DIESEL INJECTION
Fault finding – Conformity check13B
13B - 155V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM NO.: C1
Vdiag No.: 51
AIR CIRCULATION (TURBOCHARGING/INLET) (CONTINUED)
*Opening cyclic ratio signal
NOTESOnly check conformity after a complete check using the diagnostic tool. The values
shown in this conformity check are given as a guide.
Test Conditions: ENGINE AT IDLE SPEED, COOLANT TEMPERATURE > 80 ˚C.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
4Air circulationPR035:Atmospheric
pressureIndicates the
atmospheric pressure
in mbar. The sensor is
built into the computer.
Default value:
750 mbar.In the event of a fault,
consult the interpretation
of DF003 Atmospheric
pressure sensor circuit.
PR132:Air flow25 < X < 50 kg/hIn the event of a fault,
consult the interpretation
of parameter DF056 Air
flow sensor circuit.
PR672:Damper valve
position setpointX < 5 %
In the event of a fault,
consult the interpretation
for fault DF226 Damper
valve circuit. PR417:OCR inlet air flapX < 5 %
PR420:Damper valve
error counterX = 0
5Sensor feedPR081:Inlet temperature
sensor voltage1.90 < X < 2.90 V
Safe value: 5 VIn the event of a fault, refer
to the interpretation of
fault DF039 Inlet air
temperature sensor
circuit.
PR079:Atmospheric
pressure sensor
voltage3.80 < X < 4 VIn the event of a fault,
consult the interpretation
of DF003 Atmospheric
pressure sensor circuit.
PR073:Air flowmeter
feed voltage1.5 < X < 2.5 V
Safe value: 0 VIn the event of a fault, refer
to the interpretation of
fault DF013 Sensor feed
voltage no. 3
DIESEL INJECTION
Fault finding – Conformity check13B
13B - 157V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM NO.: C1
Vdiag No.: 51
FUEL CIRCUIT (continued)
NOTESOnly check conformity after a complete check using the diagnostic tool. The values
shown in this conformity check are given as a guide.
Test Conditions: ENGINE AT IDLE SPEED, COOLANT TEMPERATURE > 80 ˚C.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
4FlowPR017:Fuel flowX = 0 < X < 60 mg/stNone
PR157:Fuel flow setpointPR017 = PR157None
PR364:Cylinder no. 1
fuel flow
correction
± 1 mg/stIn the event of a fault, refer
to the interpretation of
test 8: POOR INJECTOR
OPERATION. PR405:Cylinder no. 2
fuel flow
correction
PR406:Cylinder no. 3
fuel flow
correction
PR365:Cylinder no. 4
fuel flow
correction
5Rail currentPR007:Rail pressure
regulator current
setpointX = 1400 ± 50 mA
Default value:
1600 mAIn the event of a fault,
consult the interpretation
of fault DF007 Rail
pressure sensor circuit.
PR006:Rail pressure
regulator currentX = PR007 ± 5 mA
Default value:
1600 mA
PR080:Rail pressure
sensor voltage1 < X < 1.5 V
Safe value: 5 VIn the event of a fault, refer
to the interpretation of
fault DF013 Sensor feed
voltage no. 3