PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-83
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-83V9 MR-372-J84-17B050$376.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF119
PRESENT
OR
STORED
CAMSHAFT SENSOR SIGNAL
1.DEF: Camshaft tooth event
2.DEF: Measurement of the offset outside permitted range of values
3.DEF: Tooth lost
4.DEF: Non-compliance with emission control standards
5.DEF: Programming the stops
6.DEF: Programming the initial stops
NOTESPriority when dealing with a number of faults:
Apply the procedure for dealing with faults DF046 Battery voltage or DF084
Actuators relay control circuit first if they are present or stored.
If faults DF119, DF154 Flywheel signal sensor circuit and DF080 Camshaft
dephaser circuit are present, ignore DF080 and deal with the other 2 faults first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after a road test.
Special note:
–K4M only.
– possibility of a slight lowering in performance
Check the cleanliness and condition of the camshaft sensor connections.
Check the cleanliness and condition of the camshaft sensor.
Repair if necessary.
If the fault is still present, check (with the ignition on) for + 12 V on track 3 of the camshaft sensor.
Check the insulation, continuity and the absence of interference resistance between the following
connections:
Injection computer, connectorB, track M2 track 3 of the camshaft sensor
Protection and Switching Unit, connectorCN,
track 2
Repair if necessary.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF119/S3000_V54_DF119
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-85
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-85V9 MR-372-J84-17B050$376.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF126
PRESENT
OR
STOREDPASSENGER COMPARTMENT HEATING RESISTOR
1.DEF: Multiplex network
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present when the ignition is switched on.
Run a multiplex network test (see 88B, Multiplexing).
If the fault is still present, carry out fault finding on the UCH (see87B, Passenger compartment connection unit).
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF126/S3000_V54_DF126
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-88
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-88V9 MR-372-J84-17B050$376.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF154
PRESENT
OR
STOREDFLYWHEEL SIGNAL SENSOR CIRCUIT
1.DEF: Abnormal voltage
2.DEF: Tooth lost
3.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
If faults DF154, DF119 Camshaft sensor circuit and DF080 Camshaft dephaser
circuit are present, ignore DF080 and deal with the other 2 faults first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the starter motor has been running for 10 seconds
or at an engine speed above 600 rpm.
Special note:
–the OBD warning light is lit,
– In the event of flywheel signal loss, the injection and ignition are cut off: the vehicle
stalls and cannot be restarted.
1.DEF
NOTESNone.
Check the cleanliness, condition and the fitting of the flywheel.
Repair if necessary.
If the flywheel has been replaced or removed, the flywheel target has to be reinitialised, then reprogrammed.
Programming reinitialisation:
Use command RZ005: Programming.
Carrying out the flywheel target programming:
– Decelerate a first time with injection cut-off (i.e. feet off the brake, accelerator pedal and clutch pedals) between
3500 and 3000 rpm, in 3rd gear for a manual gearbox and 2nd for automatic gearbox, for at least 5 seconds.
– Decelerate a second time with injection cut-off (i.e. brake, accelerator and clutch pedals released) between
2400and 2000 rpm for K4 engines and between 1800 and
1400 rpm for F4R engines, in 3rd gear for a manual gearbox and 2nd for an automatic gearbox, for at least
5 seconds.
After the operation, check that status ET089 Flywheel target programming is COMPLETED.
(*This is the moment when, during deceleration with no load, the engine drops to idle speed and recovers torque).
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF154/S3000_V54_DF154
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-94
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-94V9 MR-372-J84-17B050$423.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54PETROL INJECTION
Fault finding - Interpretation of faults
DF361
PRESENT
OR
STOREDCYLINDER 1 - 4 IGNITION COIL CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short-circuit to + 12 V
1.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
Deal with faults DF046 Battery voltage, DF084 Actuator relay control circuit or
DF085 Fuel pump relay control circuit first whether they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present with the engine running for 4 seconds at 600 rpm or
0.4 seconds at 6000 rpm.
Special note:
–the OBD warning light is lit,
–level 1 fault warning light on.
CC.0: The coil is continuously supplied, risk of destruction
CC.1: The coil is not supplied, injection cut-off on cylinders 1 and 4, destruction of the
catalytic converter possible and prevention of On board diagnostics.
Disconnect the connector from the pencil coil of cylinders 1 and 4.
Check the cleanliness and condition of the pencil coils and their connections.
Repair if necessary.
Measure the primary and secondary resistance of the cylinder 1 pencil coil.
Replace the cylinder 1 coil if the primary resistance is not 540 mΩ ±30mΩ or the secondary resistance is not
10.7 kΩ ± 1.6 kΩ (K4 engines).
Replace the cylinder 1 coil if the primary resistance is not 520 mΩ ±50mΩ or the secondary resistance is not
6.7 kΩ ± 0.67 kΩ (F4 engines).
Switch off the ignition and disconnect the injection computer.
Check the cleanliness and condition of the connections.
Repair if necessary.
Use the "Universal bornier" to check the insulation and continuity of the following connections:
Injection computer, connector C, track M4 track 2 of coil 1
Coil 4 track 2 track 1 of coil 1
If the fault is still present, replace the faulty pencil coil.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF361/S3000_V54_DF361
MR-372-J84-17B050$423.mif
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-95
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-95V9 MR-372-J84-17B050$423.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF361
CONTINUED
Check for the + 12 V feed on track 1 of the cylinder 4 pencil coil connector with the ignition on.
If +12V is not present:
Switch off the ignition,
– disconnect the connectorMN in the Protection and Switching Unit,
– check the cleanliness and condition of the connections,
– using the Universal bornier, check the continuity on the following connection:
Protection and Switching Unit connector MN,
track 9track 1 of the pencil coil for cylinder 4
Reconnect the Protection and Switching Unit connector.
With the ignition on, if the +12V feed is still not present on the cylinder 4 coil connector, there is a fault with the
Protection and Switching Unit.
Contact the Techline.
Check the operation of the fuel pump relay using command AC079 Actuator static test.
Deal with fault DF085 Fuel pump relay control circuit if it is present or stored after the command is activated.
If the fault is still present, replace the faulty pencil coil.
If the fault is still present, deal with the other faults then proceed with the conformity check.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-96
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-96V9 MR-372-J84-17B050$423.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF362
PRESENT
OR
STOREDCYLINDER 2 - 3 IGNITION COIL CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short-circuit to + 12 V
1.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
Deal with faults DF046 Battery voltage, DF084 Actuator relay control circuit or
DF085 Fuel pump relay control circuit first whether they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present with the engine running for 4 seconds at 600 rpm or
0.4 seconds at 6000 rpm.
Special note:
–the OBD warning light is lit,
–level 1 fault warning light illuminated.
CC.0: The coil is continuously supplied, risk of destruction.
CC.1: The coil is not supplied, injection cut-off on cylinders 2 and 3, destruction of the
catalytic converter possible and inhibition of OBD fault finding.
Disconnect the connector from the pencil coils of cylinders 2 and 3.
Check the cleanliness and condition of the pencil coils and their connections.
Repair if necessary.
Measure the primary and secondary resistance of the cylinder 2 pencil coil.
Replace the cylinder 2 coil if the primary resistance is not 540 mΩ ±30mΩ or the secondary resistance is not
10.7 kΩ ± 1.6 kΩ (K4 engines).
Replace the cylinder 2 coil if the primary resistance is not 520 mΩ ±50mΩ or the secondary resistance is not
6.7 kΩ ± 0.67 kΩ (F4 engines).
Switch off the ignition and disconnect the injection computer.
Check the cleanliness and condition of the connections.
Repair if necessary.
Use the "Universal bornier" to check the insulation and continuity of the following connections:
Computer, connectorC, track M3 track 2 of coil 2
Coil 3 track 2 track 1 of coil 2
If the fault is still present, replace the faulty pencil coil.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF362/S3000_V54_DF362
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-97
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-97V9 MR-372-J84-17B050$423.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF362
CONTINUED
Check for the + 12 V feed on track 1 of the cylinder 3 pencil coil connector with the ignition on.
If there is no + 12V:
Switch off the ignition,
– disconnect the MN connector in the Protection and Switching Unit,
– check the cleanliness and condition of the connections,
– using the universal bornier, check for continuity on the following connection:
Protection and Switching Unit connector MN,
track 9track 1 of the cylinder 3 pencil coil
Reconnect the Protection and Switching Unit connector.
If the +12V feed is still not present on the connector of the cylinder 3 coil, there is a fault in the Protection and
Switching Unit.
Contact the Techline.
Check the operation of the fuel pump relay using command AC079 Actuator static test.
Deal with fault DF085 Fuel pump relay control circuit if it is present or stored after the command is activated.
If the fault is still present, replace the faulty pencil coil.
If the fault is still present, deal with the other faults then proceed with the conformity check.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-102
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-102V9 MR-372-J84-17B050$423.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF410
PRESENT
OR
STOREDINSTRUMENT PANEL CONNECTION
1.DEF: Multiplex line connection fault
NOTESSpecial note:
– Cruise control/Speed limiter deactivated.
–OBD warning light not illuminated when ignition switched on.
Run a multiplex network test (see88B, Multiplexing).
If the fault is still present, carry out fault finding on the Instrument panel system (see83A, Instrument panel).
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF410/S3000_V54_DF410