Page 279 of 796
09-31451-01
1. SPECIFICATION
AlternatorCrankshaft pulley : Alternator pulley 1 : 2.94
Normal output (idling/2200 rpm) 70/140A
Regulator voltage 14.6 V
BrushLength 12.5mm
Wear limit 7mm
BatteryType MF
Capacity 90 AH
Unit Description Specification
Page 280 of 796

09-4
2. INSPECTION
1) Alternator Output Test
Item How to check DTC set value / Action
Output
current
B terminal
current
Rotor
coil
resistance
D terminal
voltage
Disconnect the cable connected to the B
terminal on the alternator. Connect one
end of the ammeter to the B terminal and
the other end to the cable connected to
the B terminal.
Measure the maximum output value.
(Maintain the engine speed between
2,500 and 3,000 rpm.)
(Turn the headlamp and all the electrical
switches on.) 1.
2.Pass: If the measured current is 45
A or higher.
Fail: If the measured current is less
than 45 A.
Check the current of the B
terminal. -
-
-
Move the gear selector lever to the neutral
position.
Maintain the engine speed at 2,500 rpm
with the vehicle unloaded.
(Turn all the electrical switches off.) 1.
2.Open circuit: If the measured
current is 5 A or higher. -
Disconnect the negative cable from the
battery.
Remove the B terminal and turn off the
ignition switch.
Measure the resistance between the L and
F terminals with an ohmmeter. 1.
2.
3.Pass: If the measured resistance is
between 3 and 6 Ω.
Faulty rotor coil or slip ring: If the
measured resistance is less than 3
Ω or greater than 6 Ω. -
-
Connect the B terminal wiring.
Measure the voltage with the engine
running. 1.
2.Specification: 12.5 V to 14.5 V
Faulty IC regulator or field coil: If
the measured voltage is 14.5 V or
higher. -
-
Disconnect the negative battery cable.
Connect the negative cable again after connecting the ammeter. -
-
Page 288 of 796

09-12
Alternator (115 A)
2) Charging
The alternator uses a new regulator which has three diodes. It consists of the delta stator, rectifier
bridge, slip ring and brush.
Charging time according to vehicle conditions and environment ▶
Specification: Charging a fully depleted high-
capacity battery takes twice or more as long as
charging a fully depleted battery for small
vehicles.
Temperature:The lower the temperature is, the
longer the time taken to charge the battery.
When connecting the battery charger to the cold
battery, the amount of current the battery can
accept initially is very small. As the battery gets
warmer, it can accept more current.
Charging capacity: Charging a battery with a low-capacity charger takes longer time than charging
with a high-capacity charger.
Charging status: Charging a fully depleted battery takes twice or more as long as charging a half-
depleted battery. Since the electrolyte in a fully depleted battery consists of nearly pure water and
conductor, only a very small amount of current can be accepted by the battery initially. The charging
current increases as the amount of acids in the electrolyte is increased by the charging current.
3) Output Characteristics
Alternator (140 A)
Page 290 of 796
10-31413-00
1. SPECIFICATIONS
Description Specification
Glow plug Rated voltage 4.4 V
Max. temperature1100 °C
Operating temperature1080 °C ~ 1000 °C
Resistance23 °C: 0.39 ~ 0.52Ω
Glow plug control unit Operating voltage 6 ~ 16 V
Operating temperature-40°C ~ 110°C
Dark current Max. 1 mA
Page 298 of 796
11-31461-01
1. SPECIFICATION
Description Specification
Capacity 12V 2.3kW
Engagement Meshed type
Rotating direction Clockwise
Pinion gear manufacturing Cooled forging
Solenoid operating voltage Max. 8 V
Weight 2.5 kg
Bracket manufacturing Aluminum die casting
Page 310 of 796
13-31793-00
1. SPECIFICATION
Item Specification
E-EGR valve Motor EGR response time 50 ms
Driven by DC motor
Valve EGR gas flow rate 120 Kg/h
Position sensor Sensing type Hole sensor
Supplied voltage5V ± 10%
Maximum signal
range5% ~ 95%
Maximum power
consumption<15mA
E-EGR cooler Cooling capacity 8.3 kW or more
Cooling fin type Wavy fin
Cooler type U-shaped
E-EGR bypass valve Driven by Vacuum
(Solenoid valve)
Page 383 of 796
02-31113-01
1. SPECIFICATIONS
1) Engine Specifications
Page 386 of 796
02-6
3. FASTENER TIGHTENING SPECIFICATIONS