2012 SSANGYONG RODIUS battery

[x] Cancel search: battery

Page 278 of 715

SSANGYONG RODIUS 2012  Service Manual 09-6
3) Checking Battery

Page 279 of 715

SSANGYONG RODIUS 2012  Service Manual 09-71451-01
(1) Checking
Using battery tester ▶
PASS (11.0 V or more): Explain to the customer that the battery is reusable.
Need to be charged (9.0 to 11.0 V): Charge the battery with a charger and

Page 280 of 715

SSANGYONG RODIUS 2012  Service Manual 09-8
(3) Starting with jumper cable
If the battery is weak or terminated, the battery from another vehicle can be used with jumper
cables to start the engine.
Connecting order ▶
The positive (+) ter

Page 281 of 715

SSANGYONG RODIUS 2012  Service Manual 09-91451-01
(4) Maintenance
If the charge warning lamp (        ) on the instrument cluster comes on while driving, there is a 
malfunction in the charge system including the battery. Therefore, carry

Page 282 of 715

SSANGYONG RODIUS 2012  Service Manual 09-10
Alternator
The alternator charges the battery and 
supplies power to each electric unit by 
converting the mechanical energy to the 
electrical energy.
1. SYSTEM DESCRIPTION
1) Overview
The char

Page 284 of 715

SSANGYONG RODIUS 2012  Service Manual 09-12
Alternator (115 A)
2) Charging
The alternator uses a new regulator which has three diodes. It consists of the delta stator, rectifier 
bridge, slip ring and brush.
Charging time according to veh

Page 290 of 715

SSANGYONG RODIUS 2012  Service Manual 10-71413-00
4) Operation
Glow plug is installed in the cylinder head. It enhances the cold starting performance and reduces 
the exhaust gas during cold starting.
ECU receives the data (engine rpm, co

Page 291 of 715

SSANGYONG RODIUS 2012  Service Manual 10-8
(2) Pre-heating time control based on battery voltage
GCU monitors the battery voltage. If it is low, GCU extends the pre-heating time.
GCU monitors the energy to glow plugs (the amount of pre-he