2013 SSANGYONG TURISMO Specification

[x] Cancel search: Specification

Page 630 of 796

SSANGYONG TURISMO 2013  Service Manual 08-34850-03
Brake oil Grade DOT 4
Service interval Replace every 2 years
1. SPECIFICATIONS
Description Specification
Front brake Type Ventilated disc
Rear brake Type Ventilated disc
Master cylinder Ty

Page 649 of 796

SSANGYONG TURISMO 2013  Service Manual 09-34891-01
1. SPECIFICATIONS
1) Pressure Sensor
UnitDescription
Location
ABS ESP
HECU
(Hydraulic & 
Electronic Control 
Unit) CPU:MCU60 (32bit)
Clock Frequency: 
28 MHz
Memory: 128~256 KB CPU:MCU60 (

Page 650 of 796

SSANGYONG TURISMO 2013  Service Manual 09-4
2) Sensor Cluster
3) Steering Wheel Angle Sensor
Air gap between sensor and rotorFront 0.3 ~ 1.3 mm
Rear 0.3 ~ 1.3 mm
Current (at 2.75 km/h)IHIGH  :  14 mA  
ILOW  :  7 mA 
Voltage (when turning

Page 685 of 796

SSANGYONG TURISMO 2013  Service Manual 11-34610-00
1. SPECIFICATIONS
Description Specification
Steering wheelType 4-spoke type
Outer diameter (mm) 390 
Steering gear boxType Rack and pinion type
Steering angleInner36.4° 
Outer31.5° 
Stee

Page 698 of 796

SSANGYONG TURISMO 2013  Service Manual 12-34170-01
1. SPECIFICATION
Description Specification
Tire 16 inch 225/65R16
17 inch 235/60R17
Tire inflation pressure 35 psi
Wheel 16 inch 6.5JX16
17 inch 7.0JX17
Balance weight Inner: Clip-on type

Page 699 of 796

SSANGYONG TURISMO 2013  Service Manual 12-4
Spare Tire & Winch Assembly
- Spare tire specification added (same as one fitted to vehicle with standard wheel and tire) 
Wheel assembly
16 inch (6.5JX16) 17 inch (7.0JX17)
2WD 4WD 2WD 4WD
225/6

Page 708 of 796

SSANGYONG TURISMO 2013  Service Manual 01-36810-30
1. SPECIFICATION
Item FATC Manual
A/C controllerRated voltage DC 12 V DC 12 V
Operating voltage DC 9 to 16 V DC 9 to 16 V
Current consumption 2 A 2.5 A
Operating temperature-30~75℃ -30~8

Page 731 of 796

SSANGYONG TURISMO 2013  Service Manual 02-38810-03
1. SPECIFICATIONS
Description Item Specification
Air bag unit
(SDM)Operating voltage 10.0 V to 16.5 V
Voltage for diagnosis and self-
diagnosis8.0 V to 16.5 V
Operating temperature-40℃ ~