13B-371
AFTER REPAIRRepeat the conformity check in the interpretation of statuses and parameters
V9 MR-372-J84-13B450$170.mif
DIESEL INJECTION
Fault finding – Interpretation of commands13B
AC012DAMPER VALVE
NOTESCarry out this interpretation:
– after DF226 Damper valve
– or after a customer complaint (starting faults, poor performance).
Ignition on and engine stopped.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
Check the continuity, insulation and absence of interference resistance on the following connections:
– Connection code 3VN,
– Connection code 3VM,
between components 1461 and 120.
Check for +12 V on connection 3FB of component 1461.
Check for earth on connectionNT of component1461.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
With the vehicle ignition on, and the engine stopped:
Check that the damper valve is open.
If not, clean or replace the damper valve.
Actuate the valve using command AC012 and check the damper valve travel and the rest position of the valve.
Check the operation of the computer output stage with a voltmeter:
Actuate the valve with command AC012.
Positive lead to connection3FB and negative lead to connection3VN of component1461.
The voltmeter should display three cycles of ON-OFF (12.5 V then return to 0V).
If the measurement is correct, replace the damper valve.
If the measurement does not show any operation, contact the Techline.
EDC16C36_V44_AC012/EDC16C36_V4C_AC012/EDC16C36_V48_AC012/EDC16C36_V50_AC012/EDC16C36_V54_AC012/
EDC16C36_V58_AC012EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-372
AFTER REPAIRRepeat the conformity check in the interpretation of statuses and parameters
V9 MR-372-J84-13B450$170.mif
DIESEL INJECTION
Fault finding – Interpretation of commands13B
AC037PREHEATING RELAY
NOTESThis command is only run if fault DF025 Preheating unit diagnostic connection or
DF017 Preheating unit control circuit is present or stored and if no other fault is
present.
Ignition on and engine stopped.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
Before applying the following fault finding procedure, check that the battery voltage is not below 12 V.
Otherwise, recharge the battery.
Check the connections on the preheating unit, heater plugs and injection computer.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
Measure the resistance of the heater plugs. If this resistance is > 2 Ω, replace the defective plug(s).
Check the continuity and the absence of interference resistance on the following connections:
– Connection code 37AA between components257 and 681.
– Connection code 37AB between components 257 and 682.
– Connection code 37AC between components 257 and 683.
– Connection code 37AZ between components 257 and 680.
Check the condition of fuse FM12 (70 A) of the preheating unit supply. Replace it if necessary.
Then check for +12 V on connection BP35 of component 257.
Check the continuity, insulation, and the absence of interference resistance of the following connections:
– Connection code 3FF,
– Connection code 3FY,
Between components 257 and 120.
If the fault is still present, replace the pre-postheating unit.
EDC16C36_V44_AC037/EDC16C36_V4C_AC037/EDC16C36_V48_AC037/EDC16C36_V50_AC037/EDC16C36_V54_AC037/
EDC16C36_V58_AC037EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-373
AFTER REPAIRRepeat the conformity check in the interpretation of statuses and parameters
V9 MR-372-J84-13B450$170.mif
DIESEL INJECTION
Fault finding – Interpretation of commands13B
AC038LOW-SPEED FAN ASSEMBLY RELAY
NOTESThere must be no present or stored faults.
Perform this fault finding after an engine cooling fault or air conditioning fault.
Refer to the Wiring Diagram Technical Notes for the vehicle to locate the fuses and
relays concerned.
Ignition on and engine stopped.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
If the low speed fan assembly relay does not operate when command AC038 is run:
Check the low-speed fan assembly relay mounting and the connections of the engine management computer.
Check the fan assembly connections.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
If the fault is still present, check that the relay is actuated by the engine management computer as follows:
Disconnect the low-speed fan assembly relay, and fit a 50 to 100 Ω resistor on the relay mounting in place of the
coil, and connect a voltmeter as follows:
– positive terminal to +12 V battery,
– negative terminal to connection 3JN of component 336.
Run command AC038
If the voltmeter shows the battery voltage (4 ON-OFF cycles of 10 seconds), replace the relay.
If the low speed fan assembly relay is supplied using command AC038, but there is still a fan assembly activation
fault, check using the wiring diagram.
The conformity of the fan assembly FM15 maxi-fuse.
EDC16C36_V44_AC038/EDC16C36_V4C_AC038/EDC16C36_V48_AC038/EDC16C36_V50_AC038/EDC16C36_V54_AC038/
EDC16C36_V58_AC038EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-375
AFTER REPAIRRepeat the conformity check in the interpretation of statuses and parameters
V9 MR-372-J84-13B450$170.mif
DIESEL INJECTION
Fault finding – Interpretation of commands13B
AC039HIGH SPEED FAN ASSEMBLY
NOTESThere must be no present or stored faults:
Perform this fault finding after an engine cooling fault.
Refer to the Wiring Diagram Technical Notes for the vehicle to locate the fuses and
relays concerned.
Ignition on and engine stopped.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
If, when running command AC039, the high-speed fan assembly relay is not activated:
Check the high-speed fan assembly relay mounting and the connections of the engine management computer.
Check the fan assembly connections.
Repair if necessary.
If the fault is still present, check that the relay is actuated by the engine management computer as follows:
Disconnect the high speed fan assembly relay 335, fit a 50 to 100 Ω resistor on its mounting in place of the coil,
and connect a voltmeter as follows:
- positive terminal to +12 V battery,
- negative terminal to connection 3JP of component 335.
Run command AC039.
If the voltmeter shows the battery voltage (4 ON-OFF cycles of 10 seconds), replace the relay.
Disconnect the high speed fan assembly relay 337, fit a 50 to 100 Ω resistor on its mounting in place of the coil,
and connect a voltmeter as follows:
- positive terminal to +12 V battery,
- negative terminal to connection 3JP of component 337.
Run command AC039.
If the voltmeter shows the battery voltage (4 ON-OFF cycles of 10 seconds), replace the relay.
If the high-speed fan assembly relays are fed using command AC153, but there is still a fan activation fault, check
using the wiring diagram:
The conformity of the fan assembly FM15 maxi-fuse.
EDC16C36_V44_AC039/EDC16C36_V4C_AC039/EDC16C36_V48_AC039/EDC16C36_V50_AC039/EDC16C36_V54_AC039/
EDC16C36_V58_AC039EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-377
AFTER REPAIRRepeat the conformity check in the interpretation of statuses and parameters
V9 MR-372-J84-13B450$170.mif
DIESEL INJECTION
Fault finding – Interpretation of commands13B
AC103EGR BY-PASS
NOTESCarry out this fault finding procedure when the interpretation of fault DF304 EGR
bypass circuit has not been resolved.
Ignition on and engine stopped.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
Measure the resistance of the EGR bypass solenoid valve between the following connections:
– Connection code 3TP,
– Connection code 3FB,
of component 1301.
43 Ω to 49 Ω at +25°C.
32 Ω to 37 Ω at -40°C
If the resistance is not correct, replace the EGR by-pass solenoid valve.
Check the continuity, insulation and absence of interference resistance on the following connections:
– Connection code 3TP between components 1301 and 120.
– Connection code 3FB between components 1301 and 983.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
If you notice no valve movement when running command AC103, ensure that the computer output stage is
functioning:
Vehicle under + after ignition feed, clear the faults displayed by the diagnostic tool.
With the voltmeter in the direct current position:
With the EGR BY-PASS solenoid valve connected, connect the voltmeter earth lead to connection3TP of
component1301 and the positive lead to connection3FB.
Run command AC103, the voltmeter should display four successive readings which are approximately equal to
the 12 V battery voltage.
If the voltmeter indicates no control or a continuous voltage, contact the Techline.
If activation has run correctly, check the control vacuum:
– Disconnect the solenoid valve inlet hose and connect it to a pressure gauge.
– Start the engine and run it at a stable idle speed.
– If the vacuum pressure does not reach 800 mbar ± 100: check the vacuum pressure circuit from the vacuum
pump.
Repair if necessary.
EDC16C36_V44_AC103/EDC16C36_V4C_AC103/EDC16C36_V48_AC103/EDC16C36_V50_AC103/EDC16C36_V54_AC103/
EDC16C36_V58_AC103EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-381
AFTER REPAIRCarry out a road test followed by a complete check with the diagnostic tool.
V9 MR-372-J84-13B450$190.mif
13B
ALP1 No dialogue with engine management computer
STEP 1
Check the conformity of the vehicle type and the domain selected on the tool.
Check that the tool is not faulty by trying to establish dialogue with a computer on another vehicle.
Check the supply to the diagnostic socket:
+ Before ignition.
+ After ignition.
Earth.
Check (according to wiring diagram and equipment):
– The conformity of the after ignition fuse.
– The conformity of the injection relay mounting.
The conformity of the injection relay:
65 Ω ± 5 between the following connections:
– Connection code BP37 of component 983.
– Connection code 3AA of component 983.
infinite resistance between connections (open contact):
– Connection code BP37 of component 983.
– Connection code 3FB of component 983.
resistance < 0.2 Ω between the following connections (contact closed):
– Connection code BP37 of component 983.
– Connection code3FB of component983.
Disconnect the engine management computer and check that there are no conducting parts on the computer
studs. If this reveals any kind of impurity, rectify it and try to establish dialogue.
If the fault is still present, place the bornier Elé. 1681 on the engine harness:
Check for continuity and absence of interference resistance on the following multiplex connections:
– Connection code 133B between components 120 and 225.
– Connection code 133C between components 120 and 225.
Check for + 12 V on connections 3FB and AP29 of component 120.
Check for earth on connections NT of component 120.
A
EDC16C36_V44_ALP01/EDC16C36_V4C_ALP01/EDC16C36_V48_ALP01/EDC16C36_V50_ALP01/EDC16C36_V54_ALP01/
EDC16C36_V58_ALP01
DIESEL INJECTION
Fault finding – Fault Finding Chart
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58