2009 CHERY TIGGO relay

[x] Cancel search: relay

Page 484 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine Diagnostic Procedure
1.CHECK GROUND CONNECTIONS
• Turn ignition switch off.
• Loosen and retighten ground screws on the body (See Ground In

Page 511 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine 2.0L ENGINE CONTROLS
GENERAL INFORMATION03-229
Description 03-229
Operation 03-229
Electronic Engine Control Input & Output
Device Failure Mode

Page 513 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine GENERAL INFORMATION
Description
The Engine Control Module (ECM) utilizes integrated circuitry and information carried on the Controller Area Ne

Page 529 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine ECM Connector Pin-Out Table
ECM PIN-OUT TABLE
PINCIRCUIT IDENTIFICATION PINCIRCUIT IDENTIFICATION
1 (With EOBD)
42Intake Air Temperature Sensor

Page 536 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine DTCDTC DEFINITION
P0537 A/C Evaporator Temperature Sensor Circuit Low
P0538 A/C Evaporator Temperature Sensor Circuit High
P0560 System Voltage

Page 539 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine Check reference values between ECM terminals and ground under the following conditions:
ECM Power Supply Circuits
TERMINAL NO.ITEMCONDITIONDATA

Page 542 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine 3.DETECT MALFUNCTIONING PART
•  Check the following:
� Harness connectors C-103, E-103, terminal 14
� Front fuse and relay box connector A
�

Page 543 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine 7.CHECK ECM POWER SUPPLY CIRCUIT - (2)
•  Turn ignition switch on and then off.
•  Check voltage between ECM terminals 44, 45, 63
 and grou