13B-191
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$104.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF891
CONTINUED
Check the condition of the injector connectors (see Wiring Diagram Technical Note, Mégane II ph2, Scénic II
ph2, Component codes 193, 194, 195, 196).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the continuity and insulation of the following connections:
– Connection code 3KW between components 193 and 120.
– Connection code 3CR between components 193 and 120.
– Connection code 3KX between components 194 and 120.
– Connection code 3CS between components 194 and 120.
– Connection code 3KY between components 195 and 120.
– Connection code 3CT between components 195 and 120.
– Connection code 3KZ between components 196 and 120.
– Connection code 3CU between components 196 and 120.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-192
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$104.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF892
PRESENT
OR
STOREDGROUP 2 INJECTORS FEED
1.DEF: Faulty connections
2.DEF: Short-circuit on earth or short-circuit on +12 V
NOTESConditions for applying the fault finding procedure to a stored fault:
If the fault becomes present after:
– the ignition is switched on,
– the engine is started.
Priority when dealing with a number of faults:
Deal with faults DF026 Cylinder 1 injector control circuit, DF027 Cylinder 2
injector control circuit, DF028 Cylinder 3 injector control circuit and DF029
Cylinder 4 injector control circuit first if they are present or stored.
Special notes:
If the fault is present:
–the level 2 injection warning light is illuminated,
– the engine stops.
Use bornier Elé. 1681 for any operations on the connectors of the engine management
computer.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
EDC16C36_V44_DF892/EDC16C36_V4C_DF892/EDC16C36_V48_DF892/EDC16C36_V50_DF892/EDC16C36_V54_DF892/
EDC16C36_V58_DF892EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-193
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$104.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF892
CONTINUED
Check the condition of the injector connectors (see Wiring Diagram Technical Note, Vehicle, Component
codes 193, 194, 195, 196).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the continuity and insulation of the following connections:
– Connection code 3KW between components 193 and 120.
– Connection code 3CR between components 193 and 120.
– Connection code 3KX between components 194 and 120.
– Connection code 3CS between components 194 and 120.
– Connection code 3KY between components 195 and 120.
– Connection code 3CT between components 195 and 120.
– Connection code 3KZ between components 196 and 120.
– Connection code 3CU between components 196 and 120.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-195
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$104.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
* diff: differential
DF953
PRESENT
OR
STOREDPARTICLE FILTER ABSENT
NOTESConditions for applying fault finding procedures to stored faults:
The fault is declared present after the engine is started or following a road test.
Special notes:
If the fault is present:
– particle filter regeneration is inhibited,
– blue/white smoke and black particles coming from the exhaust,
the OBD warning light will illuminate after three consecutive driving cycles (start + 5
seconds, switch off the ignition and wait 40 seconds).
Priorities when dealing with a number of faults:
– DF315 Particle filter diff.* pressure sensor if present or stored
IMPORTANT
In the long term, this fault may lead to premature wear and a greater risk of
turbocharger failure.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
EDC16C36_V48_DF953/EDC16C36_V50_DF953/EDC16C36_V58_DF953EDC16 C36
Program No.: 91
Vdiag No.: 48, 50, 58
13B-197
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$104.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF967
PRESENT
OR
STOREDRICHNESS RATIO SENSOR CIRCUITCC.0: Short circuit to earth
CC.1: Short-circuit on +12 volts.
CO: Open circuit
1.DEF: Abnormal voltage
2.DEF: Below minimum threshold
3.DEF: Above maximum threshold
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the ignition is switched on,
– a road test.
Special notes:
Use the bornier Elé. 1681 for all operations on the connectors of the injection
computer.
The richness ratio sensor is only present on certain F9Q818 engines. Check that the
vehicle is correctly equipped with this sensor.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
Check the condition of the connector of the richness ratio sensor (see Wiring Diagram Technical Note, Mégane
II ph2, Scénic II ph2, Component code 1587).
Check the condition of the connector of the engine management computer (see Wiring Diagram Technical Note,
Mégane II ph2, Scénic II ph2, Component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the continuity, insulation and absence of interference resistance on the following connections:
– Connection code 3AAS between components 1587 and 120.
– Connection code 3AAT between components 1587 and 120.
– Connection code 3AAU between components 1587 and 120.
– Connection code 3AAV between components 1587 and 120.
– Connection code 3AAW between components 1587 and 120.
Check for + 12 V on the connector of the richness ratio sensor.
– Connection code 3FB of component 1587.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
EDC16C36_V44_DF967/EDC16C36_V4C_DF967/EDC16C36_V48_DF967EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48
13B-198
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$104.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF970
PRESENT
OR
STOREDRICHNESS RATIO SENSOR HEATING CIRCUITCC.0: Short circuit to earth
CC.1: Short-circuit on +12 volts.
CO: Open circuit
1.DEF: Internal electrical fault
2.DEF: Below minimum threshold
3.DEF: Above maximum threshold
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the ignition is switched on,
– a road test,
– the relay is actuated by command AC231 Richness ratio sensor heating.
Special notes:
Use the bornier Elé. 1681 for all operations on the connectors of the injection
computer.
The richness ratio sensor is only present on certain F9Q818 engines. Check that the
vehicle is correctly equipped with this sensor.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
EDC16C36_V44_DF970/EDC16C36_V4C_DF970/EDC16C36_V48_DF970EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48
13B-199
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$104.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF970
CONTINUED
Check the condition of the connector of the richness ratio sensor (see Wiring Diagram Technical Note, Mégane
II ph2, Scénic II ph2, Component code 1587).
Check the condition of the connector of the engine management computer (see Wiring Diagram Technical Note,
Mégane II ph2, Scénic II ph2, Component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the continuity, insulation and absence of interference resistance on the following connections:
– Connection code 3AAS between components 1587 and 120.
– Connection code 3AAT between components 1587 and 120.
– Connection code 3AAU between components 1587 and 120.
– Connection code 3AAV between components 1587 and 120.
– Connection code 3AAW between components 1587 and 120.
Check for + 12 V on the connector of the richness ratio sensor.
– Connection code 3FB of component 1587.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48
13B-200
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$104.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF980
PRESENT
OR
STOREDRICHNESS RATIO SENSOR FUNCTION
1.DEF: Above max threshold
2.DEF: Below minimum threshold
3.DEF: Signal incoherence
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the ignition has been switched on.
Special notes:
Use the bornier Elé. 1681 for all operations on the connectors of the injection
computer.
The richness ratio sensor is only present on certain F9Q818 engines. Check that the
vehicle is correctly equipped with this sensor.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
Check the condition of the connector of the richness ratio sensor (see Wiring Diagram Technical Note, Mégane
II ph2, Scénic II ph2, Component code 1587).
Check the condition of the connector of the engine management computer (see Wiring Diagram Technical Note,
Mégane II ph2, Scénic II ph2, Component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the continuity, insulation and absence of interference resistance on the following connections:
– Connection code 3AAS between components 1587 and 120.
– Connection code 3AAT between components 1587 and 120.
– Connection code 3AAU between components 1587 and 120.
– Connection code 3AAV between components 1587 and 120.
– Connection code 3AAW between components 1587 and 120.
Check for + 12 V on the connector of the richness ratio sensor.
– Connection code 3FB of component 1587.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
EDC16C36_V44_DF980/EDC16C36_V4C_DF980/EDC16C36_V48_DF980EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48