AT-118
< SERVICE INFORMATION >
P0734 4GR INCORRECT RATIO
P0734 4GR INCORRECT RATIO
DescriptionINFOID:0000000005928158
• This malfunction will not be detected while the OD OFF indicator lamp is indicating another self-diagnosismalfunction.
• This malfunction is detected when the A/T does not shif t into fourth gear position or the torque converter
clutch does not lock up as instructed by the TCM. This is not caused by electrical malfunction (circuits open
or shorted) but by mechanical malfunction such as c ontrol valve sticking, improper solenoid valve operation,
malfunctioning oil pump or torque converter clutch, etc.
CONSULT-III Reference Value in Data Monitor ModeINFOID:0000000005928159
Remarks: Specification data are reference values.
On Board Diagn osis LogicINFOID:0000000005928160
• This is an OBD-II self-diagnostic item.
• Diagnostic trouble code “P0734 4GR INCORRECT RATIO” with CONSULT-III is detected when A/T cannot
be shifted to the 4GR position even if electrical circuit is good.
• This diagnosis monitors actual gear position by checki ng the torque converter slip ratio calculated by TCM
as follows:
Torque converter slip ratio = A x C/B
A: Output shaft revolution signal from output speed sensor
B: Engine speed signal from ECM
C: Gear ratio determined as gear position which TCM supposes
If the actual gear position is much lower than the pos ition (4th) supposed by TCM, the slip ratio will be much
less than normal. In case the ratio does not reach t he specified value, TCM judges this diagnosis malfunc-
tion.
This malfunction will be caused when shift solenoid valve A is stuck open or shift solenoid valve B is stuck
closed.
• Gear positions supposed by TCM are as follows.
In case of gear position with no malfunctions: 1, 2, 3 and 4 positions
In case of gear position with shift so lenoid valve A stuck open: 2, 2, 3 and 3* positions
In case of gear position with shift sol enoid valve B stuck closed: 1, 2, 2 and 1* positions to each gear position
above
*: “P0734 4GR INCORRECT RATIO” is detected.
Possible CauseINFOID:0000000005928161
• Shift solenoid valve A
• Shift solenoid valve B
• Line pressure solenoid valve
• Each clutch
• Hydraulic control circuit
DTC Confirmation ProcedureINFOID:0000000005928162
CAUTION:
• Always drive vehicle at a safe speed.
• If performing this “DTC Confirmation Procedure” again, always turn ignition switch OFF and wait at
least 10 seconds before continuing.
After the repair, perform the following proc edure to confirm the malfunction is eliminated.
Gear position123 4
Shift solenoid valve A ON (Closed)OFF (Open)OFF (Open)ON (Closed)
Shift solenoid valve B ON (Closed)ON (Closed) OFF (Open)OFF (Open)
Item name Condition Display value (Approx.)
LINE PRES DTY Small throttle opening (Low line pressure) ⇔
Large
throttle opening (High line pressure) 0%
⇔ 94%
Revision: May 2010 2011 Versa
P0740 TORQUE CONVERTERAT-123
< SERVICE INFORMATION >
DE
F
G H
I
J
K L
M A
B
AT
N
O P
P0740 TORQUE CONVERTER
DescriptionINFOID:0000000005928164
• The torque converter clutch solenoid valve is activated, with the gear in D4 and D3, by the TCM in response
to signals sent from the output speed sensor and t he ECM (throttle opening). Lock-up piston operation will
then be controlled.
• Lock-up operation, however, is prohibited when A/T fluid temperature is too low.
• When the accelerator pedal is depressed (less than 2/8) on lock-up condition, the engine speed should not
change abruptly. If there is an abrupt change in engine speed, there is no lock-up.
CONSULT-III Reference Val ue in Data Monitor ModeINFOID:0000000005928165
Remarks: Specification data are reference values.
On Board Diagnosis LogicINFOID:0000000005928166
• This is an OBD-II self-diagnostic item.
• Diagnostic trouble code “P0740 T/C CLUTCH SOL” with CO NSULT-III or 7th judgement flicker without CON-
SULT-III is detected when TCM detects an improper vo ltage drop while it tries to operate solenoid valve.
Possible CauseINFOID:0000000005928167
• Torque converter clutch solenoid valve
• Harness or connector
(The solenoid circuit is open or shorted.)
DTC Confirmation ProcedureINFOID:0000000005928168
CAUTION:
• Always drive vehicle at a safe speed.
• If performing this “DTC Confirmation Procedure” again, always turn ignition switch OFF and wait at
least 10 seconds before continuing.
After the repair, perform the following procedure to confirm the malfunction is eliminated.
WITH CONSULT-III
1. Turn ignition switch ON. (Do not start engine.)
2. Select “DATA MONITOR” mode for “TRANSMISSION” with CONSULT-III and wait at least 1 second.
3. Touch “START”.
4. Start engine and maintain the following conditions for at least 5 consecutive seconds. VEHICLE SPEED: 80 km/h (50 MPH) or more
THROTTLE POSI: 0.5/8 - 1.0/8
SLCT LVR POSI: “D” position
Driving location: Driving the vehic le uphill (increased engine load) will help maintain the driving
conditions required for this test.
5. If the check result is NG, go to AT-125, "
Diagnosis Procedure".
WITH GST
Follow the procedure “WITH CONSULT-III”.
WITHOUT CONSULT-III
1. Start engine.
2. Drive vehicle in D
1→ D2→ D3→ D4→ D4 lock-up position.
3. Perform self-diagnosis. Refer to AT-82, "
Diagnosis Procedure without CONSULT-III" .
4. If the check result is NG, go to AT-125, "
Diagnosis Procedure" .
Item nameCondition Display value (Approx)
TCC S/V DUTY Lock-up OFF ⇔ Lock-up ON 4% ⇔ 94%
Revision: May 2010 2011 Versa
P0740 TORQUE CONVERTERAT-125
< SERVICE INFORMATION >
DE
F
G H
I
J
K L
M A
B
AT
N
O P
Diagnosis ProcedureINFOID:0000000005928170
1.CHECK INPUT SIGNALWith CONSULT-III
1. Start engine.
2. Select “MAIN SIGNALS” in “DATA MONITOR” mode for “TRANSMISSION” with CONSULT-III.
3. Read out the value of “TCC S/V DUTY” while driving. Check the value changes according to driving speed.
Without CONSULT-III
1. Start engine.
2. Check voltage between TCM connector terminal and ground.
OK or NG
OK >> GO TO 5.
NG >> GO TO 2.
2.CHECK TORQUE CONVERTER CL UTCH SOLENOID VALVE CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect TCM connector.
3. Check resistance between TCM connector terminal and ground.
OK or NG
OK >> GO TO 5.
NG >> GO TO 3.
3. CHECK HARNESS BETWEEN TCM AND TERMINAL CORD ASSEMBLY HARNESS CONNECTOR
1. Turn ignition switch OFF.
2. Disconnect terminal cord assemb ly harness connector and TCM connector.
Monitor item Condition Display value
(Approx)
TCC S/V DUTY Lock-up OFF ⇔ Lock-up ON 4 % ⇔ 94 %
Name Connec-
tor Terminal
ConditionJudgement
standard
(Approx.)
To r q u e c o n -
verter clutch
solenoid
valve E31 3 - Ground When A/T performs lock-
up.
8 - 15 V
When A/T does not per-
form lock-up. 0 V
SCIA3261E
Solenoid Valve Connector Terminal Resistance (Approx.)
Torque converter clutch
solenoid valve E31 3 - Ground
5 - 20 Ω
SCIA3262E
Revision: May 2010 2011 Versa
AT-126
< SERVICE INFORMATION >
P0740 TORQUE CONVERTER
3. Check continuity between terminal cord assembly harness con-nector terminal and TCM connector terminal.
4. If OK, check harness for short to ground and short to power.
5. If OK, check continuity bet ween ground and transaxle assembly.
6. Reinstall any part removed.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
4.CHECK VALVE RESISTANCE
1. Turn ignition switch OFF.
2. Disconnect terminal cord assembly connector in engine room.
3. Check resistance between terminal cord assembly harness con- nector terminal and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair or replace damaged parts.
5.CHECK DTC
Perform AT-123, "
DTC Confirmation Procedure" .
OK or NG
OK >> INSPECTION END
NG >> GO TO 6.
6.CHECK TCM
1. Check TCM input/output signal. Refer to AT-75, "
TCM Terminal and Reference Value" .
2. If NG, recheck TCM pin terminals for damage or loose connection with harness connector.
OK or NG
OK >> INSPECTION END
NG >> Repair or replace damaged parts.
Component InspectionINFOID:0000000005928171
TORQUE CONVERTER CLUTCH SOLENOID VALVE
• For removal, refer to AT-222, "Control Valve Assembly and Accumulators" .
Resistance Check
ItemConnector Terminal Continuity
TCM E313
Ye s
Terminal cord assembly
harness connector F30
5
SCIA3263E
Solenoid valve Connector Terminal Resistance (Approx.)
Torque converter clutch
solenoid valve F30 5 - Ground 5 - 20
Ω
SCIA3456E
Revision: May 2010 2011 Versa
AT-128
< SERVICE INFORMATION >
P0744 TORQUE CONVERTER
P0744 TORQUE CONVERTER
DescriptionINFOID:0000000005928172
• This malfunction will not be detected while the OD OFF indicator lamp is indicating another self-diagnosismalfunction.
• This malfunction is detected when the A/T does not shif t into fourth gear position or the torque converter
clutch does not lock-up as instructed by the TCM. This is not caused by electrical malfunction (circuits open
or shorted) but by mechanical malfunction such as c ontrol valve sticking, improper solenoid valve operation,
malfunctioning oil pump or torque converter clutch, etc.
CONSULT-III Reference Value in Data Monitor ModeINFOID:0000000005928173
Remarks: Specification data are reference values.
On Board Diagn osis LogicINFOID:0000000005928174
• This is an OBD-II self-diagnostic item.
• Diagnostic trouble code “P0744 T/C CLUTCH FNCTN” wit h CONSULT-III is detected when A/T cannot per-
form lock-up even if electrical circuit is good.
• This diagnosis monitors actual gear position by checki ng the torque converter slip ratio calculated by TCM
as follows:
Torque converter slip ratio = A x C/B
A: Output shaft revolution signal from output speed sensor
B: Engine speed signal from ECM
C: Gear ratio determined as gear position which TCM supposes
If the actual gear position is much lower than the pos ition (4th) supposed by TCM, the slip ratio will be much
less than normal. In case the ratio does not reach t he specified value, TCM judges this diagnosis malfunc-
tion.
This malfunction will be caused when shift solenoid valve B is stuck closed.
• Gear positions supposed by TCM are as follows.
In case of gear position with no malfunctions: 1, 2, 3 and 4 positions
In case of gear position with shift solenoid valve B stuc k closed: 1, 2, 2 and 1* positions to each gear position
above
*: “P0744 T/C CLUTCH FNCTN” is detected.
Possible CauseINFOID:0000000005928175
• Line pressure solenoid valve
• Torque converter clutch solenoid valve
• Each clutch
• Hydraulic control circuit
DTC Confirmation ProcedureINFOID:0000000005928176
CAUTION:
• Always drive vehicle at a safe speed.
• If performing this “DTC Confirmation Procedure” again, always turn ignition switch OFF and wait at
least 10 seconds before continuing.
After the repair, perform the following proc edure to confirm the malfunction is eliminated.
WITH CONSULT-III
1. Start engine and select “DATA MONITOR” m ode for “TRANSMISSION” with CONSULT-III.
2. Touch “START”.
3. Make sure that output voltage of A/T fluid temperature sensor is within the range below.
FLUID TEMP SE: 0.4 - 1.5 V
If out of range, drive vehicle to decrease voltage (warm up the fluid) or stop engine to increase voltage
(cool down the fluid).
4. Select “TCC S/V FNCTN P0744” of “DTC & SR T CONFIRMATION” mode for “TRANSMISSION” with
CONSULT-III and touch “START”.
Item name Condition Display value (Approx)
TCC S/V DUTY Lock-up OFF ⇔ Lock-up ON 4% ⇔ 94%
Revision: May 2010 2011 Versa
P0745 PRESSURE CONTROL SOLENOID AAT-133
< SERVICE INFORMATION >
DE
F
G H
I
J
K L
M A
B
AT
N
O P
P0745 PRESSURE CONTROL SOLENOID A
DescriptionINFOID:0000000005928178
The line pressure solenoid valve regulates the oil pum p discharge pressure to suit the driving condition in
response to signals sent from the TCM.
The line pressure duty cycle value is not constant when the closed throttle po sition switch is ON. To
confirm the line pressure duty cycle at low-pressure, the accelerator (throttle) sh ould be open until the
closed throttle position switch is OFF.
CONSULT-III Reference Val ue in Data Monitor ModeINFOID:0000000005928179
Remarks: Specification data are reference values.
On Board Diagnosis LogicINFOID:0000000005928180
• This is an OBD-II self-diagnostic item.
• Diagnostic trouble code “P0745 PC SOLENOID A” with CO NSULT-III or 11th judgement flicker without CON-
SULT-III is detected when TCM detects an improper volt age drop while it tries to operate the solenoid valve.
Possible CauseINFOID:0000000005928181
• Harness or connector
(The solenoid circuit is open or shorted.)
• Line pressure solenoid valve
DTC Confirmation ProcedureINFOID:0000000005928182
CAUTION:
If performing this “DTC Confirmati on Procedure” again, always turn ignition switch OFF and wait at
least 10 seconds before continuing.
After the repair, perform the following procedure to confirm the malfunction is eliminated.
WITH CONSULT-III
1. Turn ignition switch ON and select “DATA MO NITOR” mode for “TRANSMISSION” with CONSULT-III.
2. Touch “START”.
3. Depress accelerator pedal completely and wait at least 1 second.
4. If the check result is NG, go to AT-135, "
Diagnosis Procedure" .
WITH GST
Follow the procedure “WITH CONSULT-III”.
WITHOUT CONSULT-III
1. Start engine.
2. With brake pedal depressed, shift the lever from “P” →“N” →“D” →“N” →“P” positions.
3. Perform self-diagnosis. Refer to AT-82, "
Diagnosis Procedure without CONSULT-III" .
4. If the check result is NG, go to AT-135, "
Diagnosis Procedure" .
Item nameCondition Display value (Approx.)
LINE PRES DTY Small throttle opening (Low line pressure)
⇔ Large
throttle opening (High line pressure) 0%
⇔ 94%
Revision: May 2010 2011 Versa
P0745 PRESSURE CONTROL SOLENOID AAT-135
< SERVICE INFORMATION >
DE
F
G H
I
J
K L
M A
B
AT
N
O P
Diagnosis ProcedureINFOID:0000000005928184
1.CHECK INPUT SIGNALWith CONSULT-III
1. Turn ignition switch ON. (Do not start engine.)
2. Select “MAIN SIGNALS” in “DATA MONITOR” mode for “TRANSMISSION” with CONSULT-III.
3. Read out the value of “LINE PRES DTY” while driv ing. Check the value changes according to driving
speed.
Without CONSULT-III
1. Turn ignition switch ON. (Do not start engine.)
2. Check voltage between TCM connector terminals and ground.
OK or NG
OK >> GO TO 5.
NG >> GO TO 2.
2.CHECK DROPPING RESISTOR
1. Turn ignition switch OFF.
2. Disconnect dropping resistor har ness connector in engine room.
3. Check resistance between terminals.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace damaged parts.
3.CHECK VALVE RESISTANCE
1. Turn ignition switch OFF.
2. Disconnect terminal cord assembly connector in engine room.
Item name Condition Display value
LINE PRES DTY Small throttle opening (Low line pressure)
⇔
Large throttle opening (High line pres-
sure) 0 % ⇔
94 %
Item Connec-
tor Terminal
Condition Judge-
ment stan- dard
(Approx.)
Line pres-
sure sole-
noid valve E31 1 - Ground When releasing accelera-
tor pedal after warming
up engine.
1.5 - 3.0 V
When depressing accel-
erator pedal fully after
warming up engine. 0 V
Line pres-
sure sole-
noid valve
(with drop-
ping resis-
tor) E31 2 - Ground When releasing accelera-
tor pedal after warming
up engine.
4 - 14 V
When depressing accel-
erator pedal fully after
warming up engine. 0 V
SCIA3267E
Item Connector Terminal Resistance (Approx.)
Dropping resistor E49 1 - 212 Ω
SCIA4950E
Revision: May 2010 2011 Versa
AT-136
< SERVICE INFORMATION >
P0745 PRESSURE CONTROL SOLENOID A
3. Check resistance between terminal cord assembly harness con-nector terminal and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace damaged parts.
4. CHECK HARNESS BETWEEN TCM AND TERM INAL CORD ASSEMBLY HARNESS CONNECTOR
1. Turn ignition switch OFF.
2. Disconnect terminal cord assembly harness connector and TCM connector.
3. Check continuity between terminal cord assembly harness con- nector terminal and TCM connector terminal.
4. Check continuity between terminal cord assembly harness con- nector terminal and dropping resistor harness connector termi-
nal.
5. Check continuity between dr opping resistor harness connector
terminal and TCM connector terminal.
6. If OK, check harness for short to ground and short to power.
7. If OK, check continuity bet ween ground and transaxle assembly.
8. Reinstall any part removed.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
5.CHECK DTC
Perform AT-133, "
DTC Confirmation Procedure" .
OK or NG
OK >> INSPECTION END
Solenoid valve Connector Terminal Resistance (Approx.)
Line pressure solenoid
valve F30 4 - Ground 2.5 - 5.0 Ω
SCIA3457E
Item
Connector Terminal Continuity
TCM E311
Ye s
Terminal cord assembly
harness connector F30
4
SCIA3272E
Item Connector Terminal Continuity
Dropping resistor harness
connector E49
2
Ye s
Terminal cord assembly
harness connector F30
4
SCIA7194E
Item Connector Terminal Continuity
TCM E312
Ye s
Dropping resistor harness
connector E49
1
SCIA7195E
Revision: May 2010 2011 Versa