Downloaded from www.Manualslib.com manuals search engine •Check for harness continuity between the following terminals:
• Continuity should exist.
BODY FUSE
AND RELAY BOX
TERMINAL IMMOBILIZER
CONTROLMODULE
TERMINAL CONTINUITY
A6
4Yes
• Check harness for a short to ground.
• Continuity between Immobilizer control module power supply and ground should not exist.
Is the check result normal?
Ye s>>Go to the step 7.
No
>>Repair or replace the open or high resistance circuit or short to ground in harness or connectors.
6.CHECK IMMOBILIZER CONTROL MODULE POWER SUPPLY CIRCUIT
• Turn ignition switch off.
• Disconnect the negative battery cable.
• Disconnect the body fuse and relay box electrical connector A.
• Check the resistance between Immobilizer control module ignition switch circuit terminal 4 and Immobilizer con-
trol module battery supply circuit terminal 1.
IMMOBILIZER
CONTROLMODULE
TERMINAL IMMOBILIZER
CONTROLMODULE
TERMINAL CONTINUITY
14N
o
• Check resistance between Immobilizer control module ignition switch circuit and other power circuits.
Is the check result normal?
Ye s>>Go to the step 8.
No
>>Repair or replace short to power circuits in harness or connectors.
DIAGNOSIS & TESTING
15–130Chery Automobile Co., Ltd.