non-
standard condition
• Change exhaust valve timing using CONSULT. If malfunctioning symptom disap-
pears, see CHECK ITEM.
• Harness and connectors
• Exhaust valve timing control
solenoid valve
ACTIVE GRILLE
SHUTTER NOTE:
Initial position learning is required every
time when the ignition switch is turned
OFF.
1. Engine: Idle speed
2. Touch “CALIBRTN” to perform ini-
tial position learning.
3. Touch “OPEN” or “CLOSE” to op- erate active grille shutter. Active grille shutter fully opens or
fully closes.
• Harness or connector
• Active grille shutter actuator
• Active grille shutter
Revision: August 2015
2016 Versa Note