2012 SSANGYONG RODIUS battery

[x] Cancel search: battery

Page 148 of 715

SSANGYONG RODIUS 2012  Service Manual 01-6
3. ENGINE COMPARTMENT LAYOUT
Do not work on the engine compartment while the engine, radiator, exhaust manifold, muffler 
or catalytic converter is hot. Always turn the engine off and allow it to

Page 151 of 715

SSANGYONG RODIUS 2012  Service Manual 01-90000-00
4. CAUTION WHEN SERVICING THE ENGINE
1) Cleaness
Engine has a lot of precisely machined (grinding, polishing, lapping) surfaces. Thus, there should 
be great cautions for cleaness when ser

Page 168 of 715

SSANGYONG RODIUS 2012  Service Manual 02-110000-00
4. GUIDELINES ON ENGINE SERVICE
To prevent personal injuries and vehicle damages that can be caused by mistakes during engine 
and unit inspection/repair and to secure optimum engine perf

Page 169 of 715

SSANGYONG RODIUS 2012  Service Manual 02-12
Electrical equipment ▶
Electric devices should be handled more carefully.
Currently, the engine has a lot of electric devices. there could be poor engine performance, 
incomplete combustion an

Page 209 of 715

SSANGYONG RODIUS 2012  Service Manual 03-52210-01
Plug the removed components with clean and undamaged sealing caps and store it into the 
box to keep the conditions when it was installed. 6.
Fuel filter assembly
Follow the job procedures

Page 275 of 715

SSANGYONG RODIUS 2012  Service Manual 09-31451-01
1. SPECIFICATION
AlternatorCrankshaft pulley : Alternator pulley 1 : 2.94 
Normal output (idling/2200 rpm) 70/140A 
Regulator voltage 14.6 V 
BrushLength 12.5mm 
Wear limit 7mm 
BatteryTyp

Page 276 of 715

SSANGYONG RODIUS 2012  Service Manual 09-4
2. INSPECTION
1) Alternator Output Test
Item How to check DTC set value / Action
Output 
current
B terminal 
current
Rotor 
coil 
resistance
D terminal 
voltage 
Disconnect the cable connected to

Page 277 of 715

SSANGYONG RODIUS 2012  Service Manual 09-51451-01
2) Troubleshooting for Alternator
Item Cause Action
Overcharged 
batteryDefective alternator voltage regulator Replace the alternator
Defective voltage detection wiring Replace the alterna