Page 317 of 442

5-22 Comfort controls
5
To listen to the radio
N00735000913
1. Press the POWER button until it beeps to turn the audio
system ON and OFF. The system turns on in the last mode
used.
Press the RADIO button to turn ON the radio.
2. Press the RADIO button to select the desired band
(AM/FM1/FM2).
3. Press the SEEK button to tune to a station, or press the
MEMORY button either or to tune in to a station
memorized.
Refer to “Automatic tuning”, “Manual tuning” or “To
enter frequencies into the memory”.Automatic tuningAfter pressing the SEEK button, a receivable station will be
automatically selected and reception of the station will begin.
SCAN function
Press the SCAN button. The radio will tune consecutively to
each available station for about 5 seconds per station. If you
want to stop scanning, press the SCAN button again.
The frequency display of the current station flashes once per
second during SCAN.Manual tuningThe frequency changes every time the SEEK button is pressed.
Press the button to select the desired station.To enter frequencies into the memoryAs many as 6 AM and 12 FM stations can be entered into the
memory.To store a frequency in the memory, follow these steps:
1. Press the SEEK button to tune to the frequency you wish
to keep in the memory.
2. Press the MEMORY button either or until it beeps.
The sound will be momentarily interrupted while the fre-
quency is being entered into the memory.
3. To recall a frequency that has been saved in memory,
press the MEMORY button briefly for no longer than
about 1 second.
NOTEDisconnecting the 12V starter battery cables erases all the
radio station settings stored in the memory.
BK0140800US.book 22 ページ 2011年9月29日 木曜日 午後3時28分
Page 336 of 442

Comfort controls
5-41
5 Clock
(if so equipped)
N00755000124
The time is displayed when the electric motor switch is in the
“ON” or “ACC” position.To set the time1. Press and hold the clock button and the clock display
flashes.
2. Press the SEEK button to adjust the “hours” digit.
If you keep pressing the button, fast-forward begins.3. When the “hours” digit is adjusted, press the clock button
to flash the “minutes” digit.
Press the SEEK button to adjust the “minutes” digit.
If you keep pressing the button, fast-forward begins.
4. When the time is set, press the clock button to stop the
clock display from flashing.
NOTEReset the time after the 12V starter battery terminals are
disconnected and reconnected.
Seconds do not appear in the clock display, but after
adjusting the “minutes” setting, the clock begins to oper-
ate from 0 seconds.
A- Clock button
B- SEEK (clock adjustment up) button
C- SEEK (clock adjustment down) button
BK0140800US.book 41 ページ 2011年9月29日 木曜日 午後3時28分
Page 341 of 442

6-2 For emergencies
6If the vehicle breaks down
N00836300220
If your vehicle breaks down on the road, move to the shoulder
and turn on the hazard warning flashers. If there is no shoulder,
or the shoulder is not safe, drive in the right lane slowly, with
the hazard lights flashing, until you come to a safe stopping
place. Keep the flashers flashing.
If the ready indicator light goes out while driving, the brakes
and steering will continue to work, but without power assist, so
more effort will be required for braking and steering. Stop the
vehicle on the shoulder of the road and turn on the hazard
warning flashers.
Jump-starting
N00836400739
If the electric motor unit cannot be energized because the 12V
starter battery is weak or dead, you can start it with the battery
from another vehicle using jumper cables. NOTEDo not use jumper cables if they have damage or corro-
sion.
1. Take off any metal jewelry such as watch bands or brace-
lets that might make an accidental electrical contact.
WA R N I N G
!To reduce the risk of igniting flammable gas that
may be emitted from the 12V starter battery, care-
fully read this section before jump-starting the vehi-
cle.Do not try to start the electric motor unit by pushing
or towing the vehicle. This can cause an accident
resulting in serious injury or death and can damage
the vehicle.
CAUTION
!Do not attempt jump starting the 12V starter bat-
tery while the main drive lithium-ion battery is
being charged. Doing so could damage the vehicle or
charging equipment.
BK0140800US.book 2 ページ 2011年9月29日 木曜日 午後3時28分
Page 342 of 442

For emergencies
6-3
6
2. Position the vehicles close enough together so that the
jumper cables can reach, but be sure the vehicles are not
touching each other.
3. Set the parking brake firmly on your vehicle and move the
selector lever into the “P” (PARK) position.
4. Set the parking brake firmly on the other vehicle. Put the
automatic transaxle in “P” (PARK) or the manual
transaxle in “N” (Neutral).
5. Turn the ignition switch (the electric motor switch) on
each vehicle to the “LOCK” position.NOTETurn off all lights, heater, and other electrical loads. This
will help avoid sparks.6. Remove the battery cover, and then make sure your 12V
starter battery electrolyte is at the proper level. (Refer to
“Checking 12V starter battery electrolyte level” on page
7-14.)
7. Connect one end of one jumper cable to the positive
(+) terminal of the discharged battery (A), and then con-
nect the other end to the positive (+) terminal of the
booster battery (B).
CAUTION
!Check the other vehicle. It must have a 12V battery.
If the other system is not 12V, both systems can be
damaged.
WA R N I N G
!If the electrolyte fluid is not visible, or looks frozen,
DO NOT ATTEMPT JUMP STARTING!!
The battery might split open or explode if the tem-
perature is below the freezing point or if it is not
filled to the proper level.
BK0140800US.book 3 ページ 2011年9月29日 木曜日 午後3時28分
Page 343 of 442

6-4 For emergencies
6
NOTEOpen the terminal cover before connecting the jumper
cable to the positive terminal of the 12V starter battery.
(Refer to “Disconnection and connection” on page 7-16.)
Use the proper cables suitable for the battery size.
Otherwise heat damage to the cables could result.8. Connect one end of the other jumper cable to the nega-
tive (-) terminal of the booster battery (B), and then con-
nect the other end to the designated ground location of
the vehicle with the discharged battery (A) at the point
farthest from the battery.
9. Start the engine in the vehicle providing the boost. Let the
engine idle a few minutes, then start the electric motor
unit by turning the electric motor switch to the ON posi-
tion.
WA R N I N G
!Make sure that the jumper cables and your clothing
are clear of the cooling fans and drive belts. Entan-
glement with the fans or belts can cause serious per-
sonal injury.
WA R N I N G
!Be sure to follow the proper order when connecting
the batteries, of: →→→.Make sure that the connection is made to the cor-
rect designated location (as shown in the illustra-
tion) properly. If the connection is directly made to
the negative (-) terminal of the battery, the flamma-
ble gases from inside the battery might catch fire
and explode, causing personal injury. When connecting the jumper cables, do not connect
the positive (+) cable to the negative (-) terminal.
Sparks can make the battery explode.
BK0140800US.book 4 ページ 2011年9月29日 木曜日 午後3時28分
Page 344 of 442
![MITSUBISHI iMiEV 2012 1.G Owners Manual For emergencies
6-5
6
10. Check if the ready indicator illuminates.
[When the ready indicator illuminates]
Stop the engine of the other vehicle, and disconnect the
cables in the reverse order and keep MITSUBISHI iMiEV 2012 1.G Owners Manual For emergencies
6-5
6
10. Check if the ready indicator illuminates.
[When the ready indicator illuminates]
Stop the engine of the other vehicle, and disconnect the
cables in the reverse order and keep](/manual-img/19/7553/w960_7553-343.png)
For emergencies
6-5
6
10. Check if the ready indicator illuminates.
[When the ready indicator illuminates]
Stop the engine of the other vehicle, and disconnect the
cables in the reverse order and keep the electric motor
switch in the ON position to charge the 12V starter battery
for more than 30 minutes.
After the 12V starter battery is charged, continue the pro-
cess from step 15.
[When the ready indicator does not illuminate]
Both the 12V starter battery and the main drive lithium-
ion battery have gone flat at the same time.
Charge the 12V starter battery and the main drive lithium-
ion battery by following steps from steps 11 to 13.
11. Keep the jumper cables to each vehicle connected and
turn the electric motor switch of your vehicle to the
“LOCK” position.NOTEThe jumper cables need to be connected to the 12V starter
battery when you start charging the main drive lithium-ion
battery because the on board charger etc. operate utilizing
power from the 12V starter battery.
12. Charge the main drive lithium-ion battery by regular
charging. The 12V starter battery is automatically charged
while charging the main drive lithium-ion battery. (Refer
to “Regular charging” on page 1-20.)13. When the charging indicator on the instrument cluster is
illuminated, stop the engine of the other vehicle and dis-
connect the jumper cables in the reverse order.
NOTEWhen the regular charge connector is connected to the
charge port, the charging indicator will blink. When
charging has started, the charging indicator will illumi-
nate.
The 12V starter battery will automatically charge while
the main drive lithium-ion battery is charging.
14. Charge the main drive lithium-ion battery for more than 1
hour.
15. Disconnect the charging cable.
(Refer to “Regular charging” on page 1-20.)
BK0140800US.book 5 ページ 2011年9月29日 木曜日 午後3時28分
Page 345 of 442

6-6 For emergencies
6
16. Turn the electric motor switch to the “START” position,
make sure that the ready indicator on the instrument clus-
ter is illuminated.
If the ready indicator does not illuminate, perform the pro-
cedure again starting from step 5. If charging cannot be
performed, consult a certified i-MiEV dealer.
17. Refit the battery cover. (“Checking 12V starter battery
electrolyte level” on page 7-14.)
Charging the 12V starter battery by using an
external battery charger
WA R N I N G
!Always remove the 12V starter battery from your
vehicle when the 12V starter batter is charged by an
external battery charger.Keep sparks, cigarettes and flames away from the
12V starter battery because the battery may
explode.Keep your work area well vented when charging or
using the 12V starter battery in an enclosed space. Remove all the caps before charging the 12V starter
battery. Electrolyte (battery acid) is corrosive diluted sul-
phuric acid. If electrolyte comes in contact with your
hands, eyes, clothes, or the painted surface of your
vehicle, thoroughly flush with water. If electrolyte
gets in your eyes, flush them immediately and thor-
oughly with water, and get prompt medical atten-
tion.Always wear protective clothing and goggles when
working near the battery.Keep the battery out of the reach of children.
BK0140800US.book 6 ページ 2011年9月29日 木曜日 午後3時28分
Page 346 of 442

For emergencies
6-7
6
As your vehicle has anti-lock brakesIf you drive your vehicle with a low battery charge, after the
electric motor unit has been started by using jumper cables, it
can cause the anti-lock braking system warning light to illumi-
nate. This is only due to the low battery voltage. It is not a
problem with the brake system. If this happens, fully charge the
12V starter battery and ensure the charging system is operating
properly.
Tire repair kit
N00836600366
This vehicle is equipped with a tire repair kit which can be
used to repair a minor puncture in tread area caused by a nail,
screw or similar object. A spare tire is not provided with this
vehicle.
WA R N I N G
!The tire repair kit may not permanently seal a punc-
tured tire. Using the tire repair kit may damage the wheel
and/or the tire inflation pressure sensor for the tire.
The vehicle must promptly be inspected and
repaired by a certified i-MiEV dealer after using the
tire repair kit.Use only the Mitsubishi genuine tire repair kit. Seal-
ant in other repair kits may not sufficiently seal the
tire puncture.
BK0140800US.book 7 ページ 2011年9月29日 木曜日 午後3時28分