Page 525 of 796

08-138610-11
4. FUNCTIONS OF RAIN SENSOR
1) Windshield Glass and Coupler Attachment
Check the outer windshield surface of sensing area for wear, damage and scratch. The sensor is able
to compensate the wear up to a specific level. Check the coupler attached surface of windshield for
porosity. If the porosity exists, the sensor cannot function properly.
2) Recognition of AUTO Mode
3) Instant Wipe Function
When the variable resistance knob on the multifunction wiper switch is turned by each 1 stage from
low sensitivity (S mark) to high sensitivity (F mark), the wiper operates one cycle.
And, the wiper also operates during raining up to 5 minutes after rain stops.When the engine is started with the wiper switch “AUTO” position, the wiper operates one
cycle to remind a driver that the wiper switch is in “AUTO” position.
When the wi
per switch is turned to “AUTO” from OFF, the wiper operates one cycle. It always
operates one cycle for the initial operation, however, the wiper does not operate afterwards to
prevent the wiper blade wear if not raining when turning the wiper switch to “AUTO” from
“OFF”. However, the wiper operates up to 5 minutes after rain stops.
If this function does not occur, check No. 2 terminal on the rain sensor. If any defective cannot be
found, check the wiper relay (LOW) for defective. 1.
2.
3.If the installed wiper brushes are out of specification (size and length), the rain sensing area
cannot be fully wiped. In this case, the rain sensor’s sensitivity could be decreased and
the wipers are not properly operated. - The followings are the detailed description of the functions and operations of the rain sensing wiper
control.
As described, the STICS recognizes the wiper switch “AUTO” position. If there are not any
problem, go to diagnosis mode in STICS and check the terminal that receives signal from wiper
and communication lines between rain sensor unit and STICS. -
When the variable resistance knob is rotated by 4 stage from 0 stage without stopping, the wiper
operates one cycle. The wiper operates one cycle when changing the wiping stage (0 →
1, 1 → 2, 2 → 3). -
Page 526 of 796

08-14
4) Washer Coupled Wiper Function
Check the washer coupled wiper operation by pressing the washer switch.
5) Irregular Operations (Abrupt Operations)
6) Self Diagnosis
Position the wiper switch to “AUTO” position and rotate the variable resistance knob from
“FAST” toward “SLOW” by one step.
At this moment, check if the wiper operates one cycle.
The wiper operates when the windshield glass is excessively worn or scratched, the windshield glass is
not cleared wiped due to using worn wiper blade or different wiper blade, or the rain sensor is not
improperly installed.Check the sensor for coming off.
Check the rain sensor cover installation.
Check that the customer is familiar to how to control the wiper sensitivity. -
-
-
If the wiper blade cannot wipe the glass uniformly and clearly, the irregular operations could be
occurred. And, the wiper blade should be replaced with new one with same specifications. Check that the customer can select the sensitivity by selecting the variable resistance value (stage 1 to
stage 5), that is, the wiper sensitivity control value. And, also check whether the sensitivity is selected
to the highest value of FAST (stage 5).
Check the wiper blade for wear. -
▶Poor sensing
▶Poor sensor
Rotate the variable resistance knob toward “SLOW” by 2 more steps. At this moment, check if
the wiper operates one cycle.
The wiper operates when the sensor is defective.
Page 530 of 796
09-38790-01
1. SPECIFICATIONS FOR PAS
Item Item Specification
PAS unitRated voltageDC 13.6 V
(IGN power)
Operating voltage DC 9.0 V ~ 16.0 V
Operating temperature-30℃ ~ +80℃
Maximum humidity 95%
High internal pressure 24 V
Insulation resistance No heat & fire due to current leak
Max. permissible currentUnit: 100 mA or less
Sensor: 35 mA or less
PAS sensorOperating frequency 58 KHz
Detection range30 cm~120 cm
(based on lineal distance between sensor
and obstacle)
Tolerance± 10 cm
Operating voltage range DC 8 V
Page 540 of 796
11-38910-05
1. SPECIFICATION
1) Audio Head Unit
Item Specification
Audio Voltage DC 14.4V
Operating voltage DC 10.8V~16.0V
Output 45W/1ch 4ch
Current consumption 5 A or less Up to 10 A
Leakage current 3 mA or less
Radio Frequency FM: 87.5~108MHz
AM: 531~1602KHz
MW: 522~1620KHZ
LW: 144~290KHZ
Preset FM1: 6ch
FM2: 6ch
AM: 6ch
MW : 6ch
LW : 6ch
Usable sensitivity AM: 25dBu
FM: 10dBu
S/N raito (limit value) AM: 54dB
FM: 60dB
LCD Type FSTN
Operating voltage 9.0V VDD: 3.0~3.3V
Operating temperature-30℃ ~ +80℃
Operating temperature-40℃ ~ +85℃
Size (W x H) 132X36
Bluetooth Component MD-5XR (Bluetooth multimedia module)
Application technologyBluetooth 2.0+EDR (Enhanced Data Rate)
Specification Supports HFP, A2DP, AVRCP profile formats
(HFP, A2DP: profile for calling)
(AVRCP: profile for listening music)
Page 541 of 796
11-4
2) Micro Pole Antenna
3) Speaker
Item Specification
Front tweeter speakerSpeaker size 42 mm
Max. input 25 W
Impedance5 KHz of 4Ω ±15%
Front door speakerSpeaker size 6.5 inch
Max. input 40 W
Impedance400 Hz of 4Ω ±15%
Quarter speakerSpeaker size 171X241 mm, 6X9 inch
Max. input 40 W
Impedance300 Hz of 4Ω ±15%
Item Specification
Operating current Max. 150 mA
Operating voltage DC 10.5 V ~ 16 V
Operating temperature-30℃ ~ +60℃
Storage temperature-40℃ ~ +80℃
I/O impedance75Ω (FM)
4) Handsfree microphone
Item Specification
Storage temperature-30 ~ 80℃
Operating temperature-40 ~ 85℃
Sensitivity-35 ± 2 dB
ImpedanceUp to 2.2 ㏀
S/N ratio* 60dB or higher
S/N ratio (signal to noise ratio): Describes noise level in relation to the signal level in dB *
Page 543 of 796
11-6
Radio antenna specification changed
Changed to micro pole antenna from glass antenna (with radio antenna amplifier)
Page 554 of 796
01-33650-01
Diameter( Torque converter) 270 mm
Lockup function Yes
Gear ratios 1st 3.595
2nd 2.186
3rd 1.405
4th 1.000
5th 0.831
Reverse:
S mode / W mode3.167/1.926
Driving type 2WD(4WD)
Fluid specification Shell ATF 134
Fluid capacityapprox. 8 ℓ
Selected lever
indicationP.R.N.D Mechanical
D+/D- Electrical
Parking lock systemBrake switch(signal) → TGS lever
Reverse lock systemCAN → TGS lever
Selected lever
indicationP.R.N.D Lever position
1, 2, 3, 4, 5 CAN
Oil temperature
sensorResistance: R, D0.5 ~ 2.5 kΩ
Resistance: P, N20 kΩ
TCU EGS 52
Shift solenoid
valve(25℃)Resistance3.8 ± 0.2 Ω
Operating distance 0.2 mm
Operating current 1.5 ~ 2 A
Item Specification
Input torque 450 Nm
1. SPECIFICATIONS
W5A580(2WD) / W5A400(4WD) ▶
Page 555 of 796
01-4
Item W5A330(300) W5A580(400)
M/P, S/P solenoid
valve(23℃)Resistance5.0 ± 0.2 Ω
Operating distance 0.6 mm
Operating current 0 ~ 1 A
Lockup solenoid
valve(25℃)Resistance2.5 ± 0.2 Ω
Operating distance 0.2 mm
Operating current 1.5 ~ 2.0 A
Operating range 3rd to 5th gears
Speed sensor Resistance HALL type
Operating voltage 6 V
Start lockout switch Switch contact ON(D position)
Switch contact OFF(P, N position)
Mode switch W(Winter)
S(Standard)
One-way clutch F1, F2
Planetary gear set Plain planetary gear:
3(number of pinion)3, 4, 3 4, 4, 4
Disc clutch Disc: C2*, C2, C3* Single plate type*
Disc brake Disc: B1*, B2, B3 Single plate type*
Item Specification