Page 919 of 5598

CHG-6
< SYSTEM DESCRIPTION >
COMPONENT PARTS
SYSTEM DESCRIPTION
COMPONENT PARTS
Component Parts LocationINFOID:0000000006274858
Component DescriptionINFOID:0000000006274859
1. IPDM E/RRefer to PCS-4, "
Component Parts
Location". 2. ECM
Refer to EC-16, "
Component Parts
Location". 3. Battery current sensor
Refer to EC-16, "
Component Parts
Location".
4. Alternator 5. Combination meter (charge warning lamp)
Refer to MWI-6, "
METER SYSTEM :
Component Parts Location".
A. Engine room (RH)
JMMIA0411ZZ
Component part Description
Alternator (IC voltage regulator) IC voltage regulator controls the power generation voltage by the target power genera-
tion voltage based on the received power generation command signal.
When there is no power generation command signal, the alternator performs the normal
power generation according to the characteristic of the IC voltage regulator.
Battery current sensor Battery current sensor is installed to the battery cable at the negative terminal, and it de-
tects the charging/discharging current of the battery and sends the voltage signal to ECM
according to the current value.
Combination meter (C harge warning lamp) The IC voltage regulator warning function activates to illuminate the charge warning
lamp, if any of the following symptoms occur while alternator is operating:
Excessive voltage is produced.
No voltage is produced.
ECM Battery current sensor detects the charging/discharging current of the battery. ECM judg-
es the battery condition based on this signal.
ECM judges whether to perform the power generation voltage variable control according
to the battery condition.
When performing the power generation voltage variable control, ECM calculates the tar-
get power generation voltage according to the battery condition and sends the calculated
value as the power generation command value to IPDM E/R.
IPDM E/R IPDM E/R converts the received power generation command value into the power gen-
eration command signal (PWM signal) and sends it to the IC voltage regulator.
Revision: 2010 May2011 QX56
Page 920 of 5598
CHG
SYSTEMCHG-7
< SYSTEM DESCRIPTION >
C
DE
F
G H
I
J
K L
B A
O P
N
SYSTEM
CHARGING SYSTEM
CHARGING SYSTEM : System DiagramINFOID:0000000006274860
CHARGING SYSTEM : System DescriptionINFOID:0000000006274861
The alternator provides DC voltage to operate the vehi
cle's electrical system and to keep the battery charged.
The voltage output is controlled by the IC voltage regulator.
POWER GENERATION VOLTAGE VARIABLE CONTROL SYSTEM
POWER GENERATION VOLTAGE VARIABL E CONTROL SYSTEM : System Dia-
gram
INFOID:0000000006274862
POWER GENERATION VOLTAGE VARIABL E CONTROL SYSTEM : System De-
JPMIA0633GB
JPMIA0632GB
Revision: 2010 May2011 QX56
Page 921 of 5598
CHG-8
< SYSTEM DESCRIPTION >
SYSTEM
scription
INFOID:0000000006274863
By performing the power generation voltage variable c ontrol, the engine load due to the power generation of
the alternator is reduced and fuel consumption is decreased.
NOTE:
When any malfunction is detected in the power generat ion voltage variable control system, the power genera-
tion is performed according to the characteristic of the IC voltage regulator of the alternator.
Revision: 2010 May2011 QX56
Page 922 of 5598
CHG
CHARGING SYSTEMCHG-9
< WIRING DIAGRAM >
C
DE
F
G H
I
J
K L
B A
O P
N
WIRING DIAGRAM
CHARGING SYSTEM
Wiring DiagramINFOID:0000000006274864
JCMWM8336GB
Revision: 2010 May2011 QX56
Page 923 of 5598
CHG-10
< WIRING DIAGRAM >
CHARGING SYSTEM
JCMWM8337GB
Revision: 2010 May2011 QX56
Page 924 of 5598
CHG
CHARGING SYSTEMCHG-11
< WIRING DIAGRAM >
C
DE
F
G H
I
J
K L
B A
O P
N
JCMWM8338GB
Revision: 2010 May2011 QX56
Page 925 of 5598
CHG-12
< WIRING DIAGRAM >
CHARGING SYSTEM
JCMWM8339GB
Revision: 2010 May2011 QX56
Page 926 of 5598
CHG
DIAGNOSIS AND REPAIR WORKFLOWCHG-13
< BASIC INSPECTION >
C
DE
F
G H
I
J
K L
B A
O P
N
BASIC INSPECTION
DIAGNOSIS AND REPAIR WORKFLOW
Work FlowINFOID:0000000006274884
OVERALL SEQUENCE
DETAILED FLOW
JSMIA0009GB
Revision: 2010 May2011 QX56