PETROL INJECTION
Fault finding - Conformity check
17B
17B-125
PETROL INJECTION
Fault finding - Conformity check
17B
17B-125V9 MR-372-J84-17B050$470.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
FUEL CIRCUIT SUB-FUNCTION (continued 2):
NOTESOnly check the conformity after a complete check with the diagnostic tool. The values
shown in this conformity check are given as a guide.
Application conditions: Engine off, ignition on.
Order FunctionParameter or Status Checked
or ActionDisplay and notes Fault finding
6
RichnessPR138:Richness correctionIn loop mode, the
richness correction
corrects the injection
duration to obtain a
fuel mixture as close
as possible to a
richness of 1. The
richness correction
value varies around
50 between 0 and
100.
0
8ET056:Richness double loopINACTIVEIn the event of a fault,
apply the
interpretation of
ET056 Double
richness loop.
9
Oxygen sensorPR144:Self-adapting
richness offset0
used to detect any
tendency of the
injection system to
increase or decrease
the richness.
WITHOUT
10 PR143:Self-adapting
richness gain0
used to detect any
tendency of the
injection system to
increase or decrease
the richness.
11 Injection PR101:Duration of injection0µs
12Fuel
consumption.PR103:Instantaneous fuel
consumptionPR103 = 0 l/h
PETROL INJECTION
Fault finding - Conformity check
17B
17B-126
PETROL INJECTION
Fault finding - Conformity check
17B
17B-126V9 MR-372-J84-17B050$470.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
SUB-FUNCTION: FUEL CIRCUIT (continued 3):
NOTESOnly check the conformity after a complete check with the diagnostic tool. The values
shown in this conformity check are given as a guide.
Application conditions: Engine off, ignition on.
Order FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
13 Fuel pump ET047:Fuel pump
control circuitACTIVE for 1 second when the
ignition is switched on then
INACTIVEIf ACTIVE, apply
the interpretation
of DF085 Fuel
pump relay
control circuit
(when the +
after ignition
feed is turned
on, the pump
control circuit is
ACTIVE for
1 second then
becomes
INACTIVE).
14
IN LPG
ACTIVATED
MODEET561:Operating
modePetrol
Ignition on
In the event of a
fault, (see 17C,
3000 LPG
injection). 15 ET067:LPG readyWith LPG YESWithout LPG
NO by default
16 ET073:Conditions for
switching to
LPG modeWith LPG
AUTHORISEDWithout LPG
INHIBITED by
default
17 ET068:LPG tank
emptyWith LPG "NO"Without LPG
NO by default
18 ET066:LPG faultWith LPG "NO"Without LPG
NO by default
19 ET071:Transition
from petrol
mode to LPG
modeWith LPG
COMPLETEWithout LPG
COMPLETE by
default
20 ET072:Transition
from LPG
mode to petrol
modeWith LPG
IN PROGRESSWithout LPG
COMPLETE by
default
PETROL INJECTION
Fault finding - Conformity check
17B
17B-127
PETROL INJECTION
Fault finding - Conformity check
17B
17B-127V9 MR-372-J84-17B050$470.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
EMISSION CONTROL/OBD SUB-FUNCTION:
NOTESOnly check the conformity after a complete check with the diagnostic tool. The values
shown in this conformity check are given as a guide.
Application conditions: Engine off, ignition on.
Order FunctionParameter or Status Checked
or ActionDisplay and notes Fault finding
1
Oxygen sensorPR098:Upstream oxygen
sensor voltage50 mV < PR098
<800mVIn the event of a fault,
apply the
interpretation of
PR098 Upstream
oxygen sensor
voltage.
2 PR099:Downstream oxygen
sensor voltage50 mV < PR099
<800mVIn the event of a fault,
apply the
interpretation of
PR099 Downstream
oxygen sensor
voltage.
3
CanisterET050:Canister bleed
controlINACTIVEIn the event of a fault,
apply interpretation of
DF549 Canister
bleed circuit. 4 PR102:Canister bleed
solenoid valve OCR0%
Oxygen sensorAC018:Upstream O
2 sensor
heatingThe upstream
oxygen sensor
should heat upIn the event of a fault,
apply interpretation of
DF601 Oxygen
sensor heating
power circuit.
6AC019:Downstream O
2
sensor heatingThe downstream
oxygen sensor
should heat upIn the event of a fault,
apply interpretation of
DF602 Downstream
oxygen sensor
heating power
circuit.
PETROL INJECTION
Fault finding - Conformity check
17B
17B-128
PETROL INJECTION
Fault finding - Conformity check
17B
17B-128V9 MR-372-J84-17B050$470.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
EMISSION CONTROL / OBD SUBFUNCTION (cont.):
NOTESOnly check the conformity after a complete check with the diagnostic tool. The values
shown in this conformity check are given as a guide.
Application conditions: Engine off, ignition on.
Order FunctionParameter or Status Checked
or ActionDisplay and notes Fault finding
7
Oxygen sensorET052:Upstream O
2 sensor
heatingINACTIVEIn the event of a fault
apply the interpretation of
DF601 Upstream
oxygen sensor heating
power circuit.
8ET053:Downstream O
2
sensor heatingINACTIVEIn the event of a fault,
apply interpretation of
DF602 Downstream
oxygen sensor heating
power circuit.
9CanisterAC017:Canister bleed
solenoid valveThe canister
bleed solenoid
valve should be
heard running.In the event of a fault,
apply interpretation of
DF549 Canister bleed
circuit.
10
Fault findingET617:Upstream oxygen
sensor OBD fault
findingINACTIVE None
11 ET619:Fuel circuit OBD fault
findingINACTIVE None
12 ET581:Petrol combustion
misfire fault findingINACTIVE None
13 Fault finding ET340:Request by automatic
transmission to light
up the OBD warning
lightINACTIVEIf ACTIVE, apply the
interpretation of fault
DF099 Automatic
gearbox or sequential
gearbox connection via
the multiplex network.
14
RichnessET300:Richness regulationACTIVE
INACTIVEWITHOUT
15 ET056:Richness double loopACTIVE
INACTIVEIn the event of a fault,
apply the interpretation of
ET056 Double richness
loop.
PETROL INJECTION
Fault finding - Conformity check
17B
17B-129
PETROL INJECTION
Fault finding - Conformity check
17B
17B-129V9 MR-372-J84-17B050$470.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DRIVER PARAMETERS SUB-FUNCTION:
NOTESOnly check the conformity after a complete check with the diagnostic tool. The values
shown in this conformity check are given as a guide.
Application conditions: Engine off, ignition on.
Order FunctionParameter or Status Checked
or ActionDisplay and notes Fault finding
1
Motorised
throttleET051:Throttle stop
programmingCOMPLETED
Run command
RZ005
Programming. If the
parameters or
statuses are still not
correct, contact the
Techline. 2ET082:Motorised throttle
positionNo load
Full load
INTERMEDIATE
3 PR116:Motorised throttle
corrected position
setpointPR116 ≈ 2%
4 PR111:Motorised throttle
position corrected
valueNo load < 15 %
Full load >30%
5 PR097:Motorised throttle
lower stop
programmed value.5.96% < PR097
< 13.96%
6 PR096:Motorised throttle
upper stop
programmed value80%
position5% < PR429 < 25%
8 PR118:Measured throttle
position gang 1No load = 4 %
Full load = 99 %
Default value: 0%If there is a fault, use
the interpretation for
DF095 Throttle
potentiometer
circuit gang 1.
9 PR119:Measured throttle
position gang 2No load = 4 %
Full load = 100 %
Default value: 100%If there is a fault, use
the interpretation for
DF096 Throttle
potentiometer
circuit gang 2.
PETROL INJECTION
Fault finding - Conformity check
17B
17B-130
PETROL INJECTION
Fault finding - Conformity check
17B
17B-130V9 MR-372-J84-17B050$470.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
SUB-FUNCTION: DRIVER PARAMETERS (continued 1):
NOTESOnly check the conformity after a complete check with the diagnostic tool. The values
shown in this conformity check are given as a guide.
Application conditions: Engine off, ignition on.
Order FunctionParameter or Status Checked
or ActionDisplay and notes Fault finding
10Accelerator
pedal and
motorised
throttleET075:Pedal released and
throttle closedYESIf NO, apply the
interpretation for
PR030 Accelerator
pedal position
followed by the
interpretation for fault
DF079 Motorised
throttle valve servo
control.
11
Motorised
throttlePR597:Motorised throttle in
safe mode15% < PR597 < 25%Run command
RZ005
Programming. If the
parameters or
statuses are still not
correct, contact the
Techline. 12 PR593:Motorised throttle in
safe mode gang 1PR593 ≈ 1 V
13 PR594:Motorised throttle in
safe mode gang 2PR594 ≈ 1 V
14Accelerator
pedalET081:Accelerator pedal
positionNo load
Full load
INTERMEDIATEIn the event of a fault
apply the
interpretation for
PR030 Accelerator
pedal position
15Accelerator
pedalPR030:Accelerator pedal
positionNo load = < 16%
PF ≥85%In the event of a fault,
apply interpretation of
DF196 and DF198
Pedal sensor circuit
gangs 1 and 2, then
DF011 and DF012
Sensor supply
voltage 1 and 2.
PETROL INJECTION
Fault finding - Conformity check
17B
17B-131
PETROL INJECTION
Fault finding - Conformity check
17B
17B-131V9 MR-372-J84-17B050$470.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DRIVER PARAMETERS SUB-FUNCTION (continued 2):
NOTESOnly check the conformity after a complete check with the diagnostic tool. The values
shown in this conformity check are given as a guide.
Application conditions: Engine off, ignition on.
Order FunctionParameter or Status Checked
or ActionDisplay and notes Fault finding
16
Accelerator
pedal
(continued)PR568:Pedal position gang 10.2 V < PR568 < 5 V
Default value: 5 VIn the event of a fault,
apply the
interpretation of fault
DF196 Pedal sensor
circuit gang 1.
17 PR569:Pedal position gang 20.2 V < PR569 < 5 V
Default value: 0 VIn the event of a fault,
apply the
interpretation of fault
DF198 Pedal sensor
circuit gang 2.
18 PR147:Pedal potentiometer
voltage gang 1PR147≈ 15 VIn the event of a fault,
apply the
interpretation of fault
DF196 Pedal sensor
circuit gang 1.
19 PR148:Pedal potentiometer
voltage gang 2PR148≈ 7.5 VIn the event of a fault,
apply the
interpretation of fault
DF198 Pedal sensor
circuit gang 2.
20 PR424:Programming the no-
load position valuePR424≈ 15%Run command
RZ005
Programming. If the
parameters are still
not correct, contact
the Techline.
PETROL INJECTION
Fault finding - Conformity check
17B
17B-132
PETROL INJECTION
Fault finding - Conformity check
17B
17B-132V9 MR-372-J84-17B050$470.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
SUB-FUNCTION: DRIVER PARAMETERS (CONTINUED 3):
NOTESOnly check the conformity after a complete check with the diagnostic tool. The values
shown in this conformity check are given as a guide.
Application conditions: Engine off, ignition on.
Order FunctionParameter or Status Checked or
ActionDisplay and
notes Fault finding
21
Motorised
throttleAC027:Motorised throttleThe motorised
throttle should
be heard
operatingIn the event of a fault apply
the interpretation of
AC027 Motorised
throttle.
22 PR539:Measured throttle
voltage, gang
circuit 1PR539≈ 1 V
In the event of a fault,
apply interpretation of
DF095 Throttle
potentiometer circuit
gang 1 and DF096
Throttle potentiometer
circuit gang 2. 23 PR538:Measured throttle
voltage, gang circuit 2PR538≈ 0.4 V
24 PR587:Motorised throttle
lower stop gang 1PR587≈ 0.5 V
25 PR588:Motorised throttle
lower stop gang 2PR588≈ 0.5 V
26 PR589:Motorised throttle
upper stop gang 1PR589≈ 4.40 V
27 PR590:Motorised throttle
upper stop gang 2PR590≈ 4.40 VIn the event of a fault,
apply interpretation of
DF095 Throttle
potentiometer circuit
gang 1 and DF096
Throttle potentiometer
circuit gang 2. 28 PR113:Throttle lower stop
after applying. offsetPR113≈ 10%
29 ET0564:Type 1 defect modeNO
WITHOUT 30 ET0565:Type 2 defect modeNO
31 ET0566:Type 3 defect modeNO
32 ET0567:Type 4 defect mode
NO
33 ET0568:Type 5 defect modeNO
34 ET0569:Type 6 defect modeNO